Vibration of the Support Tube: Luminosity Lost and Found

Vibration of the Support Tube: Luminosity Lost and Found. Alan Fisher, Jim Turner, Franz-Josef Decker, Mike Sullivan, Clive Field 2007-04-12. 10 Hz on BPM Y FFTs. Decker has seen 10 Hz on BPMs since last summer, often at much higher levels than this picture taken today.

fay
Download Presentation

Vibration of the Support Tube: Luminosity Lost and Found

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Vibration of the Support Tube:Luminosity Lost and Found Alan Fisher, Jim Turner, Franz-Josef Decker, Mike Sullivan, Clive Field 2007-04-12

  2. 10 Hz on BPM Y FFTs Decker has seen 10 Hz on BPMs since last summer, often at much higher levels than this picture taken today.

  3. 9.75 and 19.5 Hz on Luminosity Peaks at 9.75 Hz and its second and third harmonics, plus sidebands at ±9.75 Hz around 60 Hz.What is moving? 0 Hz 100 Hz

  4. Vertical Geophone Tests: Backward Q5

  5. Backward Q4

  6. Backward Q4, Shaking the Raft

  7. Backward Q2

  8. Forward Q5

  9. Forward Q4

  10. Forward Support-Tube Bracket Finally: A strong peak at ~9.75 Hz

  11. Repeat Support-Tube Bracket 9.75 again, but a second peak just over 10 too.Second peak doesn’t appear in luminosity spectrum.

  12. Fast Luminosity Signal • Put Clive’s high-bandwidth luminosity signal (designed for fast dither) onto scope. • During Y dithers, this slows to ~10 Hz, larger amplitude. • These are clearly lumi dips when using DC coupling. • With 1-µm dithers, the lumi dips just recover to baseline at top of each 10-Hz period. • Y dither lowers lumi, vibration restores it. • Hash is ~20 Hz. • 2nd harmonic as vibration drops lumi on both sides of peak. 1 s/div Fast lumi signal is AC coupled 2 µm dithers in Y

  13. Correcting the Vibration • Support tube and beams appear to be vibrating vertically at one sharp frequency, close to 9.7 Hz. • Can we cancel noise by moving the beams? • Ideally, drive Q1 air-core trim corrector at same frequency and opposite phase. • Need a clean signal locked to vibration. • Adjust amplitude to null lumi component at this frequency. • Lock-in amplifier can measure and produce a drive signal. • Kepco BOP supply, same as used for fast dither. • Proof of principle yesterday: • Used Y fast dither set close to vibration frequency. • Beats in and out of phase with vibration, making lumi better and worse: 4% lumi gain found right away.

  14. Canceling Vibration with Y Fast Dither t=50: Fast dither starts, 9.75 Hz, 0.6 µm t=275: Change to 9.70 Hz, 1 µm

  15. Magnitude of lock-in signal is strong during luminosity dips.