TheBeam Conditions Monitor at ATLAS experiment

38 cm. 183cm. 1 st 2 nd stage. Amplifier schematic. Amplifier in module box. Non-irradiated/irradiated Agilent FE comparison. Si diode signal Si diode noise Gali-52 amplification. Fotec FE (500 MHz) 200 MHz BWL.

joey
Download Presentation

TheBeam Conditions Monitor at ATLAS experiment

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 38 cm 183cm 1st 2nd stage Amplifier schematic Amplifier in module box Non-irradiated/irradiated Agilent FE comparison Si diode signal Si diode noise Gali-52 amplification Fotec FE (500 MHz) 200 MHz BWL S/N ~ 7.5:1 S/N ~ 9.2:1 Typical MIP pulse 44 m BCM modules ATLAS BCM Pixel Sensor in module box ~100 kRad Sensor with Au test metallization ~100 m ~15 m electronics cavern ATLAS PP2 ~30 MRad Signal processing schematics ATLAS PIXEL MIP Back-to-back diamonds at 45° TheBeam ConditionsMonitor at ATLAS experiment V. Cindro1, I. Dolenc1, H. Kagan5, G. Kramberger1, H. Frais-Kölbl4, A. Gorišek2, E. Griesmayer4, I. Mandić1, M.Meyer, M. Mikuž1, H. Pernegger2, W. Trischuk3, P. Weilhammer2, M. Zavrtanik1 1Univ. Ljubljana / Jožef Stefan Institute, Ljubljana, Slovenia, 2CERN, Geneva, Switzerland, 3University of Toronto, Toronto, Canada, 4Fotec, Wiener Neustadt, Austria, 5Ohio State University, Columbus, USA Abstract The Beam Conditions Monitor at ATLAS experiment is being developed as a stand-alone device allowing to measure background events induced either on beam gas interactions or by beam accidents, for example beam hitting at the collimators upstream the spectrometer. This can be achieved by measuring signals in two stations placed symmetric around the interaction point. The 25 ns repetition of collisions poses stringent requirements on the timing resolution. The optimum separation between collision and background events is 12.5 ns implying a distance of 1.9m from the interaction point. Pulses less than 3 ns wide are required with 1 ns rise time and baseline restoration in 10 ns. Combined with the radiation field of 1015 hadrons/cm2 in 10 years of LHC operation only diamond detectors are considered suitable for this task.Polycrystalline CVD diamond pad detectors of 1 cm2 and around 500 μm thickness were assembled with a two-stage RF amplifier and tested in testbeams at MGH in Boston , SPS pion beam at CERN and pion beam at KEK. To increase the S/N ratio two back-to-back diamonds were read out by a single amplifier. Limiting the bandwidth at the readout to 200 MHz provided further improvement; S/N ratio of about 8:1 could be achieved with MIP's. Inclining detectors to 45 degrees with respect to the beam further increases the S/N ratio. Amplifiers of the two stages were irradiated with protons and neutrons to 1015 particles/cm2. Evaluating the irradiated electronics with silicon pad diodes, 20 % degradation in S/N ratio was observed. Ten detector modules are being assembled and tested at CERN for their final installation into the ATLAS pixel support structure in the mid of 2006. • Goals • Provide distinctive signature of beam anomalies in ATLAS such as • Beam scraping at TAS collimators • Beam gas interactions • Stand alone device providing information about genuine interactions • Monitoring of interactions at LHC start-up • Luminosity assessment • Front-end electronics • Two stage Fotec HFK500 amplifier • 1st stage: 500 MHz Agilent MGA-62563 GaAs MMIC low noise amplifier (A = 22 dB, NF = 0.9 dB) • 2nd stage: Mini Circuits Gali-52 InGaP HBT broad-band micro-wave amplifier (A = 20 dB) • Amplifiers tested for radiation hardness • Up to 1015/cm2 reactor neutrons and protons from CERN PS • Agilent: ~ 20 % amplification loss observed with Si diodes, no noise increase • Gali-52: 0.5 dB amplification loss • FE amplifier OK for BCM application • Working principle • Distinguish interactions from background via time of flight • With two symmetric stations at ±Δz/2 • Interactions: in time • Background: out of time on one side by Δt = Δz/c • At high luminosity expect about one hit for each bunch crossing • Interactions at Δt = 0, 25, 50 … ns • Optimally distinguished background at Δt = 12.5 ns ⇒ Δz = 3.8 m 2 detector stations, symmetric in z X TAS events: Δ Interactions: t=0, 25 ns, 50ns .. • BCM module tests • Beam test at MGH Boston • Proton beam 200 MeV and 125 MeV • Signal ≥ 2.3 MIPs • Single and back-to-back sensors at 0 and 45° • Signal increase 0->45° by ~ √2 • Signal increase in double-decker by 2, noise by 1.3 • Bench tests • 30 MBq 90Sr source; ~ MIPs signal • QA for BCM modules • Module stability tests • Noise independent of HV • Good reproducibility of signals • Signal stable to 4 % during 24 h, longer tests running • Beam test at CERN SPS • SPS H8 pion beam – MIPs signal • with 16 m of cable:S/N (most probable) ~ 7.5:1 • Timing: difference between two stations 2.7 ns FWHM • Improved to 9.2:1 by implementing 200 MHz BWL on scope • Requirements • Fast signals • Rise-time ~ 1 ns • Width ~ 3ns • Base line restoration in ~ 10 ns to prevent pile-up • Single MIP sensitivity • S/N ~ 8 for perpendicular MIP before irradiation • Installation close to the beam pipe at large η • Radiation hardness up to 50 MRad and 1015π/cm2 • No maintenance – robust detector Back-to-back Single diamond • Realization • Two stations with four detector modules each • Mounted on pixel support structure at z = ±183.8 cm • Sensor at r ~ 55 mm, about 20 mm from the beam pipe 0° single double 45° • Beam test at KEK • Few GeV/c pion beam • Signal/noise ~13 at 45o • Noise occupancy measurement • Sensors • Polycrystalline CVD diamond sensors chosen • Radiation hard – shown to work at > 1015 particles/cm2 • Fast signals – high velocity and cut-off due to trapping • Small leakage current – no cooling required • Procurement in collaboration with CERN RD-42 • Sensors produced and conditioned by Element Six Ltd. • Metallized with proprietary radiation hard process at OSU • Sensor properties • Size 10 mm x10 mm, active 8 mm x 8 mm (metallization) • Thickness ~500 μm • Charge collection distance ~220 μm • Holds ~ 2 V/ μm, operating voltage 1000 V, current ~ nA • Sensor assembly – two sensors back-to-back at 45° to increase signal • NINO amplifier-discriminator tests • Differential timing amplifier-discriminator (1 ns peak, 25 ns jitter) • LVDS output with width proportional to time-over-threshold • Radiation tolerant design by CERN-MIC • Signal split 1:12 into two inputs to increase dynamic range • Tests confirm suitability as BCM back-end chip Signal Noise NINO count-rate vs. threshold for noise / signal & noise

More Related