Egham Water Treatment Works. Flow: 2920 m 3 /h. Source. Thames River. Screening. With surface boom. Rotating Mesh Screen. Debris from Screens. Pre-ozone in-line injector. Purpose: to help with coagulation They also add pre chlorine to breakpoint any ammonia needed ~80% of time?.

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about 'Egham Water Treatment Works' - kayleen


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
source
Source
  • Thames River
screening
Screening
  • With surface boom
pre ozone in line injector
Pre-ozone in-line injector
  • Purpose: to help with coagulation
  • They also add pre chlorine to breakpoint any ammonia
    • needed ~80% of time?
pre o3 injector and static mixer
4 elements

700 mm diameter

196 mbar headloss

97% transfer efficiency

Pre-O3 injector and static mixer
gravity settling tanks
Gravity Settling Tanks
  • Sludge blanket
  • submerged conical sludge collectors
    • can be barely seen here
    • suspended from above
dual media rapid filters
Dual Media rapid filters
  • Anthracite & Sand
  • siphons (good practice)
lox handling
LOX handling
  • Heat transfer
ozone generator
Ozone Generator
  • Trailigaz
  • One of 3 units
    • only one in use that day
ozone generator19
Ozone Generator
  • No blue glow, because of pure O2
intermediate o3 monitor
Intermediate O3 Monitor
  • Purpose of inter ozone: disinfection
  • criteria: 0.4 mg/L residual after 4 minutes in contact tank
gac contactors
GAC contactors
  • Modular design
  • Avoided need for expensive in place concrete
    • problems with leaks
final disinfection
Final Disinfection
  • Free chlorine
    • shoot for a residual of about 0.5 mg/L
    • requires a dose of ~ 2-3 mg/L
  • Addition of sulfur dioxide
    • to achieve target FRC
  • THMs are low (~30 ug/L)
    • except when prechlorinating
    • final pH is about 7