1 / 18

The Pixel Hybrid Photon Detectors of the LHCb RICH

This presentation discusses the structure, working principle, and characteristics of the pixel hybrid photon detectors (HPDs) used in the LHCb RICH detectors. It also presents the first results from the commissioning runs, current issues, and future plans. The LHCb detector, with its single-arm structure and good particle identification capabilities, will investigate properties related to the b quark and CP violation in physics.

jeffrosa
Download Presentation

The Pixel Hybrid Photon Detectors of the LHCb RICH

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. The Pixel Hybrid Photon Detectors of the LHCb RICH Presented by Flavio Fontanelli (Universita’ diGenova and I.N.F.N.) on behalf of the LHCb RICH Collaboration 11th Topical Seminar on Innovative Particle and Radiation Detectors (IPRD08) 1 - 4 October 2008   Siena, Italy

  2. Outline • LHCb detector • RICH detectors structure • HPDs working principle and characteristics • First results from commissioning runs • Current issues and future plans

  3. 250 mrad 10 mrad p p LHCb Detector Tracking system Muon system Dipole magnet Calorimeters Vertex Locator RICH detectors LHCb will investigate the properties of the b quark and the CPV-related Physics. Detector has a single-arm structure with good particle identification capabilities provided by 2 RICH detectors.

  4. RICH1: Radiator C4F10 (85 cm) and Aerogel (5 cm) Momentum between 1 and 60 GeV/c Acceptance: 25 – 300 mrad Magnetic shield box VerticalX-section HPD plane: 7 columns, 14 tubes each

  5. RICH2: Radiator CF4 (180 cm) Momentum range: between 17 and 100 GeV/c Acceptance : 10 – 120 mrad Top view Side view For a general description of RICH detectors see D. Perego’s poster at this conference

  6. Characteristics of HPD focal planes • 484 HPDs (Hybrid Photon Detector) :196 for RICH1 and 288 for RICH2 • ~3.3 m2 total surface • Granularity: 2.5 x 2.5 mm2(almost 0.5 million pixels) • Active area coverage >65 % • Single-photon sensitivity between 200-600 nm • Magnetic fringe field <25 G • Read-out: • Compatible with LHC 40MHz bunch crossing frequency • 10% occupancy (worst case)

  7. On-detector Off-detector data fibres DAQ link TTC fibres power cables control system A RICH2 column HPDs are mounted on columns together with readout electronics, power distribution & active cooling

  8. HPD : The Hybrid Photon Detector e- e- e- LHCBPIX1 Peak eff. >30% @ 270nm -16.4 kV -19.7 kV -20 kV

  9. HPD characteristics • HPDs developed in close collaboration with industry (Photonis-DEP lead partner) • Quartz window with S20 photocathode • Cross focusing optics: • 20 kV operating voltage • Demagnification of ~5 • Point Spread Function 200 mm at the chip level • Encapsulated binary electronics readout chip • Two possible readout configuration: • 256x32 basic pixels (0.0625x0.5 mm2 each) • 32x32 pixels (0.5x0.5 mm2 each) OR-ing 8 basic pixels at the digital level (no increase of noise) 87 mm 120 mm

  10. The solid state electronics e- e- e- Silicon sensor made by Canberra Expected signal: 5000 e- @ 20kV (2000 e- worst case in case of charge sharing) Threshold: 970 e- Noise: 130 e-

  11. System tests in a test beam The very good noise performance of HPDs are shown in this image obtained during a test run using a 80 GeV/c charged particle beam at CERN SPS. C4F10 ~1m. radiator length. Pixel map of a C4F10 ring focused on 4 HPDs integrated over ~50k events Photon Yield

  12. B┴  B║ Sensitivity to magnetic fields Axial Transverse 30G 30G Coils HPD (shielded with m-metal) LED & collimator used to produce pattern of light on HPD

  13. Effects of magnetic field on pixel position can be quickly spotted using a commercial projector illuminating the focal plane with a fixed point pattern.After filtering and pattern recognition we may compute the center of mass of each spot of light and then calculate how much a point has been rotated by the stray field on the RICH2 focal plane (1 HPD shown) Pattern seen by one of the RICH2 HPDs

  14. The net rotation effect due to stray magnetic field can be clearly seen here where the rotation angle <Dq > is plotted against HPD number

  15. And when you have a beamer at your disposal you may use it to project on the focal plan whatever you want… Single photon accumulated image taken shining from a projector (the same used for the magnetic distortion) on the C-side of RICH2. The light level over the whole surface is ~100 photoelectrons per event.

  16. RICH1 Detector Time alignment • Fine time alignment of Level 0 trigger required, in order to maximize photon collection efficiency: • Use 100ps pulsed laser • Delay of readout varied in steps of 1ns with respect to laser pulse S L0 board HPD 0 Not yet optimized ! HPD 1 Data acquired while scanning the trigger delay

  17. And finally you get (preliminary) DATA ! (only one beam injected) Rich2 A-side C-side Rich1 Upper and lower box Run number 32490 50 events accumulated (only Rich1 time aligned) – Tracks not directed from interaction point.

  18. Conclusions • LHCb RICH System is working and we started acquiring first data. • We have to complete alignment and calibrate it, but we already have seen photons from tracks and we are confident the RICH detectors will give beautiful physics results. • HPDs present many nice features and for sure they will be much used in future detectors.

More Related