1 / 14

Precision Drift Chambers for the ATLAS Muon Spectrometer

Abstracts: 344,350,646. Precision Drift Chambers for the ATLAS Muon Spectrometer. Susanne Mohrdieck Max-Planck-Institut f. Physik, Munich for the ATLAS Muon Collaboration. International Europhysics Conference on High-Energy Physics 17.-23.7.2003. Outline:

debbie
Download Presentation

Precision Drift Chambers for the ATLAS Muon Spectrometer

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Abstracts: 344,350,646 Precision Drift Chambers for the ATLAS Muon Spectrometer Susanne Mohrdieck Max-Planck-Institut f. Physik, Munich for the ATLAS Muon Collaboration International Europhysics Conference on High-Energy Physics 17.-23.7.2003 Outline: • Introduction - ATLAS and the muon spectrometer • Precision chamber production • Monitoring and measurement of chamber quality/accuracy • Performance test of precision chambers under LHC operating conditions

  2. The ATLAS Muon Spectrometer ATLAS at LHC: multi-purpose detector to search for Higgsand new physics • Muon Spectrometer: • toroidal magnetic field: <B> = 0.4 T •  high pt-resolution independent • of the polar angle • size defined by large lever arm to • allow high stand-alone precision • air-core coils tominimise the • multiple scattering • 3 detector stations • - cylindrical in barrel • -wheels in end caps • coverage: || < 2.7 • used technologies: • fast trigger chambers: • TGC,RPC • high resolution tracking • detectors: MDT, CSC

  3. see talk by C.Amelung Performance goal: high stand-alone µ-momentum resolution of 2-10% ! at 1TeV: = 10%  sagitta = 500 µm elaborate optical alignment system to monitor chamber deformations and displacements chamber resolution: 50 µm  monitoring of high mechanical precisionduring production in this talk

  4. Monitored Drift Tube Chambers (MDT) • 6 / 8 drift tube layers,arranged in • 2 multilayersglued to a spacer frame • length: 1 – 6 m, width: 1 – 2 m • optical system to monitor chamber • deformations • gas: Ar:CO2 (93:7) to prevent aging, 3 bar • chamber resolution: 50 µm • single tube resolution: 100 µm • required wire position accuracy: 20 µm Barrel End Cap

  5. Status of MDT Production • production at 13 sites in 7 countries: • assembly layer by layer using • precision table with precise ‚combs‘ • on-line monitoring of temperature • and mechanical movements MPI Munich Plan for Bare Chambers Bare Chambers Chambers with Services • production within schedule: • 58% of 1194 chambers assembled • will be finished middle of 2005

  6. tube wall: 0.4 mm Al 30 mm diameter endplug wire: 50 µm W-Re Drift Tube Production MDT chambers consist of up to 432 drift tubes: • precise wire positioning • in the endplugs: • rms of 7µm production at NIKHEF • automated wiring machine • elaborate quality checks • total rejection ofonly 2.6% • 73% of in total 370.000 tubes • produced

  7. Wire Positions with a X-Ray Method measurement of the intensity as function of the motor position X-tomograph at CERN accuracy of wire position measurement: 3 µm mechanical precision measured with X-ray method selected chambers tested: 74 of 650 chambers produced at 13 sites scanned sofar average wire positioning accuracy: 15 µm

  8. Monitoring of Chamber Quality monitoring of the chamber parameters by optical sensors during the production (e.g. MPI f. Physik, Munich) X-rayed MPI chambers 20 µm • stable over time • agreement with X-ray method 40 µm

  9. Monitoring of Wire Positions • combination of all monitoring results: • - chamber parameters • - tube positions within a tube layer • wire positions within the tube wire positions inallchambers deviations of monitoring to X-ray method • good agreement between X-ray • method and monitoring results • y = ymonitoring – yX-ray • - average rms(y) = 19 µm MPI • comparison to nominal positions: • - stable wire positioning accuracy • - average rmsy = 18 µm rms of deviations from nominalpositions in the monitoring (MPI) required accuracy achieved <rmsy> = 18 µm

  10. CosmicRay Test e.g. Test Facility at the University of Munich • goals: • check functionality of all • tubes and electronics channels • measurement of wire positions y z • deviations from nominal positions compared • to X-ray results: rmsy = 25 µm, rmsz = 9 µm

  11. 10 µm CosmicRay Test (cont) • good agreement with X-ray • results • extraction of layer positions • with high precision: 2 µm in z • 4 µm in y z displacement for the tube layers 0.4 µm • precision for z-pitch: • 0.3 µm per layer z-pitch for the tube layers University of Munich

  12. Performance under LHC Conditions • operation atunprecedentedly • high n and  background rates: • 8 – 100 s-1cm-2 • performance test of a large 6-layer chamber: • high energy µ beam (100 GeV) • -ray irradiation (Cs-137 source with 740 GBq) • external reference (silicon beam telescope) , Ar:CO2(93:7), 3 bar Single Tube Resolution • required resolution maintained even • at high irradiation: • 104 µm without irradiation • degradation by 10 µm at highest • ATLAS rates of 100 s-1cm-2 degradation due to space charge fluctuations single tube resolution vs. drift radius

  13. Efficiencies extraction of tracking efficiency using the reference track in the Si telescope track-reconstruction efficiency for 4m long tubes • total track-reconstruction efficiency: • ( 99.97 )% without irradiation • ( 99.77 )% at highest ATLAS rate • (for 4m long tubes) +0.03 - 0.9 +0.23 - 0.8 highest ATLAS rate • even at highest expected irradiation no deterioration of track-reconstruction efficiency

  14. Conclusions • Precision MDT chamber production within schedule (58% assembled) • Wire positioning measured with several methods during production •  required accuracy of 20 µm achieved • Performance under LHC conditions tested •  at highest background rates chamber resolution of 50 µm maintained •  no deterioration of track-reconstruction efficiency

More Related