FEL Study Plans. Z. Huang LCLS Lehman Review May 14, 2009. Questions to be addressed here. What is the plan for detailed study and understanding of FEL performance and its sensitivity to the beam brightness, matching, (energy and phase errors), LSC, CSR, etc.?. What has been done?.

gelb
Download Presentation

FEL Study Plans

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. FEL Study Plans Z. Huang LCLS Lehman Review May 14, 2009

  2. Questions to be addressed here • What is the plan for detailed study and understanding of FEL performance and its sensitivity to the beam brightness, matching, (energy and phase errors), LSC, CSR, etc.?

  3. What has been done? • FEL gain length in nom. conditions (3 kA, 0.25 nC, 0.4 µm) • FEL-induced electron energy loss (4-8 MeV, or >1012) • Effects of Laser heating • Post-saturation taper • FEL bandwidth & central wavelength using Ni K-edge • Different compression configurations • Transverse coherence test (diffraction on finder-wires) • 20 pC run (fs pulses?) • Drive Laser spatial shaping study

  4. What is planned • Gain length dependence on Ipk (CSR?) & energy spread (LSC?) to understand our slice parameters • Gain length dependence on projected emittance, b-matching, different average beta in undulator • Emittance spoiling studies (using UV laser, OTR) • FEL wavelength tuning (1.5 nm – 1.5 Å) • Look for nonlinear third harmonic (in FEE?) • BC2 over-compression for chirped SASE • More extensive 20 pC studies • Other charge configurations (1 nC, 100 pC?)

  5. Gain length and saturation level 4.6 MeV At nominal machine conditions (250 pC, 3 kA under-compression, LH at 7 mJ, 13.6 GeV, 1.5 Å) gex,y = 0.4 mm (slice) Ipk = 3.0 kA sE/E = 0.01% (slice) DK/K = 0.16% FEL Gain Length = (3.3 ± 0.3) m Saturation energy ~ 1 mJ Most studies are done with these nominal parameters, will explore more beam parameter space

  6. Laser Heater Studies Laser optimal Laser heater OFF • Heater has shown its effectiveness • More studies to determine optimal heating and slice energy spread 12 undulators inserted here heater on heater off

  7. Dependence on peak current Laser heater =76 uJ Laser heater =11 uJ 12 undulators inserted (FEL not saturated here)

  8. FEL bandwidth Used Ni K-edge (w/ 12 undulators), Ni replaced by B4C May use YAG K-edge with saturated FEL at 11.3 GeV + enough attenuation Error function fit yields s=0.1% (FEL BW)

  9. Post-saturation Taper > 8 MeV E-loss (2 mJ) More taper studies with 8 more undulators to be installed

  10. Preliminary 20 pC results • Lased at 20 pC and saturated with 60 mJ energy • Do not know bunch length (must be short to support lasing) • More extensive 20 pC studies • Try to determine how short is the pulse? Photodiode signal after BC2 suggests bunch length < 1 mm (Ding et al., SLAC-PUB-13525) 20 pC FEL results

  11. Drive Laser shaping study ‘Bagel’ 20 mesh ‘Donut’ 50 mesh ‘Airy’ ‘Gaussian’ 2 x 50 mesh 180 mesh • Laser spatial shaping to determine sensitivity of slice emittance and FEL gain on drive laser transverse uniformity (effects of transverse space charge) • Slice emittance and FEL not very sensitive to spatial shaping, worse case 20 MG with emittance ~ 2 mm

  12. Other studies FEL dependence on laser temporal uniformity (effects of LSC) FEL gain length at higher peak current, and in over-compression mode (effects of CSR) Look for third harmonic with fundamental strongly attenuated (presence of strong third harmonic is another indication of FEL saturation)