html5-img
1 / 16

Future LP works

Future LP works. 2009/09/02 Manabu Togawa. Future LP work. RUN9 analysis (200 & 500 GeV ) Offline analysis & scaler analysis For future run Operation ZDC/SMD operation Upgrade of scaler mode Independent operation w/o PHENIX DAQ SMD scaler : Add Charge veto info.

hubert
Download Presentation

Future LP works

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Future LP works 2009/09/02 Manabu Togawa

  2. Future LP work • RUN9 analysis (200 & 500 GeV) • Offline analysis & scaler analysis • For future run • Operation • ZDC/SMD operation • Upgrade of scaler mode • Independent operation w/o PHENIX DAQ • SMD scaler : Add • Charge veto info. • ZDC energy info. • BBC hit info. • Make BBC scaler ?

  3. RUN9 analysis • We could use scaler data and offline analysis data which are produced by production. • Outputs are LR and UD asymmetries. Many thanks for Ruizhe to implement LP analyzer on production. • Details aredescribed in https://www.phenix.bnl.gov/WWW/p/draft/togawa/run9/localpol_run9_operation.pdf (pptx)

  4. Future : upgrade for SMD scaler • Independent operation • Currently ZDC (any?) LL1 needs BB GTM start; SMD scaler needs to BB GTM start. • It could be independent (GL1 GTM always running) • Add charge veto and/or ZDC energy information. • Need to consider small AN at beginning of fill. • While very stable at √ s = 200 GeV data. Fill#10325 Fill#10364

  5. Possible thought of small AN Need to monitor • Beam orbits • Colliding with finite crossing angle • Double collision • Check rate dependent (using BBC) • Background • Check rate dependent (using BG counters) Need to reduce Charge ADC, TDC Add : Could reduce BG Detector (ZDC,SMD) FEM DAQ BBC Trigger SMD: Make hit map according to the energy deposit above 20 MIP ZDCinfo. LL1 FPGA CV via fiber SMDinfo.

  6. Correlation with BG counters Inserted “blue V0” collimator Inserted any collimator ? Fill#10300 Unknown increase Unknown increase Need to reduce

  7. Fill#10450 (3/28 21:40 – 3/29 5:50) Yellow LR asymmetry Need to monitor Residual transverse components are significantly changed during this fill. CNI measurements were : 3/28 20:53 37.4±3.0 % 3/29 00:01 37.6±1.9 % 3/29 03:00 36.4±3.0 % Change at here significantly 10×10-4  12×10-4 Yellow UD asymmetry Waldo’s comment : Automatic orbit correction was not working in fill 10450. • The horiz orb showed a two clear states, but vert drifted. Change at here significantly -8×10-4  -4×10-4

  8. Will make BBC scaler ? • Luminosity  62 : 200 : 500 = same rate (roughly) • Cross section at BBC  62 : 200 : 500 = 14 : 24 : 30 (mb) • 62& 200 : Analysis note 688 500 : Amaresh’s presentation at W meeting (2009/06/12) • ZDCN|S ratio relative to BBC  62 : 200 : 500 = 24 : 36 : 67 • Total count rate for ZDCN|S  62 : 200 : 500 = 1 : 8 : 48 • Total AN/∆AN 62 : 200 : 500 = 1 : 9 : 42 Typical rate for ZDCN|S relative to BBC AN 62 : 200 : 500 ~ 2 : 6 : 12 (%)

  9. Estimation for scaler • Total AN/∆AN 62 : 200 : 500 = 1 : 9 : 42 • 62 GeV 1 s / point (5 mins)  3 s / 45 mins. • In addition, BG from charged particles are very high. • From pythia simulation, only 14% is neutron while ~25-33% for 200 and 500 GeV (with 5 GeV threshold). * Need to consider polarization, rate. 500 GeV : ~50 s / point (5 mins.) 200 GeV : ~10 s / point (5 mins.)

  10. Charged particles AN at PHENIX BBC in √ s = 200 GeV • Analysis done by Kazuya : https://www.phenix.bnl.gov/WWW/p/draft/aoki/meetings/run6/aoki-bbcLP-20060612.ppt • It will achieved 5 s measurement / hour  will be cross check BLUE FORWARD Fit func: p0 x cos( x – p1) YELLOW FORWARD Divided by pol. (pol ~50%) 1-LR 2-LR 3-LR 4-LR

  11. Possibilities • Use BB FEM out • BB FEM has TDC1 out put in front • Some of them now are used for BBC-MPC coin. Scaler. • Just put all out to scaler • Via logic unit?? • Same as SMD scaler • Hit information is sent via fiber to LL1. • Scaler will make on BBC LL1 board same as SMD board • Current BB LL1 is not re-programable. • New BB board for multi. collision logic has possibility ?? • No decision to make new one so far…

  12. Thank you so much! • Have a good LP !!!

  13. backup

  14. BBC PMTs Right Left

  15. BBC PMTs 3 4 2-L 1-R 1-L Exclusive asym (1-L) && !(1-R) VS !(1-L) && (1-R) 2-R

  16. Used fills(runs)