1 / 19

TEST GRAINS AS A NOVEL DIAGNOSTIC TOOL

TEST GRAINS AS A NOVEL DIAGNOSTIC TOOL. B.W. James, A.A. Samarian and W. Tsang School of Physics, University of Sydney NSW 2006, Australia B.James@physics.usyd.edu.au ICPP Sydney 2002. What is a dusty plasma?.

deion
Download Presentation

TEST GRAINS AS A NOVEL DIAGNOSTIC TOOL

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. TEST GRAINS AS A NOVEL DIAGNOSTIC TOOL B.W. James, A.A. Samarian and W. Tsang School of Physics, University of Sydney NSW 2006, Australia B.James@physics.usyd.edu.au ICPP Sydney 2002

  2. What is a dusty plasma? • a low temperature plasma containing small particles of diameters in nanometer and micrometer range • particles acquire a net negative charge (at equilibrium floating potential) • particles levitated in sheaths where electric force balances gravity • particles can form liquid- and solid- like arrays (plasma or Coulomb crystal) which can undergo phase transitions

  3. Forces on dust particle in plasma sheath ions vi sheath boundary FE, Fth E radius = a charge = Zd hb z Fg, Fi heq rf powered electrode Figure 1: Schematic diagram of dust particle in plasma sheath

  4. Forces on a dust particle • Electric force • Gravity force • Ion drag force • Thermophoretic force

  5. where • a is particle radius • r is particle density • Zde is charge on particle • mi is ion mass • ni is ion density • vi in ion velocity in sheath • Te is electron temperature • T is gas temperature • m is mass of gas atoms • k is thermal conductivity of plasma

  6. Experimental arrangement Figure 2: Experimental chamber and image of test dust particles levitated above the electrode. The test grains are generated in the discharge (power up to 200W, pressure upto 1 torr) by electrode sputtering.

  7. Equilibrium position of dust particle Using the force balance equation, FE + Fg + Fi + Fth = 0 the equilibrium position has been calculated as a function of radius a (see figure 3) using following assumptions • Vs ~ 60 V, linear variation of electric field in sheath • vi from sheath model • Te ~ 2 eV • R = 2 g cm-3 • dT/dz ~ 1-5 K cm-1 (varying with input power) • Zd calculated from OML theory

  8. Equilibrium position vs. radius wi = 106 s-1 (dashed) 5x106 s-1 (dotted), 107 s-1 (solid), Figure 3: Equilibrium height of dust particles above electrode heq, relative to height of sheath boundary hb as a function particles radius for several values of ion plasma frequency,

  9. Alternative estimates of sheath width Figure 4: Electron temperature Te (points with error bars) measured using Langmuir probe; discharge emission (solid line); the dashed line shows the equilibrium position (heq =10.8 mm) of test grains (a~350 nm). Discharge conditions: p = 90m Torr, P = 80 W.

  10. Sheath width as function of pressure Position of sheath edge (hb) vs pressure at different rf-input powers 30 (mm) – 35W b h 25 – 60W – 100W 20 15 10 5 0 0 10 20 30 40 50 60 70 80 90 100 Pressure (mTorr)

  11. Visualisation of rf sheath • Sufficiently small particles cannot achieve force equilibrium in the sheath - the sheath becomes a particle-free region • Particles occupy pre-sheath and positive column • Provides a visualisation of the sheath-plasma boundary - see Figure 5

  12. Figure 5: The shape of the potential well above the confining electrode in a radio-frequency (rf) discharge with a printed-circuit board electrode system (Cheung et al., 2002) was visualised using fine dust grains that were generated in the discharge. The well shape was found to depend strongly on the confining potential

  13. Transient motion technique Side Observation Window Top View Top Observation Window Particle Dispenser Top Ground Electrode DC Power AC Power Pin Electrodes Particle Driving Pad where Gas Inlet Where is the resonant frequency And is the electric field gradient RF Supply 15MHz

  14. Effect of hot electrons in sheath Figure 6: Square root of distance of particle from sheath edge as a function of particle radius

  15. Particle Data Probe Data Figure 7: Potential profile measured by a Langmuir probe, and by transient motion analysis

  16. Conclusions • as particle radius decreases, equilibrium position moves closer to edge of sheath • sufficiently small particles avoid sheath region, occupying pre-sheath and positive column. providing visualisation of sheath • hot electrons affect equilibrium position • potential and electric filed profiles determined from transient motion analysis Acknowledgements This work is supported by the Australian Research Council and the Science Foundation for Physics within the University of Sydney References A.A. Samarian and B.W. James, Phys Letters A, 287 (2001) 125 F. Cheung, A. Samarian and B. James, Physica Scripta, T98 (2002) 143-5

  17. Particle Data Probe Data Figure 8: Radial electric field derived from results in figure 7. Least Mean Square Fit for Particle Data Least Mean Square Fit for Probe Data