CMS Pre-Shower Status at NCU

CMS Pre-Shower Status at NCU. A.C. Chen, Y.H. Chang, Apollo Go, W.T. Lin + 3 full time R.A.s + 5 engineers from ERSO and Miracle Tech. Co. Status of Silicon Production Bonding Stage Plans. Summary of IV/CV tests. Date batch# depth of n+ majority I@V>V fd

gayle
Download Presentation

CMS Pre-Shower Status at NCU

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. CMS Pre-Shower Statusat NCU A.C. Chen, Y.H. Chang, Apollo Go, W.T. Lin + 3 full time R.A.s + 5 engineers from ERSO and Miracle Tech. Co. Status of Silicon Production Bonding Stage Plans

  2. Summary of IV/CV tests Date batch# depth of n+ majority I@V>Vfd 6/5 cms01 14 mm 50-150 nA/strip 6/5 cms02 50-150 nA/strip 6/15 cms03 5 mm 100-150 nA/strip 6/18 cms04 50-100 nA/strip 6/18 cms053 mm 250-350 nA/strip 6/15 cms06 300-400 nA/strip • More than one strip have high leakage current that sensor • can not be accepted. • 20 accepted sensors : 17 from 03 and 04, 3 from 01 and 02 • 23oC, Cstrip=38 - 42 pF, Vfd= 80 - 120 V

  3. Measurement of Wafers aluminum 10x10 mm2 window passivation • Thickness of wafer 325 mm • Al : 2 mm, oxide 1.5 mm • p+ 4.7 mm, n+ 5 mm Oxide p+ n+

  4. Depth (mm) 4.7

  5. Depth (mm) 5

  6. 2nd layer Thermal oxide 1 mm + PECVD field oxide 0.5 mm 3rd layer Aluminum 2 mm 4th and 5th PECVD Oxide and Nitride 0.5 and 0.7 mm

  7. Status of Silicon Production • 4 batches of silicon wafers were delivered. • Starting from batch 51, size of window was changed to 10x10mm2 instead of 300x400mm2

  8. IV measured at 25oC, 63% of humidity

  9. Bonding Stage • New micro-stage has been installed and tested.

  10. Plans • ERSO and Miracle engineers are trying to improve the yield. If the yield is higher then 30%, then ERSO will start mass production. • Plan to deliver all the 1,200 wafers in 6 months. We expect to start in early 2003. • Keep the bonding stage alive.