1 / 42

GS2060/TL260GS Product Technical Training

GS2060/TL260GS Product Technical Training. GS2060/TL260GS – Product Overview. GS2060. GS2060 GSM/GPRS Wireless Alarm Communicator. Overview: The GS2065 provides primary or backup GSM/GPRS communication for Power Series PC1864/1832/1616 control panels. Specifications:

dylan
Download Presentation

GS2060/TL260GS Product Technical Training

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. GS2060/TL260GS Product Technical Training 2-Way Wireless Security Suite

  2. GS2060/TL260GS – Product Overview 2-Way Wireless Security Suite

  3. GS2060 GS2060 GSM/GPRS Wireless Alarm Communicator Overview: The GS2065 provides primary or backup GSM/GPRS communication for Power Series PC1864/1832/1616 control panels • Specifications: • Dimensions : 3.937"x5.875"x0.625" • (100mmx150mmx15mm) • Weight : 310 g • Antenna Gain : 2db • Input Voltage : 11.1 to 12.6 V (from the Panel Bell output) • Current Draw : 65 mA at 12V (400 mA • during the GSM transmission) • Operating Environment : 5 º C to 40º C • (40º F to 104º F) 2-Way Wireless Security Suite

  4. GS2060 GS2060 GSM/GPRS Wireless Alarm Communicator • Features: • Back up and primary GSM/GPRS alarm communication • Panel remote uploading/downloading support via GSM/GPRS • Individual Periodic Test Transmission via GSM/GPRS • Supervision heartbeats via GSM/GPRS • 128-bit AES encryption over GSM/GPRS • Full event reporting • SIA format • PC-Link connection • SIM card included • Signal strength and trouble display • Activating and initializing through Connect 24 • Quad-Band: 850 MHz, 1900 MHz, 900 MHz • and 1800 MHz 2-Way Wireless Security Suite

  5. GS2060 Compatible Control Panel & Cabinet Control panel: Power Series PC1864/1832/1616 version 4.1 and higher Cabinet: PC5003C and PC4050C Compatible Receivers: Sur-Gard System I Receiver: version 1.10 and higher Sur-Gard System II Receiver: version 2.00 and higher Sur-Gard SG-DRL3-IP: version 2.20 and higher (for Sur-Gard System III Receiver) Product Model and Accessories: GS2060GS-USA: For US market with AT&T SIM card GS2060GS-CDN: For Canada market with Roger SIM card GS-15ANTQ: Antenna Extension Kits with 15 feet cable GS-25ANTQ: Antenna Extension Kits with 25 feet cable GS-50ANTQ: Antenna Extension Kits with 50 feet cable GS2060 GSM/GPRS Wireless Alarm Communicator 2-Way Wireless Security Suite

  6. TL260GS TL260GS Internet and GSM/GPRS Dual-Path Alarm Communicator Overview: The TL260GS is an Internet and GSM/GPRS Dual-Path alarm communication for Power Series PC1864/1832/1616 control panels • Specifications: • Dimensions : 3.937"x5.875"x0.625" • (100mmx150mmx18mm) • Weight : 320 g • Antenna Gain : 2db • Input Voltage : 11.1 to 12.6 V (from the Panel Bell output) • Current Draw : 100 mA at 12V (400 mA • during the GSM transmission) • Operating Environment : 5 º C to 40º C • (40º F to 104º F) 2-Way Wireless Security Suite

  7. TL260GS TL260GS Internet and GSM/GPRS Dual-Path Alarm Communicator • Features: • Fully redundant Internet and GSM/GPRS dual-path alarm communication • Integrated call routing • Panel remote uploading/downloading support via GSM/GPRS and Internet • Individual Periodic Test Transmission via GSM/GPRS and Internet • Supervision heartbeats via GSM/GPRS and Internet • 128-bit AES encryption via GSM/GPRS and Internet • Full event reporting • SIA format • PC-Link connection • SIM card included • Signal strength and trouble display • Activating and initializing through Connect 24 • Quad-Band: 850 MHz, 1900 MHz, 900 MHz and 1800 MHz 2-Way Wireless Security Suite

  8. TL260GS Compatible Control Panel: Control panel: Power Series PC1864/1832/1616 version 4.1 and higher Cabinet: PC5003C and PC4050C Compatible Receivers: Sur-Gard System I Receiver: version 1.10 and higher Sur-Gard System II Receiver: version 2.00 and higher Sur-Gard SG-DRL3-IP: version 2.20 and higher (for Sur-Gard System III Receiver) Product Model and Accessories: TL260GS-USA: For US market with AT&T SIM card TL260GS-CDN: For Canada market with Roger SIM card GS-15ANTQ: Antenna Extension Kits with 15 feet cable GS-25ANTQ: Antenna Extension Kits with 25 feet cable GS-50ANTQ: Antenna Extension Kits with 50 feet cable TL260GS Internet and GSM/GPRS Dual-Path Alarm Communicator 2-Way Wireless Security Suite

  9. UL Approval List GS2060 GSM/GPRS Wireless Alarm Communicator TL260GS Internet and GSM/GPRS Dual-Path Alarm Communicator • UL Commercial Burglary • Listed as a primary communication channel (heartbeats must be enabled) • Listed as a back-up in conjunction with the POTS (daily test transmission) • Used as Dual Signaling Line Communication System (redundancy must be enabled) • Used as Standard Line Security and Encrypted Line Security System (heartbeats • and encryption must be enabled) • UL Residential Burglary and Fire • Listed as a primary communication channel (monthly test transmission) • Listed as a back-up in conjunction with the DACT (monthly test transmission) 2-Way Wireless Security Suite

  10. ULC Approval List GS2060 GSM/GPRS Wireless Alarm Communicator TL260GS Internet and GSM/GPRS Dual-Path Alarm Communicator • ULC Commercial Burglary and Fire • Listed as a passive communication module with Security Level P1, P2 and P3 (redundancy must be enabled) • Listed as a active communication module with Security Level A1-A4 (heartbeats and encryption must be enabled) • ULC Residential Burglary and Fire • Listed as a primary communication channel (daily test transmission) • Listed as a back-up in conjunction with the DACT (daily test transmission) 2-Way Wireless Security Suite

  11. UL/ULC Listed Installation – Commercial Supervisory/Test Transmission Requirements NOTE: Proper Supervisory/Test Transmission intervals could be pre-set with the profile in Connect 24 database for applicable installations. 2-Way Wireless Security Suite

  12. UL/ULC Listed Installation – Residential Supervisory/Test Transmission – Requirements NOTE: Proper Supervisory/Test Transmission intervals could be pre-set with the profile in Connect 24 database for applicable installations. 2-Way Wireless Security Suite

  13. GS2060/TL260GS – Installation and programming 2-Way Wireless Security Suite

  14. Installation GS2060/TL260GS Installation • BEFORE YOU BEGIN • Have the following ready before installation: • PC1864/1832/1616 Control panel with backup battery • Battery connection harness • PK5500 keypad with battery • Screwdriver • Prior to installing a GS2060 and TL260GS, contact your monitoring station to determine if it is a master reseller or visit www.connect24.com and become an authorized dealer. In both instances, you will acquire a Profile Number, Installer ID Number and an Installer Password. • Please NOTE: • You need to activate the SIM card and initialize the communicator (step 1) 24 HOURS BEFORE INSTALLATION. • All options of the communicator only could be programmed through Connect 24 2-Way Wireless Security Suite

  15. Installation GS2060/TL260GS Installation Summary of Installation Steps Step 1 – Initialize an account via Connect 24 Website (www.connect24.com) Step 2 – Install and wire the communicator to the control panel (on-site) Step 3 – Load the programming and test for best signal strength location Step 4 – Program communication options on the control panel via keypad Step 5 – Test communication 2-Way Wireless Security Suite

  16. Installation GS2060/TL260GSInstallation • Step 1 – Initialize an account via Connect 24 Website (www.connect24.com) • Login to Connect 24 website by using Installer ID and Password to initialize an account • Select Profile Number • Select Product Model • Enter SIM card number • Enter DNIS number (if necessary) • Enter Account Code • Select GPRS Periodic Test Transmission Interval (if necessary) • Select Supervisory Type (if necessary) • Enable DHCP (if necessary) • Enter IP Address (TL260GS only when the installation is static IP) • Enter Subnet Mask Address (TL260GS only when the installation is static IP) • Enter Gateway Address (TL260GS only when the installation is static IP) • Select Ethernet Periodic Test Transmission Interval (if necessary) • Select Rate Plan • Confirm information and submit activation application • NOTE: You still can remotely change these options later via Connect 24 website. 2-Way Wireless Security Suite

  17. Installation GS2060/TL260GS Installation Step 1 – 1 Select Profile Number 2-Way Wireless Security Suite

  18. Installation GS2060/TL260GSInstallation Step 1 – 2 Select Module Number 2-Way Wireless Security Suite

  19. Installation GS2060/TL260GSInstallation Step 1 – 3 Enter SIM Number 2-Way Wireless Security Suite

  20. Installation GS2060/TL260GSInstallation • Step 1 – 4 • Enter DNIS number • Enter Account Code • Select Supervisory Type • Enable DHCP (if necessary) 2-Way Wireless Security Suite

  21. Installation GS2060/TL260GSInstallation • Step 1 – 5 • Enter IP Address (TL260GS only) • Enter Subnet Mask Address (TL260GS only) • Enter Gateway Address (TL260GS only) 2-Way Wireless Security Suite

  22. Installation GS2060/TL260GSInstallation • Step 1 – 6 • Select Plan Rate 2-Way Wireless Security Suite

  23. Installation GS2060/TL260GSInstallation • Step 2 – 1 Install and wire the communicator to the control panel (on-site) • Assemble the communicator with mounting bracket 2-Way Wireless Security Suite

  24. Installation GS2060/TL260GSInstallation • Step 2 – 2 Install and wire the communicator to the control panel (on-site) • Insert the communicator into the cabinet and assemble the antenna 2-Way Wireless Security Suite

  25. Installation GS2060/TL260GSInstallation • Step 2 – 3 Install and wire the communicator to the control panel (on-site) • Wire the communicator to control panel • NOTE: See details in product manual for PC1864/1832/1616 control panel • PCLINK Cable Connector • Control panel: Red wire is on the right and black is on the left • Communicator: Must be reversed (Black wire is on the right and red wire is on the left) 2-Way Wireless Security Suite

  26. Installation GS2060/TL260GS Installation Step 3 – Load the programming and test for best signal strength location Ensure the SIM card is inserted Power up the control panel The communicator will be programmed by loading the pre-programmed configuration from Connect 24 automatically Check Green LEDs. You must achieve full or medium signal strength. See details in product manual. If signal strength is poor, must relocate the control panel or use an external extension antenna kits 2-Way Wireless Security Suite

  27. GS2060/TL260GSInstallation Installation • Step 4 – Program communication options on the control panel via keypad • GS2060/TL260GS with PC1864/1832/1616 control panel • o Sections [301], [302], [303]: Program Communication Path • • DCAA - Internal (Ethernet 1, Ethernet 2, GPRS 1, • GPRS 2) • o Section [350] : Program Communication Format (Communicator) • • (If Option [301] (above) is set to DCAA, Option [350] must be • set to SIA, sub-option 5) • o Sections [351] to [376] : Program Call Direction • o Section [382] : Enable T-LINK Interface (Option [5]) • o Section [167] : Enable Communication Wait For ACK (Set to 60 seconds) • o Section [401] : Enable DLS Session Through GPRS or Ethernet (Option [1]) 2-Way Wireless Security Suite

  28. Installation GS2060/TL260GSInstallation • Step 5 – Test communication • 1. Disconnect incoming phone line from TIP and RING on the control panel • 2. Verify that LED 2 is on, this indicate that the unit is active • 3. Create an alarm transmission • 4. Verify alarm transmission by calling monitoring station • 5. Re-connect the phone line, if necessary • For back-up communication applications, perform steps 1 to 5 • For primary communication applications, perform steps 3 and 4 only 2-Way Wireless Security Suite

  29. LED Display Installation • Trouble Status LED (Yellow – first one from the left) • Please see details about the trouble shooting on page 17 in product manual 2-Way Wireless Security Suite

  30. LED Display Installation • Network Connection Status LED (Red – second one from the left) • LED OFF • No network connection issue present • LED ON • Physical Ethernet cable is not connected • DHCP configuration fails • Fails to get an IP address from the GPRS network • GPRS connections has been reset • LED blinks quickly once • Ethernet transmitting • LDE blinks quickly twice • Ethernet receiving 2-Way Wireless Security Suite

  31. LED Display Installation • Signal Strength LED 2 (Green – third one from the left) • Signal Strength LED 1 (Green – fourth one from the left) • Green LED 2 blinks quickly once • GPRS transmitting • Green LED 2 blinks quickly twice • GPRS receiving 2-Way Wireless Security Suite

  32. Keypad Trouble Display Installation • Trouble Condition • General System Trouble • Panel Event Buffer Description • T-Link Network Fault/Restore includes • SIM Lock Trouble • GSM Trouble • Ethernet Trouble • Connect 24 Configuration Trouble • T-Link Receiver Trouble/Restore includes • Receiver Not Available Trouble • Receiver Supervison Trouble • FTC Trouble • T-Link Comm. Fault/Restore includes • Panel Absent Trouble 2-Way Wireless Security Suite

  33. GS2060/TL260GS – Applications 2-Way Wireless Security Suite

  34. Applications GS/IP Call Routing (Internal) • Communicator Controlled Call Routing • – Backup (dual-path) • – Redundant (dual-path) • Required Programming • Panel Sections [301], [302] and [305] • • Any of them could be programmed as DCAA • DCAA (default): Ethernet 1 → Ethernet 2 → GRPS 1 → GPRS 2 • Communicator Sections [005] • Option [4] - Primary and backup path • [ON]: GPRS path primary, Ethernet path backup • [OFF]: Ethernet path primary, GPRS path backup • Option [5] - Redundant between GPRS path and Ethernet path • [OFF]: Disable redundancy • [ON]: Enable redundancy • NOTE: “Primary and Backup Path” and “Redundant Communication” options need to be configured during the initialization of the account via Connect 24. 2-Way Wireless Security Suite

  35. Applications GS/IP Call Routing (Internal) Backup Mode 1: Ethernet Primary, 4 Receivers 2-Way Wireless Security Suite

  36. Applications GS/IP Call Routing (Internal) Backup Mode 2: Ethernet Primary, 2 Receivers 2-Way Wireless Security Suite

  37. Applications GS/IP Call Routing (Internal) Backup Mode 3: GPRS Primary, 4 Receivers 2-Way Wireless Security Suite

  38. Applications GS/IP Call Routing (Internal) Backup Mode 4: GPRS Primary, 2 Receivers 2-Way Wireless Security Suite

  39. Applications GS/IP Call Routing (Internal) Redundant Mode: 4 Receivers – (Redundancy between GSM/GPRS path and Ethernet/Internet path) NOTE: The application requires 4 different SG receivers or SG-DLR3 IP line cards 2-Way Wireless Security Suite

  40. Applications Other Applications • Periodic Test transmission • Individual periodic test via GPRS and Ethernet • Daily, Weekly and Monthly Interval • Configured during the initialization of the account via Connect 24 • Encryption • 128 Bit AES Encryption • Turned on by central monitoring station Sur-Gard receiver • Encrypted communications enabled after next event sent to the receiver • NOTE: Enabling this feature will require more data usage. • Read-only Options from Keypad • Read all the options of the communicator from LCD keypad • Control panel option [851] 2-Way Wireless Security Suite

  41. Applications Other Applications • Power Save Mode • Extend the battery duration when an AC power loss on control panel • Ethernet functionality turned off until a new event need to be transmitted • Network Connections LED: OFF • Incoming DLS connection will not be possible • Hardware Default • Reset the programming options to the factory setting (default values) • NOTE: Please see details in product manual • Software Update • Update the firmware through DLS IV locally via PCLINK • Update the firmware through DLS IV remotely via Ethernet/Internet (TL260GS only) 2-Way Wireless Security Suite

  42. Applications SIA Report Code Event SIA Data Code SIA Address Field Panel Absent Trouble ET 001 Panel Absent Trouble Restore ER 001 Radio Activation Restore RS 001 Ethernet 1 Test Transmission RP 001 GPRS 1 Test Transmission RP 003 GPRS 2 Test Transmission RP 004 FTC Restore YK 001 Example: Nri0 ET001 N= New Event ri0=Partition/Area identifier ET= Panel Absent Restore 001=Zone 001 NOTE: GPRS 2 Test Transmission will only be sent when two different APNs are programmed. 2-Way Wireless Security Suite