1 / 5

Technical Meeting , Sept 3, 2014 Paris, France

EMODnet Chemistry. Meeting on ODV QC and DIVA Products Paris Sept 3 rd 2014. SMHI – Baltic Sea. Technical Meeting , Sept 3, 2014 Paris, France. EMODnet Chemistry. SYNTHESIS OF ODV USE FOR REGIONAL QC Data set aggregation.

hedda-mccoy
Download Presentation

Technical Meeting , Sept 3, 2014 Paris, France

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. EMODnet Chemistry Meeting on ODV QC and DIVA Products Paris Sept 3rd 2014 SMHI – Baltic Sea Technical Meeting, Sept 3, 2014 Paris, France

  2. EMODnet Chemistry SYNTHESIS OF ODV USE FOR REGIONAL QC Data set aggregation. We want to implement the “SDN Aggregated ODV Collection” method. However all P01 codes are not yet mapped to P35. A definition of common methodologies for QC is much desired. We would like it to include common use of ODV built in methods for QC as well as guidelines for of how to implement the “QC-parameter_list” provided by Matteo. Also the following questions should be answered: Which flag are we using for which quality control, for example QF3 contra QF4 in “QC-parameter_list”? Exactly what information is to be included in the QC report/Annex (flag from/to, reason for flagging etc.)? Technical Meeting, Sept 3, 2014 Paris, France

  3. EMODnet Chemistry INTERACTION WITH DATA PROVIDERS Latvia One profile with spike in pH. Mail conversation with LHI. Fault due to mistyping. Profile corrected. Denmark22 profiles with position (0,0) and 4 with bad values. Mail conversation with DMU, which is investigating it. FinlandTwo profiles with bad values. Mail conversation with FMI, which is investigating it. Russia9 profiles with bad values. Mail conversation with RIHMI-WDC, which will update the files. If values matches the original documentations no changes will be made. GermanySeveral bad profiles. Mail conversation with BSH, which explained that the reason is that two profiles are taken at slightly different times had been merged together during export. This should be fixed by now. Two bad profiles (salinity) from Pangaea. Mail conversation with BSH and Pangaea. The files are archived by Pangaea, which asked US to inform the PI. E-mail was sent to the PI expressing our wish to update the files. He is looking into it. PolandFive profiles with bad values. Mail sent to IMWN MB. No response on progress yet. Estonia 1717 profiles with missing depth variable were excluded from the ODV collection and never checked. Mail conversation with MSI about issues regarding mismatching header and semantic header have been sorted out and hopefully the files will be correct in the next harvest. Furthermore some profiles did not have any depth profile. Only min and max depth was included in the ODV-files. This should also be fixed by now. Technical Meeting, Sept 3, 2014 Paris, France

  4. EMODnet Chemistry DIVA PRODUCTS We would like a general protocol with the basic options and setting and a guide with tips and remarks for regional specific setting. • In the DIVA var_list: Aggregated_pH have been analyzed as Aggregated_Phosphate. Hence, the parameter names in the var_listmust be unique to avoid confusion during data extraction. • The results must be masked when error fields are too high. How big errors should be accepted? • Must the limits be parameter specific? • Can someone explain relative error and actual errors? • Should we have different error expectations for different parameters? How handle this within the project? Technical Meeting, Sept 3, 2014 Paris, France

  5. EMODnet Chemistry DIVA set-up • Year list: 1990 – 2012 • Month list: January-February, July-August • Contour depth: 0, 20, 50, 100 meters • Qflist: 1,0,(7) • Ispec (error output) : 101, (clever poor man’s error) • Ireg(background field): 1 • Driver set-up? Technical Meeting, Sept 3, 2014 Paris, France

More Related