1 / 1

Digital Imaging Based Flame Stability and Burner Condition Monitoring

Temp ( ° C). >1609. >1588. >1566. >1545. >1523. >1501. >1480. >1458. >1437. >1415. Filter.  1.  2. Introduction.

hung
Download Presentation

Digital Imaging Based Flame Stability and Burner Condition Monitoring

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Temp (°C) >1609 >1588 >1566 >1545 >1523 >1501 >1480 >1458 >1437 >1415 Filter 1 2 Introduction Co-firing of biomass with coal at existing coal-fired power plant has been widely adopted as one of the main technologies for reducing CO2 emissions. The variability in fuel properties and co-firing conditions can cause a range of combustion problems including flame stability, low thermal efficiency, high levels pollutant emissions and furnace fouling and corrosion. Advanced flame monitoring and characterisation technologies are therefore required for an in-depth understanding of the impact of biomass on combustion stability and subsequent optimization of the co-firing processes. As part of an EPSRC funded project - Optimisation of biomass/coal co-firing processes through integrated monitoring and computational modelling, research is being conducted to develop an advanced system for flame stability and burner condition monitoring in coal-biomass co-firing power plant. Collaborators: University of Leeds, University of Nottingham, Zhejiang University, Tianjin University and Xi’an Jiaotong University E.ON, RWE npower, Alstom Power and China Datang Corporation Contact: School of Engineering and Digital Arts, University of Kent, Canterbury, Kent CT2 7NT, UK Tel: +44 (0)1227 827315, Website: http://www.eda.kent.ac.uk/ Beam splitter Imaging sensor Objective Ocular 2 1.5 Power 1 Prism 0.5 Digital Imaging Based Flame Stability and Burner Condition Monitoring 0 20 40 60 80 100 120 140 160 180 Frequency (Hz) Image at 1 T=f(1, 2, G1, G2) Duo Sun, Gang Lu and Yong Yan Instrumentation, Control and Embedded Systems Research Group School of Engineering and Digital Arts, University of Kent Image at 2 Flame Temperature distribution Measurement of flame oscillation frequency • Flame signals are captured by UV, visible and IR photo detectors. • Embedded techniques are employed for on-line flame signal processing. Photo diodes Embedded signal processing board Cooling air in Mini motherboard Oscillation frequency detection board Objective lens Fuel, air Emissions FFT dsPIC Technical strategy Data output CPU Photo detector Oscillation frequency Optical probe & beam splitters Beam splitter CCD camera Endoscope Jacket • Temperature • Ignition • Luminosity CCD camera Example of a flame signal and its power spectrum Flame Measurement of flame temperature Flame stability assessment Recommendation to combustion operator • Two-colour method - Temperature is determined from flame radiation intensities at two wavelengths based on the Planck’s radiation law. Digital imaging and optoelectronics based technique for flame stability and burner condition monitoring System design Sensing arrangement for two-colour imaging • A miniaturised and integrated flame detection and imaging system. • • System can be installed at the burner through the sight-tube to • - avoid the modification of the furnace • - visualise the flame root region • - avoid possible interference from other burners • • Photo detectors for oscillation frequency measurement • • Miniature RGB CCD/CMOS camera for temperature measurement • • Real-time embedded image and signal processing Example of flame images and temperature distribution Concluding remarks • A system incorporating digital imaging and optoelectronic devices is being developed for flame stability and burner condition monitoring in coal-biomass co-firing power plant. • An embedded sensing and signal processing board has been constructed for the measurement of the flame oscillation frequency. • Initial tests have shown the relative error of the oscillation frequency measurement is not greater than 2%. • Future work will focus on the construction of the embedded subsystem for flame temperature measurement. 5 Amplitude 0 -5 0 0.5 1 1.5 2 2.5 Time (Sec) System design

More Related