An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. PSU Physical Security Project Supervised by: Ms. Faten Alhanouf Alnasser ID# 207410054 DeemaAlhudaithy ID# 102400543 Maha Al shamekh ID#2 07410220 Quality Team

  2. § Outline: • Quality Standards Definition • Fire Extinguishers Quality Standards • Fire Alarms Quality Standards • Server Rooms Quality Standards • File Cabinets Quality Standards • Paper Shredders Quality Standards • Door/ Locks Quality Standards • References

  3. § Quality Standards Definition • According to ISO, standard is a published document. • It is a set of rules to be used consistently as good principles, practices or guidelines.

  4. § Server Rooms Quality Standards • Room specifications: • Room walls, ceiling, and doors should be sound isolated from other occupied areas. • Doors should be 42" to 48" wide, and 8' tall. • Room should not have windows (security reasons) • a minimum 9' ceiling. 5

  5. § Server Rooms Quality Standards • Cooling And Air conditioning • Racks should be arranged in a hot isle/cold isle • cooling and humidity control should be via an independent AC system (i.e., not connected to main building system), with a return air design temperature of 72°F (±2°F) • and humidity 45% (±5%), respectively. • There should be sufficient clearance (minimum 4') between the A/C unit and computer racks in order to avoid potential damage from water leaks, as well as to allow for maintenance access. 6

  6. § Server Rooms Quality Standards • Emergency and fire • Emergency/backup power dependent from departments • Room should be fire rated if cabling and cooling systems are combined in the same space above the ceiling or below the floor. 7

  7. § File Cabinets Quality Standards • Inset toe kicks are constructed of 1⁄2” thick unfinished engineered wood • Tops, bottoms, and floors are 1⁄2” thick • Cabinets must be resistant to fire. • Locks must be resistant to drills. 8

  8. § File Cabinets Quality Standards 9

  9. § Door/ Locks Quality Standards • Cardreaderdoorlock • Electronic system to manage the lock. • Voice alert in the case of unauthorized access . • protection from unauthorized access . (five times after a failed registration system stops for a few minutes). • Uninterrupted Power Supply (UPS) backup • Size of body lock: 130mmL x 106mmW x 40mmH Net weight of body lock: 1.06Kg 10

  10. § Paper Shredders Quality Standards • Cross-cut shredder: • provide more security by cutting paper vertically and horizontally into confetti-like pieces. • Safety standards: • Safety sensor : automatically shuts off when hands are too close to the paper entry. • Safety lock: puts the shredder into a safe, inactive mood. • Safety flap: covers cutters when the shredder head is removed • Safety interlock switch: ensures the shredder will not activate when the shredder head is removed • Common product specification: • Length: 14.00 in • Width: 16.00 in • Height: 25.00 in • Weight: 66.00 lbs 11

  11. § Fire Extinguishers Quality Standards • Listed under the National Institute and Occupational Safety and Health is the following standard for Portable fire extinguishers (1910.157): • The requirements of this section apply to the placement, use, maintenance, and testing of portable fire extinguishers • Extinguishers readily accessible • The employer shall assure that portable fire extinguishers are maintained in a fully charged and operable condition and kept in their designated places at all times except during use. • There must be a sign showing the place and the type of Extinguishers

  12. § Fire Alarm Quality Standards • Common guidelines for fire alarm systems include: • The detector base shall be suitable for surface mounting on a ceiling and shall fit on a 65 mm standard C-type electrical outlet box with fixing holes at 50 mm centers. Fixing lugs or holes in the base shall be substantial and shall withstand repeated insertion and removal of the head without damage. • The base shall be provided with wire terminals suitable for wire sizes up to 1,5 mm2.

  13. Any Questions? 14

  14. Thank you for listening! 15

  15. § References: • ISO Standards Definition | eHow.comhttp://www.ehow.com/facts_5762097_iso-standards-definition.html#ixzz1KBhJdQYP • http://www.ocio.usda.gov/directives/doc/DM3510-001.htm • http://www-act.ucsd.edu/blink/svr_rm_stds.pdf • http://www.squidoo.com/All-About-Quality-Assurance • http://www.fas.org/irp/offdocs/dcid1-21.pdf • http://www.woodmark-homedepot.com/pdfs/cabinetSpecs.pdf • http://www.inspiredelearning.com/Physical_Security/physical.security.standards.htm?link=id3 • http://www.atlantaaircargo.com/TD72_56.pdf • http://www.handles4doors.co.uk/help/helpMeasureDoor.aspx • http://prodesk.baldwinhardware.com/pro/tools/PDF/pricebooks/Arch/7-Archet_Lock%20Specs.pdf • http://www.handles4homes.com/default.asp?cid=18&sid=902098151 (picture of lock) 16