二電廠 2012 年度 OQA DPPM 報告

二電廠 2012 年度 OQA DPPM 報告. 5 月份 OQC 退貨 6 件 : 1. FSA011-030G I/O Label 用錯整批  分析 : 舊 label 沒有清理造成錯用 . 對策 : 領班接到材料 EC 通知必須把線上材料清掉 2. API1PC01-311G 漏取檢修控制卡 1 臺  分析 : 貼標簽人員掃描后漏取 . 對策 : 后續包裝人員要先檢查單體外觀 . 3. FSA011-030G CYCLE DROPOUT 測試不良 1 臺  分析 : M201 來料 (D/C1149) 差異 , VFB 漂移偏下限 .

duncan
Download Presentation

二電廠 2012 年度 OQA DPPM 報告

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 二電廠2012年度OQA DPPM報告 5月份OQC退貨6件: 1. FSA011-030G I/O Label 用錯整批分析: 舊label 沒有清理造成錯用. 對策: 領班接到材料 EC 通知必須把線上材料清掉 2. API1PC01-311G 漏取檢修控制卡1臺分析: 貼標簽人員掃描后漏取. 對策: 后續包裝人員要先檢查單體外觀. 3. FSA011-030G CYCLE DROPOUT測試不良1臺分析: M201來料(D/C1149)差異, VFB漂移偏下限. 對策: 在L/D前 SORTING 小板 ,將M201VFB電壓偏低不良提前篩選出來. 4. FSA011-030G 機殼漏鎖螺絲 1 臺. 分析: 修外觀沒按回線流程作業. 對策: 不良單體必須嚴格按回線流程作業. 5. FSB004-4B0G 測試不開機 1臺. 分析: 12V 短路時會有機會影響到同步整流的時序. 對策: 全橋 MOS 的 Gate 電阻由 20 ohm 改為 47 ohm 6. FSA022-790G 漏鎖螺絲1臺. 分析: 領班沒有合理使用螺絲盤, 少鎖螺絲也不知道. 對策: 合理使用螺絲盤, 以用量的倍數的管控