quality air solutions
Download
Skip this Video
Download Presentation
Quality Air Solutions

Loading in 2 Seconds...

play fullscreen
1 / 28

Quality Air Solutions - PowerPoint PPT Presentation


  • 156 Views
  • Uploaded on

Quality Air Solutions. FX1-21 Hot Gas Bypass Refrigerant Dryers. FX1-21 Refrigerant Dryers. Simple Reliability. FX1-21 Refrigerant Dryers. Simple Reliability. Introduction To The New Range Why The Redesign ? Available Range Scope Of Supply Working Principal Features & Benefits

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about 'Quality Air Solutions' - darena


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
quality air solutions

Quality Air Solutions

FX1-21 Hot Gas Bypass Refrigerant Dryers

slide2
FX1-21 Refrigerant Dryers

Simple Reliability

slide3
FX1-21 Refrigerant Dryers

Simple Reliability

  • Introduction To The New Range
  • Why The Redesign ?
  • Available Range
  • Scope Of Supply
  • Working Principal
  • Features & Benefits
  • Approvals & Options
  • Installation
  • Support Material
slide4
FX1-16 Refrigerant Dryers

Why The Redesign?

  • More models – which means closer match to each customer’s demand
  • Increased number of standard features – improved customer benefit
  • Improved performance, more variants and approvals – increased competitive advantage
slide5
FX17-21 Refrigerant Dryers

Why Extend The Range ?

  • The existing FX range is a highly successful product line, reliable and competitive.
  • There’s a genuine market need for simple, good quality dryers in this size range.
  • Having two very different dryer lines enables us to better fight the competition.
slide6
FX17-21 Product Introduction

Completing The Total FX Range

FX17 – 21

March 2008

FX1-5November 2005

FX6-12November 2005

FX13-16November 2006

slide7
FX1-16 Refrigerant Dryers

Product Range

  • Reference Conditions 50Hz :

Ambient temp 25°F

Inlet temp 35°F

Inlet pressure 7 bar(g)

  • Maximum Conditions 50Hz

Ambient temp 43°C

Inlet temp 55°C

Inlet pressure 13 (16) bar(g)

  • Reference Conditions 60Hz :

Ambient temp 100°F

Inlet temp 100°F

Inlet pressure 100 psi(g)

  • Maximum Conditions 60Hz

Ambient temp 110°F

Inlet temp 131°F

Inlet pressure 189 (232) psi(g)

slide8
FX17-21 Refrigerant Dryers

Product Range

  • Maximum Conditions 60Hz

Ambient temp 115°F

Inlet temp 140°F

Inlet pressure 189 psi(g)

  • Reference Conditions 60Hz :

Ambient temp 100°F

Inlet temp 100°F

Inlet pressure 100 psi(g)

slide9
The FX is designed to provide:
  • Full scope with no frills
  • Simple reliability in terms of performance and operation
  • No options, which can complicate the design
  • Industry standard pressure drop

Result

FX1-21 Refrigerant Dryers

The Cost Effective Solution

A cost efficient package, free of design compromises, providing dry air for the majority of compressed air applications.

slide10
FX1-21 Refrigerant Dryers

PDP of 3°C/38°F For A Corrosion Free Process

The FX removes the moisture from the air and with it the risk of damage to equipment, machines and even and final product.

slide11
Inlet and outlet connections on all FX are conveniently positioned on the back of the unit

Industry standard pressured drop

Simple control panel with on/off switch and PDP indicator

Refrigerant circuit sized to always provide dry air

Efficient heat exchanger with air-to-air side chosen for operational reliability and steady performance

Basic scope of supply includes a HGB but remains cost effective

FX1-16 Refrigerant Dryers

Key Features Of The FX Range

slide12
FX17-21 Refrigerant Dryers

Key Features Of The FX Range

Inlet and outlet connections on all FX are conveniently positioned on the back of the unit

Industry standard pressured drop

Simple control panel with on/off switch and PDP indicator

Efficient heat exchanger with air-to-air side chosen for operational reliability and steady performance

Refrigerant circuit sized to always provide dry air

Basic scope of supply includes a HGB but remains cost effective

slide13
FX1-21 Refrigerant Dryers

A Totally Self Regulating Dryer Providing Constant Dry Air

  • Integrated water separator
    • The FX6-21 include an integrated high efficiency water separator, which facilitates a low and reliable pressure dew point
  • Air-to-air heat exchanger
    • All models include an air-to-air heat exchanger as standard, which prevents condensation forming on the outside of the pipe system
slide14
FX1-21 Refrigerant Dryers

A Totally Self Regulating Dryer Providing Constant Dry Air

  • Electronic drain
    • The FX1-21 include an electronic water drain as standard, ensuring reliable evacuation of the water separator, which thereby increasesthe reliability of the total machine
slide15
FX1-21 Refrigerant Dryers

A Totally Self Regulating Dryer Providing Dry Air Constantly

  • Pressure drop
    • Market competitive pressure drop means that every FX customer can reduce cost through energy savings
    • Reducing the pressure requirement and therefore the energy consumption of the compressor, brings bigger savings than most cycling or thermal mass units can achieve
slide16
FX1-5 Brazed Plate Heat Exchanger Dryers

Features and Variants

  • Inlet and outlet connections on the back of the unit
  • HGB supplied on all machines
  • R134a refrigerant
  • Electronic drain as standard
  • Brazed plate heat exchanger with air-to-air side
  • Separate centrifugal water separator
  • Simple control panel with PDP gauge
  • All units available in:
    • 230V 50Hz IEC
    • 230V 60Hz CSA and UL
    • 115V 60Hz CSA and UL (inclusive of plug)
slide17
The unit can be placed next to the wall

FX1-5 Compact and Easy to Install

Features and Variants

slide18
The FX1-5 Brazed plate heat exchanger with air-to-air side

FX1-5 Brazed Plate Heat Exchanger Dryers

A Totally Self Regulating Dryer Providing Constant Dry Air

1. Refrigerant compressor

2. Condenser

3. Condenser fan

4. Capillary filter

5. Capillary tube

6. Refrigerant/air heat exchanger

7. Refrigerant separator

8. Hot gas bypass

9. Air/air heat exchanger

10. Water separator

11. Automatic timer drain

slide19
FX6-16 Refrigerant Dryers

Features and Variants

  • Inlet and outlet connections on the back of the unit
  • HGB supplied on all machines
  • R404a refrigerant
  • Electronic drain as standard
  • Aluminium block heat exchanger with air-to-air side
  • Integrated water separator
  • Simple control panel with PDP gauge
slide20
FX6-16 Refrigerant Dryers

Features and Variants

  • FX6-12 are available in:
    • 230V 50Hz IEC
    • 230V 60Hz CSA and UL
    • 115V 60Hz UL (inclusive of plug)
    • FX6-7 115V 60Hz CSA (inclusive of plug)
  • FX13-16 are available in:
    • 400V 3PH 50 Hz IEC
    • 460V 3PH 60 Hz CUL US
slide21
FX17-21 Refrigerant Dryers

Features and Variants

  • Inlet and outlet connections on the back of the unit
  • HGB supplied on all machines
  • R404a refrigerant
  • Electronic drain as standard
  • Aluminium block heat exchanger with air-to-air side
  • Integrated water separator
  • Simple control panel with PDP gauge
slide22
FX17-21 Refrigerant Dryers

Features and Variants

  • FX17-21 are available in:
    • 400V 3PH 50 Hz IEC
    • 460V 3PH 60 Hz CUL US
slide23
FX6-21 Refrigerant Dryers

A Totally Self Regulating Dryer Providing Constant Dry Air

In FX6-16 Aluminium block heat exchanger with air-to-air side and built-is water separator is used for maximum heat transfer efficiency and reliable water evacuation

1. Refrigerant compressor

2. Condenser

3. Condenser fan

4. Capillary filter

5. Capillary tube

6. Refrigerant/air heat exchanger

7. Refrigerant separator

8. Hot gas bypass

9. Air/air heat exchanger

10. Water separator

11. Automatic drain

slide24
Installing a bypass on the dryer and filters means that servicing can be carried out without disruption the air flow.

The PD after-filter removes much of the remaining oil (0.01ppm) and particles bigger than 0.01 micron.

The DD pre-filter protects the heat exchanger in the dryer, reduces the oil content of the air and removes particles above 1 micron

FX dryer

A “wet” air receiver not only acts as a buffer, but also removes free water, which helps the dryer

Outlet Air Quality

Moisture +3°C/38°F

Particles 0.01 micron

Oil content 0.01 ppm

ISO Class 1.4.1

The use of electronic no loss drains not only saves valuable compressed air, but also reduces the chances of blockages and failures

A condensate separator is necessary to ensure that the drainage system is not polluted with oil

FX1-21 Refrigerant Dryers

Recommended FX Installation Layout

slide25
FX1-21 Product Information

Final Product – Support material

slide26
FX1-21 Refrigerant Dryers

Top 5 Selling Points

  • Simple to install and easy to operate
  • Market standard performance, a good quality machine built to the same high standard as all other Atlas Copco equipment
  • New heat exchanger with integrated air-to-air side eliminates risk of outlet pipes corrosion
  • Integrated water separator reduces components and pressure drop whilst increasing reliability
  • Electronic drain ensures proper operation of the water separator and increases overall reliability
slide27
We are committed to your superior productivity throughinteraction and innovation.
ad