1 / 7

PFL20M Launch

PFL20M Launch. New Design. Substantial design changes reflect new direction. New filter design, new MTDRr, IP54 Multiple pre-location techniques Combine with MPP for powerful pinpoint accuracy. Mains or battery power option High energy with burn capability. Time Tested Features.

giza
Download Presentation

PFL20M Launch

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. PFL20M Launch

  2. New Design • Substantial design changes reflect new direction. • New filter design, new MTDRr, IP54 • Multiple pre-location techniques Combine with MPP for powerful pinpoint accuracy. • Mains or battery power option • High energy with burn capability

  3. Time Tested Features • Manual mode select switch, • Arc reflection • Impulse • Proof/Burn • Analog, continuously variable, voltage control. • Ultra reliable analog meters, default passive mode for safety. • Zero Start interlock, for safety

  4. Time Tested Features • Safety beacon interlock • Adjustable impulse interval • Rugged reliable field-tested design • Large wheels for easy maneuverability • Proof Voltage up to 20kV • Burn current for fault conditioning

  5. New Features • New MTDR retrofitted into specially redesigned cover • TDR • ARC • Impulse Current • Large, bright screen, suitable for direct viewing in direct sunlight. • Save & Recall traces internally or via USB • QWERTY keyboard

  6. New Features • New Inductive Arc Reflection Filter • “Lossless” device • Allows more surge current at the fault. • Stabilizes arc current at the fault, longer sustaining, better pulse echo reflector • Internal Inverter • Use mains power, vehicle battery or external battery • Non-louvered panels • IP 54, better suited for use in humid / damp conditions

  7. PFL20M-1500 Summary • Single range surge to 16 kV, 1536 Joules • Onboard Proof test, to 20kV • Burn (conditioning current) to 60mA • Linear Power Supply technology • 2-10 second “thump rate” • On-Board 12Vdc Inverter- new • Integral Inductive Arc reflection filter- new • Integrated MTDR1- new • “Louver-less” panels (IP54)- new Modes • TDR • ARC • ICE Modes • Surge • Burn • Proof