1 / 15

Anhydrous Ammonia 1005

Anhydrous Ammonia 1005. Emergency Preparedness. Information from the 2012 Emergency Response Guidebook ID # 1005 Guide # 125 Name of Material Anhydrous Ammonia. 1. Potential Hazards Health. TOXIC; may be fatal if inhaled, ingested or absorbed through skin

damita
Download Presentation

Anhydrous Ammonia 1005

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Anhydrous Ammonia 1005

  2. Emergency Preparedness • Information from the 2012 Emergency Response Guidebook • ID # 1005 • Guide # 125 • Name of Material Anhydrous Ammonia 1

  3. Potential HazardsHealth • TOXIC; may be fatal if inhaled, ingested or absorbed through skin • Vapors are extremely irritating and corrosive • Contact with gas or liquefied gas may cause burns, severe injury and/or frostbite • Fire will produce irritating, corrosive and/or toxic gases • Runoff from fire control may cause pollution 2

  4. Potential HazardsFire or Explosion • Some may burn but none ignite readily • Vapors from liquefied gas are initially heavier than air and spread along ground • Some of these materials may react violently with water • Cylinders exposed to fire may vent and release toxic and/or corrosive gas through pressure relief devices • Containers may explode when heated • Ruptured cylinders may rocket 3

  5. Public Safety • CALL EMERGENCY RESPONSE Telephone Number on Shipping Paper first. If Shipping Paper not available or no answer, refer to appropriate telephone number listed on the inside back cover of the 2012 Emergency Response Guidebook • As an immediate precautionary measure, isolate spill or leak area for at least 100 meters (330 feet) in all directions • Keep unauthorized personnel away • Stay upwind • Many gases are heavier than air and will spread along ground and collect in low or confined areas (sewers, basements, tanks) • Keep out of low areas • Ventilate closed spaces before entering 4

  6. Public SafetyProtective Clothing • Wear positive pressure self-contained breathing apparatus (SCBA) • Wear chemical protective clothing that is specifically recommended by the manufacturer. It may provide little or no thermal protection • Structural firefighters' protective clothing provides limited protection in fire situations ONLY; it is not effective in spill situations where direct contact with the substance is possible 5

  7. Public SafetyEvacuation Spill • See Table 1 - Initial Isolation and Protective Action Distances for highlighted materials. For nonhighlighted materials, increase, in the downwind direction, as necessary, the isolation distance shown under “PUBLIC SAFETY” Fire • If tank, rail car or tank truck is involved in a fire, ISOLATE for 1600 meters (1 mile) in all directions; also, consider initial evacuation for 1600 meters (1 mile) in all directions 6

  8. Emergency ResponseFire Small Fire • Dry chemical or CO2 Large Fire • Water spray, fog or regular foam • Move containers from fire area if you can do it without risk • Do not get water inside containers • Damaged cylinders should be handled only by specialists 7

  9. Emergency ResponseFire Fire involving Tanks • Fight fire from maximum distance or use unmanned hose holders or monitor nozzles • Cool containers with flooding quantities of water until well after fire is out • Do not direct water at source of leak or safety devices; icing may occur • Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank • ALWAYS stay away from tanks engulfed in fire 8

  10. Emergency ResponseSpill or Leak • Fully encapsulating, vapor protective clothing should be worn for spills and leaks with no fire • Do not touch or walk through spilled material. • Stop leak if you can do it without risk • If possible, turn leaking containers so that gas escapes rather than liquid • Prevent entry into waterways, sewers, basements or confined areas • Do not direct water at spill or source of leak • Use water spray to reduce vapors or divert vapor cloud drift. Avoid allowing water runoff to contact spilled material • Isolate area until gas has dispersed 9

  11. Emergency ResponseFirst Aid • Move victim to fresh air • Call 911 or emergency medical service • Give artificial respiration if victim is not breathing • Do not use mouth-to-mouth method if victim ingested or inhaled the substance; give artificial respiration with the aid of a pocket mask equipped with a one-way valve or other proper respiratory medical device. • Administer oxygen if breathing is difficult • Remove and isolate contaminated clothing and shoes • In case of contact with liquefied gas, thaw frosted parts with lukewarm water • • In case of contact with substance, immediately flush skin or eyes with running water for at least 20 • minutes 10

  12. Emergency ResponseFirst Aid • In case of contact with Hydrogen fluoride, anhydrous (UN1052), flush skin and eyes with water for 5 • minutes; then, for skin exposures rub on a calcium/gel combination; for eyes flush with a water/calcium solution for 15 minutes • Keep victim warm and quiet • Keep victim under observation • Effects of contact or inhalation may be delayed • Ensure that medical personnel are aware of the material(s) involved and take precautions to protect • themselves 11

  13. First Aid • In case of contact with Hydrogen fluoride, anhydrous (UN1052), flush skin and eyes with water for 5 • minutes; then, for skin exposures rub on a calcium/gel combination; for eyes flush with a water/calcium solution for 15 minutes • Keep victim warm and quiet • Keep victim under observation • Effects of contact or inhalation may be delayed • Ensure that medical personnel are aware of the material(s) involved and take precautions to protect • themselves 12

  14. Table 1 – referenced on page 6 INITIAL ISOLATION AND PROTECITVE ACTION DISTANCES SMALL SPILLS (From a small package or small leak from a large package) • FirstISOLATE in all directions • 30 Meters/100 Feet • ThenProtect persons downwind during • Day • 0.1 Kilometers/0.1 Miles • Night • 0.2 Kilometers/0.1 Miles 13

  15. Table 1 – referenced on page 6 INITIAL ISOLATION AND PROTECITVE ACTION DISTANCES LARGE SPILLS (From a large package or from many small packages) • First ISOLATE in all directions • 150 Meters/500 Feet • Then Protect persons downwind during • Day • 0.8 Kilometers/0.5 Miles • Night • 2.3 Kilometers/1.4 Miles 13