AC031S/32S safety monitor: New functionality

AC031S/32S safety monitor: New functionality. SAFETY AT WORK. Date: 5/18/2009. Feature #1: Control of safety output modules. Application: Shut off multiple motors on a single conveying zone

Download Presentation

AC031S/32S safety monitor: New functionality

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. AC031S/32S safety monitor: New functionality SAFETY AT WORK Date: 5/18/2009

  2. Feature #1: Control of safety output modules • Application: Shut off multiple motors on a single conveying zone • Advantage: Safety output module reduces wiring complexity; less wire to run back to main control panel.

  3. Feature #1: Control of safety output modules 1 2 3 4 5 6 7 AC031S/32S • Typical configuration layout shown above. • AC031S or 32S has an additional integrated node built into the safety monitor located at terminal AS-IS

  4. Feature #1: Control of safety output modules AC031S/32S • In order to control the safe output modules, the AS-IS terminals must be wired back to the AS-I + and - • AS-IS is treated like a safety node and will take an address on the current network. You might need to reconfigure the AS-i master when the AS-IS terminal has been addressed.

  5. Feature #1: Control of safety output modules Address selection for the AS-IS terminal *Make sure to check “Actuator” • The address for the AS-IS terminal is given in the ASIMON software v3.00 or greater (as shown above). • In this example, we will provide an address 29. Note: This address is NOT the monitor address! For feedback indication, a safety monitor address can be given as well. The monitor address and AS-IS address are two separate entities.

  6. Feature #1: Control of safety output modules AC030S safety output modules are control by the logic in the 2nd OSSD • Whether you use the AC031S or AC032S monitor, you must have logic in the 2nd OSSD (2nd safety zone) to control the safety output modules. The safety output modules will follow this logic. In our example, this is the logic for the AS-IS terminal; address 29.

  7. AC030S Feature #1: Control of safety output modules • The AC030S has a small dip switch on the front of the unit for programming the addresses on the unit. R= Run or P=Program • In run mode, the module will act as a extended addressing module with 4 standard non safe inputs (This is the normal operation mode) • In program mode, you will teach the address of the safety monitor (AS-IS) you want the module to listen to. *Note: This address will not take a physical address on the AS-I system • Switch back into run mode when complete

  8. 29 Feature #1: Control of safety output modules AC031S/32S 8A/ Listen to 29 9A/ Listen to 29 • In the above example, 2- AC030S have been added to the system to safely shut off motors. • In normal operation, the 2- AC030S modules above will mimic the 2nd safety zone of the safety monitor. Both units are listening and will change state based on the AS-IS terminal addressed at 29.

  9. Feature #2: Communication to a second SAW network • Application: Communicate status to a second SAW network for global shutdown of both systems • Advantage: In the past, a separate safety module was required on the second network to perform the same task. This has been eliminated with the new safety monitors.

  10. Feature #2: Communication to a second SAW network • Typical configuration above with two separate safety networks • AC031S or 32S has an additional integrated node built into the safety monitor located at terminal AS-IS

  11. Feature #2: Communication to a second SAW network • The AS-IS terminals are wired to the AS-I + and – of the second safety network • In the example, node 29 (AS-IS) will now appear in the second safety network.

  12. Feature #2: Communication to a second SAW network Address selection for the AS-IS terminal *Make sure to check “Input Slave” • The AS-IS terminals are wired to the AS-I + and – of the second safety network • In the example, node 29 (AS-IS) will now appear in the second network.

  13. Feature #2: Communication to a second SAW network • The address of the AS-IS terminal will act like a standard safety slave on the second safety network.