AnalogLinks
Download
1 / 1

Network Connection to the ZEUS Event Builder (~50 Hz) - PowerPoint PPT Presentation


  • 120 Views
  • Uploaded on

AnalogLinks. AnalogLinks. AnalogLinks. NIM + Latency. NIM + Latency. NIM + Latency. HELIX Driver Front-end. The ZEUS Microvertex Data Acquisition and Global Track Trigger. Forward Tracking, Straw Tube Tracker TP-Readout. Central Tracking Detector TP-Readout.

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about 'Network Connection to the ZEUS Event Builder (~50 Hz)' - diata


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
Network connection to the zeus event builder 50 hz

AnalogLinks

AnalogLinks

AnalogLinks

NIM +

Latency

NIM +

Latency

NIM +

Latency

HELIX

Driver Front-end

The ZEUS Microvertex Data Acquisition and Global Track Trigger

Forward Tracking,

Straw Tube Tracker

TP-Readout

Central Tracking

Detector TP-Readout

Global First

Level Trigger,

Busy, Error

MVD HELIX Front-End & Patch-Boxes

Analog Data

MVD VME Readout

NIM +

Latency

NIM +

Latency

NIM +

Latency

Clock +

Control

Clock+

Control

Master

Clock+

Control

Lynx

OS

CPU

Lynx

OS

CPU

Lynx

OS

CPU

Lynx

OS

CPU

Lynx

OS

CPU

Lynx

OS

CPU

ADCM

modules

ADCM

modules

ADCM

modules

STT 2TP module

CTD 2TP modules

CTD 2TP modules

Lynx

OS

CPU

VME TP connection

Data from STT

VME TP connection Z by Timing CTD data

VME (C+C Slave)

Crate 2 (MVD forward)

VME (C+C Slave)

Crate 1 (MVD bottom)

VME (C+C Master)

Crate 0 (MVD top)

VME TP connection

Axial/Stereo CTD data

VME HELIX Driver Crate

NIM +

Latency

Lynx

OS

CPU

GSLT 2TP modules

GTT Control +

Fan-out

Global Tracking Trigger Processors (GFLT rate ~500 Hz)

TP connection to the Global Second Level Trigger

Fast Ethernet/

Gigabit Network

ZEUS Run Control and Online

Monitoring Environment

Global Second

Level Trigger Decision

NIM +

Latency

Lynx

OS

CPU

Slow control +

Latency Clock modules

VME CPU Boot Server and Control

Network Connection to

the ZEUS Event Builder (~50 Hz)

Main MVDDAQ server, Local Control, Event-Builder Interface