1 / 25

ICANS-XVIII

ICANS-XVIII. A position sensitive transmission detector for epithermal neutron imaging. E. M. Schooneveld and Ancient Charm partners. Content. Introduction Principle Construction Measurements Conclusions Future. Introduction. ANCIENT CHARM EU funded FP6 project, contract 015311

joanne
Download Presentation

ICANS-XVIII

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ICANS-XVIII A position sensitive transmission detector for epithermal neutron imaging E. M. Schooneveld and Ancient Charm partners

  2. Content • Introduction • Principle • Construction • Measurements • Conclusions • Future

  3. Introduction • ANCIENT CHARM • EU funded FP6 project, contract 015311 • Goal: 3D imaging of cultural heritage (archaeological) objects. • Archaeologists want to know elemental and phase composition of object. • Want to look inside object  imaging

  4. Introduction • Available techniques • Phase, structure texture analysis: • Neutron diffraction. • Element analysis: • Delayed Gamma Activation Analysis (DGAA) • Prompt Gamma Activation Analysis (PGAA) • Neutron Resonant Capture Analysis (NRCA)

  5. Introduction • Imaging techniques: • Neutron tomography (NT) • Neutron diffraction tomography (NDT) • Prompt Gamma Neutron Activation Imaging (PGAI) • Neutron Resonance Capture Imaging (NRCI) • Neutron Resonance Transmission (NRT) • Our detector transmission neutron detector  NRT

  6. Introduction • Pros: • Native imaging (2D detector) no scanning pencil beam • “4 solid angle coverage” • Elemental analysis • Structural analysis ? • Cons: • Small dips on high baseline  need good statistics + good baselineestimation • Position resolution limited to ~1mm • Need low beam divergence or detector close to sample

  7. Principle Neutron Detector beam • Estimated data collection time: ~1 hr per 2D image  ~1 day per tomograph.

  8. Principle • Element identification by resonant neutron absorption. • Need resonance in right energy range

  9. Principle • Periodic system with indications for suitability of NRT (regions were lowest resonance occurs)

  10. 16 channel PMT GS20 glass scintillators 1.8mm * 1.8mm * 9mm Optical fibres (4 per pixel) Construction • Detector • Made 16 pixel prototype to get experience with assembly and test performance. • Pixels: 4 * 4 array with 2.5mm pitch  10mm * 10mm active area.

  11. Construction • Monte Carlo simulations (GEANT4) • Issues: Type of optical fibre + scintillator support. • Cross-talk: • Made prototype with plastic fibres and BN scintillator support.

  12. Construction • Photos

  13. Construction

  14. Measurements • Measurements on INES beam line at ISIS • DISCLAIMER: Measurements mainly done to examine detector performance (not to demonstrate technique) • Measured a few archaeological objects, but no imaging • Software for composition analysis and image reconstruction not ready yet. • Not enough timing resolution yet.

  15. Measurements • Basic properties • Useful energy region: up to ~1 keV • Count rate (per pixel): ~200 kHz (5% dead time)

  16. Measurements • “Big” gold foil with 2.5mm hole. • No dip for pixel with hole  low cross-talk • As MC predicted plastic fibres no problem

  17. Measurements • Bronze sheet (90.5% Cu , 8.49% Sn, 0.088% Ag) • Good agreement • Missing peaks, mainly Iodine (upstream in beam)

  18. Measurements • Agreement less good. • Still good for imaging

  19. Measurements • Piece of bronze vase from Villa Giulia • Very corroded  could not measure tin with diffraction.

  20. Measurements • No problem to see tin resonances.

  21. Measurements • Diffraction: lot of incoherent scattering • Neutron radiography: low penetration }  lot of H • ANCIENT CHARM black box • NRT :  much higher penetration of high energy neutrons hydrogen moderates neutrons  peaks broader

  22. 0.25 0.20 0.15 0.10 0.05 0.00 -0.05 Measurements • All peaks about same height  thick silver (~1 cm ) • Peak amplitudes << 1  background from moderated neutrons. • Peak shape correct  still able to identify elements • Black box contains silver object, probably also hydrogen !!

  23. Conclusion • Successfully built 16 pixel prototype transmission detector. • Detector performed very well: Low cross-talk, high rate capability, acceptable energy range. • Successful NRT tests. We are very happy with the detector.

  24. Future • 100 pixel detector integrated with goniometer • Imaging • Diffraction

  25. The end • THANK YOU ∙