1 / 13

E94-107: Hypernuclei Status Report Francesco Cusanno Hall A collaboration meeting, May 17-18, 2004

E94-107: Hypernuclei Status Report Francesco Cusanno Hall A collaboration meeting, May 17-18, 2004. E94-107: high resolution hypernuclei spectroscopy program on 1p-shell nuclei M ain goal : L N interaction S eptum magnets commissioned on December RICH added to the hadron PID system

Download Presentation

E94-107: Hypernuclei Status Report Francesco Cusanno Hall A collaboration meeting, May 17-18, 2004

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. E94-107: Hypernuclei Status Report Francesco Cusanno Hall A collaboration meeting, May 17-18, 2004 E94-107: high resolution hypernuclei spectroscopy program on 1p-shell nuclei • Main goal: LN interaction • Septum magnets commissioned on December • RICH added to the hadron PID system • Data taking: January 13 – 28 and April 17 – May 17 • Collected charge: 49.6 Coulomb on 12C and 56.1 Coulomb on 9Be, one day on Hydrogen

  2. Hypernuclear High Resolution Spectroscopy E-94-107 F. Garibaldi, S. Frullani, J. LeRose, P. Markowitz, T. Saito e + AZ -> e’ + K+ + A(Z -1)L VLN = V( r ) + Vs( r ) SL.SN + VL(r ) SN.lNL + VT( r) S12 nb/sr2/GeV 10 15 20 5 Electron scattering angle Cross section

  3. The targets 12C: comparison with present data, better understanding of the data with hadronic probes and Hall C E89-009 (additional peak(s) found respect to predictions) 9Be: spin doublets, s-s potential parameter clarification. The next goals: 7Li: large neutron excess 16O: ground state doublet investigation, ‘original’ target The kinematics Ei = 4.016 GeV, 3.777 (3.775) GeV Pk= 1.98 GeV/c, 1.96 GeV/c Pe= 1.80 GeV/c, 1.56 GeV/c

  4. On-line ‘observations’ • Cross sections on nuclei are smaller than expected • The background is smaller than expected and it is very strongly reduced by the PID system. The resulting contamination on the missing energy spectrum is very small. The absence of contamination and the good resolution allow a good spectroscopy also with the real counting rate. • The missing energy spectrum could be strongly improved by a ‘event-by-event’ evaluation of the beam central energy

  5. Main Results 12C • Run Time: • January 9 – 27 and April 18 – 25 • Number of Runs Analyzed 198 (January) + 214 (April, runs from 2524 up to 2777) Total Charge: • Accumulated 49.6 Coulomb; different sets of data: RICH, kinematics, beam energy • 1 Coulomb @ 100 mA are 2.8 hours = 5.79 effective days (2.71 + 3.08)

  6. Total Counts • 700 Total ground-state counts, background subtracted; • Background counts = 1.1 counts / MeV x Coulomb (RICH); • 700 Counts in the g. s. peak = 14.1 counts / Coulomb; Not all of the data here! background

  7. Performance • The ground state and the p-shell state are identified with a good statistics • Indication of core-excited states and p-shell state (confirmation of Hall C E89009 data?). • The reduction factor with respect to the expected counting rate is 7.0 – 7.5. • The energy resolution is ‘under investigations’ 800 keV 1.5 MeV MeV MeV MeV Much better? Run # MeV

  8. Main Results 9Be • Run Time: • Started on 26 April Owl shift; • Runs Analyzed on 11 April 8.00 am, 16 Days. • Number of Runs Analyzed 435 from 2779 up to 3445. • Total Charge: • Accumulated 56.1 Coulomb; • 1 Coulomb @ 100 mA are 2.8 hours = 6.54 effective days; • Beam Efficiency 41%;

  9. Total Counts • 1050 Total Counts no background subtracted; • 400 Background counts = 7.1 counts / Coulomb; • 650 Counts in the peak = 11.6 counts / Coulomb;

  10. Performance • The reduction factor with respect to the expected counting rate is 6.5 (a bit better than C?) . • The resolution is improved 0.8 MeV (FWHM) with respect to the C data but is still poor for a correct identification of the peaks.

  11. Present and Future Work • Beam energy correction with EPICS variables (thanks Ole) • Optimized Coincidence Time calculation (thanks Rob) • Data normalization (thanks Bob) • Fine tuning of the RICH code • optics database (thanks Doug and Yi) • Beam incident angle, raster

  12. Conclusions We have just completed the data taking (yesterday) • On-line results are promising. The 12C data seem confirm the data from Hall C, The 9Be data show a interesting structure that would confirm the expected spectrum • Optics database optimized for missing mass reconstruction, the obtained resolution on optics data is excellent • We are presently working on the missing mass calculation, very probably the present resolution is affected by a not optimized correction on the beam energy value • The analysis is continuouslygoing forward, to obtain ‘publishable’ results ASAP (at least for my theses :-D).

  13. THANKS The experiment was proposed in 1994! Now we have just ended the data taking and we start to see nice results. Many people have done a strong effort to realize it. THANK YOU VERY MUCH !!!

More Related