1 / 25

The Very Forward Region of the ILC Detectors

The Very Forward Region of the ILC Detectors. Ch. Grah FCAL Collaboration TILC 2008, Sendai 04/03/2008. Contents. Forward Calorimetry Overview LumiCal, BeamCal Beamdiagnostics using BeamCal and GamCal BeamCal Electronics R&D Summary. Design of the Forward Region. GamCal ~185m.

gaiter
Download Presentation

The Very Forward Region of the ILC Detectors

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. The Very Forward Region of the ILC Detectors Ch. Grah FCAL Collaboration TILC 2008, Sendai 04/03/2008

  2. Contents • Forward Calorimetry Overview • LumiCal, BeamCal • Beamdiagnostics using BeamCal and GamCal • BeamCal Electronics R&D • Summary The Very Forward Region

  3. Design of the Forward Region GamCal ~185m BeamCal LumiCal ILC RDR The Very Forward Region

  4. Tasks of the Forward Region IP ECal and Very Forward Tracker acceptance region. • Precise measurement of the integrated luminosity (ΔL/L ~ 10-4) • Provide 2-photon veto LumiCal • Provide 2-photon veto • Serve the beamdiagnostics • using beamstrahlung pairs • Pair Monitor (see talk by Itoh) ~150mrad BeamCal ~40mrad GamCal 5mrad • Serve the beamdiagnostics • using beamstrahlung photons Beamstrahlung Challenges: High precision, high occupancy, high radiation dose, fast read-out! The Very Forward Region

  5. The LumiCal Precise Measurement of the ILC‘s luminosity The Very Forward Region

  6. Precise Measurement of the Luminosity Pair Monitor • Required precision is:ΔL/L ~ 10-4 (GigaZ 109/year)ΔL/L < 10-3 (e+e-W+W- 106/year)ΔL/L < 10-3 (e+e-q+q- 106/year) • Bhabha scattering ee->ee(γ) is the gauge process: • Count Bhabha event in a well known acceptance region => L = N/σ • High statistics at low angles => NBhabha ~ 1/θ3 • Well known electromagnetic process (LEP: 10-3): the current limit on the theoretical cross section error is at ~5 10-4. BeamCal LumiCal The Very Forward Region

  7. LumiCal: Design Parameters • 1. Placement: • 2270 mm from the IP. • Inner Radius - 80 mm • Outer Radius - 190 mm • 2. Segmentation: • 48 sectors & 64 cylinders: • Azimuthal Cell Size - 131 mrad • Radial Cell Size - 0.8 mrad • 3. Layers: • Number of layers - 30 • Tungsten Thickness - 3.5 mm • Silicon Thickness - 0.3 mm • Elec. Space - 0.1 mm • Support Thickness - 0.6 mm The Very Forward Region

  8. LumiCal Aperture anti-DID DID • The inner radius of 80mm (z = 2270mm) keeps a security margin of about 1 cm for the beamstrahlung pairs in the anti-DID case. The Very Forward Region

  9. The BeamCal and Beamdiagnostics The Very Forward Region

  10. BeamCal Design Pair Monitor • Compact em calorimeter with sandwich structure: • 30 layers of 1 X0 • 3.5mm W and 0.3mm sensor • Angular coverage from ~5mrad to ~45 mrad • Moliére radius RM ≈ 1cm • Segmentation between 0.5 and 0.8 x RM BeamCal LumiCal W absorber layers ~15cm Radiation hard sensors with thin readout planes Space for readout electronics BeamCal + graphite in front of BeamCal to reduce backscattering ~12cm The Very Forward Region

  11. BeamCal Challenges • BeamCal will extendthe sensitive regionto lowest polar angles. • Challenge:Detect single high energetic particleon top of a background of 104 low energetic e+e- pairs. • BeamCal serves is part of the beam diagnostics system, providing a ‘beamstrahlung pair’ information to the feedback system. Physics signal: e.g. SUSY smuon production Background signal: 2-photon event, may fake the upper signal if the electron is not detected. The Very Forward Region

  12. Fast Beamdiagnostics • Obtain as much information about the collision as possible. • BeamCal measures the energy of pairs originating from beamstrahlung. • GamCal will measure the energy of the beamstrahlung photons. • Generate a fast feedback signal in realtime. Simulation of the Fast Feedback System of the ILC. Define a signal proportional to the luminosity which can be fed to the feedback system. position and angle scan • Standard procedure (using BPMs) • Include pair signal (N) as additional input to the system • Increase of luminosity of 10 - 15% G.White QMUL/SLAC RHUL & Snowmass presentation The Very Forward Region

  13. Requirements on BeamCal • Use the pair background signal to improve the accelerator parameters. • The spatial distribution of the energy deposition from beamstrahlung pairs contains a lot of information about the collision. • Use a fast algorithm to extract beam parameters like:beam sizes (σx, σy and σz) emittances (εx and εy) offsets (Δx and Δy) waist shifts (wx and wy) angles and rotation (αh, αv and φ) Particles per bunch (Nb) The Very Forward Region

  14. Concepts of the Beamstrahlung Pair Analysis Simulate Collision with Guineapig 1.) nominal parameter set 2.) with variation of a specific beam parameter (e.g. σx, σy, σz, Δσx, Δσy, Δσz) G.White: 2nd order dependencies Produce photon/pair output ASCII File A.Sapronov: BeCaS1.0 Run full GEANT4 simulation BeCaS and calculate energy deposition per cell (geometry and magnetic field dependent) LC-DET-2005-003 Diagnostics of Colliding Bunches from Pair Production and Beam Strahlung at the IP Achim Stahl Calculate Observables and write summary file Do the parameter reconstruction using 1.) linear approximation (Moore Penrose Inversion Method) 2.) using fits to describe non linear dependencies The Very Forward Region

  15. Moore Penrose Method Taylor Matrix ΔBeamPar Observables Observables = + * nom • observables: • total energy • first radial moment • inv. radial moment • l/r, u/d, diag asymmetries • E(ring ≥ 4) / Etot • E / N • phi moment • inv. phi moment • f/b asymmetries • total photon energy (extern) • beam parameters (diff and av) • bunch sizes • emittances • beam offsets • waist shifts • bunch rotations • profile rotations • number of particles The Very Forward Region

  16. Beam Parameter Reconstruction Single parameter reconstruction using whole calorimeter data Photon energy can be provided by GamCal. A.Sapronov The Very Forward Region

  17. E_tot: Total energy R_mom: Radial moment Irmom: "Inverted" rmom Z_mom: Z moment Izmom: "Inverted" zmom E_gam: Gamma energy UDimb: Up-Down imbalance RLimb: Right-Left imbalance DgImb: Diagonal imbalance NovrE: N/E Phi_M: Phi moment IphiM: "Inverted" phimom A_dir: forward-backward direct asymmetry A_xsd: forward-backward crossed asymmetry Bunch width x (nm), Ave/Diff Bunch width y (nm), Ave/Diff Bunch length z (µm), Ave/Diff Emittance in x (10-6 m rad), Ave/Diff Emittance in y (10-9 m rad), Ave/Diff Beam offset in x (nm) Beam offset in y (nm) Horizontal waist shift-x (µm) Vertical waist shift-y (µm) # of part. per bunch (1010), Ave./Diff. No angle reconstruction (can be optimized by scans) Some beam parameter constrained by external measurements. Observables/Beam Parameters Combination of both BeamCals. The Very Forward Region

  18. Possible schemes for clustering (readout electronics) No clear indication of a preferred layer combination. …and Data Reduction angular clusters (prefered for reconstruction) rel. precision of the vertical beam offset reco pattern chose 2 layers in the shower maximum radial clusters (prefered for electronics) layer/depth The Very Forward Region

  19. Multiparameter Reconstruction • Full Multiparameter Reconstruction • (except angles) using: • 32 channel cluster (angular) • layers 8/9 (summed) • constraint on emittance of 10% • digitization of 8 Bit The Very Forward Region

  20. Correlations • Correlations between beam parameters are there. Some are very large. • We might reduce correlations by using other sources of information. • We might also just be able to give a resolution on a combination of highly correlated parameters. The Very Forward Region

  21. FCAL R&D Electronics The Very Forward Region

  22. BeamCal Electronics • 32 channels per chip • High occupancy, all data is read out at 10 bits for science purposes; • Low latency output, sum of all channels is read out after each bx at 8 bits for beam diagnosis (fast feedback) • Prototype in 0.18-m TSMC CMOS technology • April 2007: High level design complete • July 2007-July2008: Layout design • August 2008: Verification complete • October 2008: Prototype ready • January 2009: Prototype tests complete A.Abusleme The Very Forward Region

  23. BeamCal Electronics Operation A.Abusleme • Dual-gain front-end electronics: charge amplifier, pulse shaper and T/H circuit • Successive approximation ADC, one per channel • Digital memory, 2820 (10 bits + parity) words per channel • Analog addition of 32 channel outputs for fast feedback; low-latency ADC The Very Forward Region

  24. Timing and Architecture data formatter feedback proc. A.Abusleme ~ 50 signals per layer of BeamCal Pair Monitor, GamCal etc Readout in real time and with low latency (~1 μs) Readout between bunch trains Need one more level in the readout architecture for the interface to FONT and to the detector DAQ. FONT DAQ The Very Forward Region

  25. Summary • The geometry of LumiCal (and BeamCal) has been adjusted for the 14mrad (AntiDID) option. • Beam Parameter Reconstruction using BeamCal has been tuned for a multi parameter reconstruction. • Results are very interesting but some beam parameters are highly correlated. • BeamCal electronics are currently being designed, implementing a fast feedback link (32 channel clusters/8 bit). The Very Forward Region