OBIECTIVELE PRINCIPALE ALE LECŢIEI:

EXECUTAREA LEG ĂTURILOR FUNCŢIONALE ÎNTR-O INSTALAŢIE ELECTRICĂ DE ILUMINAT . OBIECTIVELE PRINCIPALE ALE LECŢIEI:. O1. Identificarea şi precizarea rolului fiecărui element al instalaţiei electrice de iluminat. O2. Cunoaşterea metodologiei de executare a conexiunilor în doze.

dolan
Download Presentation

OBIECTIVELE PRINCIPALE ALE LECŢIEI:

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. EXECUTAREA LEGĂTURILOR FUNCŢIONALE ÎNTR-O INSTALAŢIE ELECTRICĂ DE ILUMINAT OBIECTIVELE PRINCIPALE ALE LECŢIEI: O1. Identificarea şi precizarea rolului fiecărui element al instalaţiei electrice de iluminat. O2. Cunoaşterea metodologiei de executare a conexiunilor în doze. O3.Înţelegerea principiului de funcţionare şi a metodologiei de verificare a instalaţiei electrice de iluminat.

  2. 1. MATERIALE NECESARE REALIZĂRII INSTALAŢIEI DE ILUMINAT TUB DE PROTECŢIE DOZĂ DE RAMIFICAŢIE CONDUCTOARE

  3. 2. APARATE NECESARE REALIZĂRII INSTALAŢIEI DE ILUMINAT ÎNTRERUPĂTOR SIMPLU ÎNTRERUPĂTOR DUBLU DULIE SIURANŢE FUZIBILE

  4. 3. CONSTRUCŢIA ŞI ROLUL APARATELOR ELECTRICE a. DULIA I II III II I III I. MANTAUA DULIEI II. MIEZUL DULIEI CU CONTACTE ŞI CLEME DE LEGĂTURĂ III. INELUL DULIEI ROL: FIXEAZĂ LAMPA ELECTRICĂ ŞI PERMITE ALIMENTAREA CU ENERGIE A LĂMPII

  5. b. ÎNTRERUPĂTORUL SIMPLU III I II I. CLAPETA ÎNTRERUPĂTORULUI II. SOCLUL ÎNTRERUPĂTORULUI (VEDERE FAŢĂ) III. SOCLUL ÎNTRERUPĂTORULUI (VEDERE SPATE) ROL: ÎNCHIDE SAU DESCHIDE CIRCUITUL DE ALIMENTARE AL LĂMPII ELECTRICE

  6. c. ÎNTRERUPĂTORUL DUBLU I II III I. CLAPETELE ÎNTRERUPĂTORULUI II. SOCLUL ÎNTRERUPĂTORULUI (VEDERE FAŢĂ) III. SOCLUL ÎNTRERUPĂTORULUI (VEDERE SPATE) ROL: ÎNCHIDE SAU DESCHIDE CIRCUITELE DE ALIMENTARE ALE LĂMPILOR ELECTRICE

  7. d. SIGURANŢA FUZIBILĂ I II III I. CORPUL SIGURANŢEI II. PATRONUL SIGURANŢEI III. CAPACUL SIGURANŢEI ROL: PROTEJEAZĂ INSTALAŢIA LA SCURTCIRCUIT

  8. 4.1. IDENTIFICAREA ELEMENTELOR SCHEMEI DE PRINCIPIU1 H1 H1 H3 H2 H2 H3 Doza Doza K K e e

  9. 4.2. IDENTIFICAREA ELEMENTELOR SCHEMEI DE PRINCIPIU2 H3 H1 H2 e Doza2 Doza1 Doza3 K2 K1 H2 H3 H1 Doza1 Doza2 e Doza3 K2 K1

  10. 5.1. VERIFICAREA APARATELOR - PANOPLIA1

  11. 5.1. VERIFICAREA APARATELOR - PANOPLIA1

  12. 5.1. VERIFICAREA APARATELOR - PANOPLIA1

  13. 5.2. VERIFICAREA APARATELOR – PANOPLIA2

  14. 5.2. VERIFICAREA APARATELOR – PANOPLIA2

  15. 5.2. VERIFICAREA APARATELOR – PANOPLIA2

  16. 6. EXECUTAREA CONEXIUNILOR ÎN DOZE – PANOPLIA1 H1 CL CF 3 H2 H3 1 CF CL CL CF 4 2 H1 K1-1 K1-2 K1-1 ---- H1 K1-2 ---- H2+H3 H2 H3 K1 N F N F

  17. 7. EXECUTAREA CONEXIUNILOR ÎN DOZE – PANOPLIA2 H1 H2 H3 CL CL CF CF CL CF F F F 7 9 4 8 N N N 3 2 5 1 6 K1-1 ----- H1 K1-2 ----- H2 K2 ----- H3 K2 K1-2 K1-1 H1 H2 H3 F N K1 K2

  18. 9.1. SCHEMA ELECTRICĂ MONOFILARĂ - PANOPLIA1

  19. 9.2. SCHEMA ELECTRICĂ MONOFILARĂ – PANOPLIA2

  20. 10. SDV-uri NECESARE EXECUTĂRII ŞI VERIFICĂRII LUCRĂRII

  21. 11. NTSM SPECIFICE • LA EFECTUAREA LUCRĂRILOR SE UTILIZEAZĂ SCULE CU MÂNERE DIN MATERIALE ELECTROIZOLANTE, CORESPUNZĂTORE NORMELOR DE ELECTROSECURITATE. • RACORDURILE DINTRE PĂRŢILE COMPONENTE ALE UNUI MONTAJ SE VOR FACE, ÎN MOD OBLIGATORIU, PRIN CONDUCTOARE PERFECT IZOLATE. • ÎNAINTE DE ALIMENTAREA CU TENSIUNE A UNUI MONTAJ, SE VA FACE O VERIFICARE GENERALĂ A APARATELOR, LEGĂTURILOR, IZOLAŢIEI, ETC. • ÎN TIMPUL FUNCŢIONĂRII MONTAJULUI, ESTE INTERZISĂ ATINGEREA PĂRŢILOR NEIZOLATE, SCHIMBAREA LEGĂTURILOR, ATINGEREA ŞI ÎNLOCUIREA BECURILOR. • DUPĂ TERMINAREA EXPERIENŢELOR, MONTAJUL VA FI SCOS OBLIGATORIU DE SUB TENSIUNE.

  22. TEST DE VERIFICARE H1 CL CF H2 H3 CF CL CL CF K1 K2 K1 – H2 K2 – H1+H3 N F 0 1 2