Explore the physics of energy flow in buildings and learn the math behind heat loss and efficiency. Discover practical solutions for creating comfortable, eco-friendly homes that save energy and reduce costs.
E N D
Comfortable homes that save the worldSustainable Environmental Economic DevelopmentOctober 27, 2007 Don Otto dpoconstruction.com
What Works “Sure, it works in practice, but does it work in theory?” • The physics of how buildings live in the environment • Convection, Conduction and Radiation • Some math formulas you can’t live without • Design: planning spaces that meet your needs with the fewest square feet • Testing each home for performance--the whole heating system, too • Financing: finding an appraiser who values EE
The science & math of energy flow Heat crosses the building envelope in only 3 ways: conduction, convection, radiation • Conduction (insulation) roughly accounts for 1/3 - 1/2 • Convection (air flow) also accounts for 1/3 - 1/2 • Radiation (electromagnetic) accounts for the rest Heat flow, (in Btu/hr) through insulation depends on conductance (U), sq. ft. area (A) and temperature difference from inside to outside (∆T): • Btu/hr = U x A x ∆T Heat flow by air movement depends on air flow rate (CFM), temperature difference inside to outside (∆T), and correction factor (1.08): • Btu/hr = CFM x ∆T x 1.08
Some real-world examples The formula for heat flow through insulation, Btu/hr = U x A x ∆T For a 1-story,1,000 sq ft house, (a 32’ x 32’ house walls also = ~ 1,000 sq ft) an inside temperature of 70° and cold outside winter air temperature of 0°F, or year-round ground temperature of 50° Conductive heat loss Un-insulated basement floor(R-1, U=1.0) 1,000 x 1.0 x 20 = 20,000 Btu/hr (the temperature below grade is about 50°, so the difference is only 20°, not 50°) But what if we installed insulation under the floor to R-10? R-10 (U = 0.1): 1,000 x 0.1 x 20 = 2,000 Btu/hr
How much energy do we lose by air leakage? (Air flow Btu = CFM x ∆T x 1.08) For 5 air changes per hour (ACH) and 1,000 sq ft: 1,000sq ft x 8’ x 5 ach/60min = 667 CFM. 667 CFM x 70° x 1.08 =50,350 Btu/hr Current ventilation standards(ASHRAE 62.2, 2004) recommend 7.5 CFM per person plus 1 CFM per 100 sq ft. For a three-BR house, a couple with 2 kids, per 1000 sq ft: 40 CFM x 70 x 1.08 = 3,024 Btu/hr That’s saving 94% of the energy we waste to heat the winter sky If we installed an energy recovery ventilation system, we could even recover 60 to 80% of that. Minnesota already requires one in all new homes.
Sight lines and focal points • Diagonal views are the longest possible. Focal points, like light from windows, attract the eye, making the space feel larger than it is
Does doing all this make a difference? • A home in Solon costs $180 a year to heat • It keeps 36,000 lbs of CO2 out the air • It’s comfortable all the time • The benefits will last the life of the house
How many ways do homes lose energy? How much? Where? • Inadequate insulation • Air leakage • Poor windows • Inadequate ductwork How do you know what to fix?
Performance testing • Building envelope leakage w/ blower door & Infra-Red camera • Entire heating system performance • Furnace & A/C or heat pump • Ductwork, airflow delivery • As well as windows and insulation • (the whole test costs between $300 - $400)
Financing energy upgrades Banks need appraisers who place a value on energy efficient features in order to include them on a loan. I know of one such appraiser: JIM POTTER, Preferred Appraisal, 319-373-6746