1 / 28

HEAT EXCHANGER NETWORK

HEAT EXCHANGER NETWORK. DIAGRAM GRID. CP (kW/C). 170 C. 60 C. 3,0. 2. 150 C. 30 C. 1,5. 135 C. 20 C. 2,0. 1. 4. 140 C. 80 C. 4,0. 3. PENJODOHAN ARUS. GUIDELINE. Di atas pinch : CP hot  CP cold Di bawah pinch : CP hot  CP cold. PENJODOHAN DI ATAS PINCH.

cyma
Download Presentation

HEAT EXCHANGER NETWORK

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. HEAT EXCHANGER NETWORK

  2. DIAGRAM GRID CP (kW/C) 170C 60C 3,0 2 150C 30C 1,5 135C 20C 2,0 1 4 140C 80C 4,0 3

  3. PENJODOHAN ARUS GUIDELINE • Di atas pinch : CPhotCPcold • Di bawah pinch : CPhotCPcold

  4. PENJODOHAN DI ATAS PINCH pinch CP (kW/C) 170C 90C 60C 2 3,0 150C 30C 90C 1,5 135C 20C 80C 1 2,0 4 140C 4,0 3 80C

  5. Penjodohanaliran yang melanggaraturan

  6. Jikaarus [2] dijodohkandenganarus [1]: Q1 = CP1 (135 – 80) = (2) (11) = 110 kW Q2 = CP2 (170 – 90) = (3) (80) = 240 kW Yang menjadipembatasadalaharus [1] dengankebutuhanpanas 110 kW. Jikasemuakebutuhanpanasarus [1] dipasokoleharus [2], makaperubahantemperaturarus [2] adalah: T = 110/CP2 = 110/3 = 36,7C Tin= 90 + 36,7 = 126,7C

  7. 126,7C 90C 135C 80C T = 10C T = 8,3C < Tmin

  8. Penjodohanaliran yang layak

  9. maksimalkanbebanpanasdalamsatuarus jumlah HE minimum

  10. pinch CP (kW/C) Q (kW) 170C 90C 3,0 240,0 2 150C 90C 1,5 90,0 4 135C 80C 1 2,0 110,0 140C 4,0 240,0 3 80C

  11. Arus [2] dijodohkandenganarus [3]: Q2 = 240 kW Q3 = 240 kW Arus [4] dijodohkandenganarus [1]: Q4 = 90 kW Q1 = 110 kW Sebagaipembatasadalaharus [4] Perubahantemperaturarus [1] dalam HE = 90/2 = 45C Temperaturarus [1] yang keluardari HE = 80 + 45 = 125C Arus [1] masihkekuranganpanassebesar 110 – 90 = 20 kW Panasiniharusdipasokolehutilitaspanas.

  12. pinch 170C 90C 2 150C 90C 80C 135C 125C H 1 4 20 kW 90 kW 80C 140C 3 240 kW

  13. PENJODOHAN DI BAWAH PINCH Arus-arusdinginharusdibawakeTpinchdengancaramempertukarkanpanasdenganarus-aruspanas. pinch CP (kW/C) Q (kW) 90C 60C 3,0 90,0 2 90C 30C 1,5 90,0 4 20C 80C 2,0 120,0 1

  14. Syarat: CPhot CPcold CP2 CP1  penjodohanlayak (3,0) (2,0) CP4 CP1  penjodohantidaklayak (1,5) (2,0)

  15. Arus [2] dijodohkandenganarus [1]: Q2 = 90 kW Q1 = 120 kW Sebagaipembatasadalaharus [2] Perubahantemperaturarus [1] dalam HE = 90/2 = 45C Temperaturarus [1] yang masukkeHE = 80 – 45 = 35C Arus [1] masihkekuranganpanassebesar 120 – 90 = 30 kW untukmemanaskanarus [1] dari 20C menjadi 35C

  16. Pemanasaninidipenuhidengancaramenjodohkanarus [1] denganaruspanas yang masihada, yaituarus [4]. Meskipunpenjodohanantaraarus [1] dan [4] tidakmemenuhikriteria CP, tetapipenjodohaninilayakkarenajauhdari pinch. Denganbebanpanassebesar 30 kW, makaarus 4 masihmemilikisisapanassebesar 60 kW yang harusdibuangkeutilitasdingineksternal.

  17. PEMECAHAN ARUS KRITERIA CP • Di atas pinch : CPhotCPcold • Di bawah pinch : CPhotCPcold KRITERIA JUMLAH ARUS • Di atas pinch : NhotNcold • Di bawah pinch : NhotNcold

More Related