introducing gac s new line of intelligent generator set controllers n.
Download
Skip this Video
Loading SlideShow in 5 Seconds..
Introducing GAC’s New Line of Intelligent Generator Set Controllers PowerPoint Presentation
Download Presentation
Introducing GAC’s New Line of Intelligent Generator Set Controllers

Loading in 2 Seconds...

play fullscreen
1 / 23

Introducing GAC’s New Line of Intelligent Generator Set Controllers - PowerPoint PPT Presentation


  • 119 Views
  • Uploaded on

Introducing GAC’s New Line of Intelligent Generator Set Controllers. The InteliGen. Stand-By, Prime Mover (single and multiple set), and Parralel to Utility (single and multiple set) Applications Features: 128 x 64 LCD 9 / 9 Discrete Inputs and Outputs (Configurable) Expandable

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about 'Introducing GAC’s New Line of Intelligent Generator Set Controllers' - fineen


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
the inteligen
The InteliGen
  • Stand-By, Prime Mover (single and multiple set), and Parralel to
  • Utility (single and multiple set) Applications
  • Features:
  • 128 x 64 LCD
  • 9 / 9 Discrete Inputs and Outputs (Configurable) Expandable
  • to 21 / 21
  • 3 Analog Inputs (Fuel Level, Coolant Temp., Oil Press.)
  • Expandable to 7 and 1 Analog Output
  • Speed Measurement (Mag Pick-Up)
  • 3 Phase Generator / Utility Voltage Measurement
  • 3 Phase Generator Current Measurement
  • 1 CT Input for Utility Measurement or Earth Fault Protection
  • RS232 for Direct Communication
  • Meets NFPA110 (w/ Annunciator Module iGL-RA15)
  • Remote Communication (Analog, Internet, and GSM)
inteligen connections
InteliGen Connections

3 Phase Utility

Voltage

3 Phase Generator Voltage

9 Configurable

Discrete Inputs

and Current

Connection for

IOM / COM

Module

Connection

for Power

Modules

Mag. Pick-up

3 Analog Inputs

(Oil, Temp., Fuel.)

Direct PC

or Modem

Connection

Utility Current

2 Relay Outputs

(Starter, Fuel Solenoid)

7 Config. Outputs

12 or 24 V DC

inteligen s modules
InteliGen’s Modules
  • Power Control Modules: PCM and PCLSM (with Load
  • Sharing)
  • AVR control (needs 18 V AC power supply)
  • Communications
  • Expandable I / O
  • Modem Support (multiple set applications)
power control modules
Power Control Modules

Shielded Analog Load

Sharing Line(PCLSM only)

Governor Control Output

AVRi Output

Mounts Directly to Back of InteliGen

12 or 24 V DC

4 Discrete Inputs

4 Discrete Outputs

avri module
AVRi Module

Output Level Adjustment (turn pot)

18 V AC Power Supply

Output for AVR Control

Input from PCLSM

DIN Rail Mounting

communication module
Communication Module
  • Used for Multiple Set Applications
  • Communications Between Sets
  • Mount: Back of InteliGen
  • Up to 32 Sets
  • Use one Modem (w/iG-MU)
  • RS232 port for IOM
iom ptm module
IOM / PTM Module

9 Discrete Inputs w/ Active LED

4 Analog Inputs*

1 Analog Output

RS232 for Direct

PC Connection

RS232 Connection

to InteliGen

9 Discrete Outputs w/ Active LED

12 or 24 V DC w/

Power LED

DIN Rail Mounting

intelimains inteligen with special software
InteliMains: InteliGen With Special Software
  • Mains (= Utility) Circuit Breaker Control
    • Reverse Synchronization
    • Vector surge protection (locally required)
  • Power Management - Engine Usage Optimization
    • Number of running engines: Dependent on required load
    • Engine starting order: Dependent on running hours
  • Import/Export Control
parallel to utility other gen set s

iG-COM

iG-COM

G

G

iG-PCLSM

iG-PCLSM

Parallel To Utility & Other Gen Set’s

+ iG-COM + iG-PCLSM

InteliMains

+ iG-COM + iG-PCLSM

inteligen s user friendly operating software
InteliGen’s User Friendly Operating Software

Setpoints

Controller

  • Free
  • User Friendly
  • PC Format

History

Values

value screen
Value Screen

All Metered

Values in

Real Time.

Metering

Screen Selection

history
History
  • Every Action Logged
  • All Values Associated
  • w/ that Action
  • Up to 177 events
  • (FIFO)
controller
Controller
  • Same as Keypad
  • Essential Metering
  • Alarm List
setpoints
Setpoints
  • Change any Setpoint
  • Current Value
  • Range

Value

Screen Selection

Acceptable Range

for Parameter

customizable software
Customizable Software
  • Parameters
  • Nominal RPM 80  300
  • Multilingual Texts
    • Overspeed Überdrehzahl Sobrevelocidad
  • Units
    • °C F; kPa bar psi
  • Controller Operating Mode
    • SPM  SSB  SPtM  MINT  MEXT
  • Text
    • Water temp Coolant temp
controller screens

Water Temp 91°C

Oil Pressure 5.1bar

Fuel level 75%

Battery voltage 25.2V

Controller Screens
  • Analog Meters
  • Bar Graphs
  • Numeric Values
  • Controller Screens Allow for Similar
  • Interface as WinEdit Software

MAINS:

230 228 233V 50.0Hz

GENERATOR: 1517RPM

221 223 220V 50.6Hz

872 896 932A 0.98L

183 194 208kW 118kVAr

Running in Island

setpoint adjustment
Setpoint Adjustment
  • Adjustable via iG Keypad
  • Three Level Password Protection

PARAMETERS

MF-Start Delay 3s

Start Attempts 5

Mains OK-Delay 10s

Cooling time 30s

history screens
History Screens
  • History Events Can be Viewed From iG Screens
  • as well as WinEdit
  • Viewed on Multiple Screens

-15 FINISHED HOUR

07:00:00 16.10.

-16 GCB CLOSED-ISLAND

06:23:53 16.10.

-17 ENGINE START

06:23:49 16.10.

-18 MF-MCB OPENED

06:23:44 16.10.

85kW 1503RPM 0.81L

88C 6.1bar 24.9V 84%

50kW 1495RPM 0.72L

25C 5.3bar 24.7V 87%

0kW 0RPM -

22C 0.0bar 25.8V 87%

0kW ORPM -

22C 0.0bar 25.8V 87%

M 0 0 0V 0.0Hz

G233 227 229V 50.1Hz

M 0 0 0V 0.0Hz

G230 228 223V 49.8Hz

M 0 0 0V 0.0Hz

G 0 0 0V 0.0Hz

M190 195 201V 48.7Hz

G 0 0 0V 0.0Hz

121 125 124A 62kVAr

27 29 29kW

72 73 71A 48kVAr

17 18 16kW

0 0 0A

0 0 0kW

0 0 0A

0 0 0kW

protection handling
Protection Handling
  • Adjustable Delay Settings
  • Five Protective Actions
    • Warning
    • Slow stop
    • Shut-down
    • Unloading
    • History Record
  • Reset Function (Horn + Flashing Light)
protections
Protections
  • Generator / Utility Over / Under Voltage and Frequency
  • Voltage and Current Asymmetry
  • OverCurrent
  • OverLoad
  • Excitation Failure
  • Earth Fault
  • Oil Pressure (two level: warning, shutdown)
  • Coolant Temp. (three level: low temp warning,
  • high temp warning, and high temp shutdown)
  • Fuel Level (two level: warning, shutdown)
summary
Summary

The InteliGen Offers the Right Solution for the Application.

Never Pay for Unneeded Features.

GAC Leaves it up to You to Make the Intelligent Choice!!