Chlorerede ol sningsmidler nyheder fra konferencen i monterey
Download
1 / 12

- PowerPoint PPT Presentation


  • 67 Views
  • Uploaded on

Chlorerede oløsningsmidler , Nyheder fra konferencen i Monterey. Kirsten Rügge , COWI Hvad er nyt på området? Hvad er i udvikling? Hvor ser det ud til, at vi er på rette vej? Og hvor skal vi prøve andre teknologier? Hvilke spændende udfordringer kunne vi overveje at tage op i fremtiden?.

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about '' - ernie


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
Chlorerede ol sningsmidler nyheder fra konferencen i monterey
Chloreredeoløsningsmidler, Nyheder fra konferencen i Monterey

Kirsten Rügge, COWI

  • Hvad er nyt på området?

  • Hvad er i udvikling?

  • Hvor ser det ud til, at vi er på rette vej?

  • Og hvor skal vi prøve andre teknologier?

  • Hvilke spændende udfordringer kunne vi overveje at tage op i fremtiden?

Monterey 2010


Cowis deltagere
COWIs deltagere

Monterey 2010


Enhance vapor intrusion assessment and mitigation
Enhance Vapor Intrusion Assessment and Mitigation

Christopher C. Lutes (Christopher.Lutes@arcadis-us.com), Robert Uppencamp,and Carl Singer (ARCADIS U.S., Inc., NC, USA), Ronald Mosley and Dale Greenwell (U.S. EPA, Research Triangle Park, NC, USA)

  • Radon som tracer for chloreredeopløsningsmidler

  • Radon somværktøjtilfastlæggelseafkildeplacering

  • Radon somværktøjtiladskillelseafjordforureningogindendørskilder

Monterey 2010


Tracking vapor intrusion pathways an active tracer gas test
Tracking Vapor Intrusion Pathways – An Active Tracer Gas Test

Per Loll (pl@dmr.dk), Poul Larsen, and Claus Larsen (DMR A/S, Denmark)

  • Tracertesttilbestemmelseafspredningsveje for forureneing

  • Støttetilvalgafafværgemetode

  • Dokumentation for udførtafværge

  • Gas: 5% H2 og 95 %N2

  • Billigthåndholdtmåleinstrument

Monterey 2010


Vapor intrusion modeling influence of barometric pressure changes on soil gas concentrations
Vapor TestIntrusionModelingInfluence of BarometricPressureChangesonSoil Gas Concentrations

Annette P. Mortensen and Anders G. Christensen (AGC@NIRAS.DK)(NIRAS A/S, Allerød, Denmark), Lillian D. Abreu1 and Neal Durant (Geosyntec, Baltimore, USA), Lizzi Andersen (COWI A/S,Lyngby, Denmark), Mette Christophersen (Region of Southern Denmark, Vejle, Denmark)1Now at Arcadis, San Francisco, USA.

  • Store variationervedgentagnemålingerafporeluft under gulvogindendørsihuse (op til 4 størrelsesordner)

  • Ændringeribarometertryk giver < 5% variation iporeluft, lidtstørreindendørs

  • Variationerskyldessandsynligvismåleusikkerhed

Monterey 2010


A new quantitative passive sampler for vapor intrusion assessment the pdms membrane sampler
A New TestQuantitative Passive Sampler for VaporIntrusionAssessment:The PDMS Membrane Sampler

Hester Groenevelt (hgroenevelt@geosyntec.com) and Todd McAlary, (Geosyntec Consultants, Inc., Ontario, Canada), TadeuszGórecki and Suresh Seethapathy (University of Waterloo, Ontario, Canada), Heidi Hayes (Air Toxics, Ltd., Folsom, CA).

  • Indeklimakoncentrationermålestypisk med "1 to 6 liter Summa canisters" fyldt over få minutter (for porelufttil 24 timer, for indeklimamålinger)

  • Waterloo sampleren, lillerørtilpassivopsamling over dage/uger

  • Nem at håndtere

  • Billig at analysere

  • Genbrugesikke

Monterey 2010


Using multiple lines of evidence in a vapor intrusion evaluation
Using Multiple Lines of Evidence in a Vapor Intrusion Evaluation

AmyGoldberg Day (Amy.GoldbergDay@Arcadis-US.com), (ARCADIS, Emeryville, California, USA)

  • Johnson & Ettingervapor transport model (2009) anvendt til at modellere indeklimakoncentrationer i en forretning i et center

  • Målte koncentrationer langt højere end modelleret

  • Renseri i centret

  • Konklusion: Godt at kende omgivelserne !

Monterey 2010


Hvordan udf res indeklimam linger
Hvordan udføres indeklimamålinger Evaluation

  • Momentan prøve

  • 8 timer

  • 24 timer

  • flere dage

  • Små variationer over året

  • 8-24 timers prøve tilstrækkelig

Monterey 2010


Postere og stande
Postere og stande Evaluation

Monterey 2010


Og m der
-og Evaluation møder

Monterey 2010


Chlorerede ol sningsmidler nyheder fra konferencen i monterey
ZVI Evaluation

  • Injektion af jern i forskellig størrelse

  • Hydraulisk frakturering meget anvendt

  • Dokumentationen måske ikke helt i top

  • Diskussion af brugen af nZVI ikke på programmet

    • Hvordan håndteres nZVI ?

    • Hvilke risici er der i forhold til miljøet ?

    • Hvordan influerer div. coatings på holdbarhed osv. ?

Monterey 2010


Chlorerede ol sningsmidler nyheder fra konferencen i monterey1
Chlorerede Evaluationoløsningsmidler, Nyheder fra konferencen i Monterey

  • Hvad er nyt på området?

  • Hvad er i udvikling?

  • Hvor ser det ud til, at vi er på rette vej?

  • Og hvor skal vi prøve andre teknologier?

  • Hvilke spændende udfordringer kunne vi overveje at tage op i fremtiden?

Monterey 2010