1 / 12

Tests of the AC Dipole Based Nonlinear Optics in the Tevatron - Part 1

This article presents the conditions, procedures, and measurements of the AC Dipole based nonlinear optics tests conducted in the Tevatron. The measurements include beta-function and betatron phase measurements, as well as the detection of sources for higher order modes.

coreykent
Download Presentation

Tests of the AC Dipole Based Nonlinear Optics in the Tevatron - Part 1

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Tests of the AC Dipole BasedNonlinear Optics Measurementsin the Tevatron Part 1 Ryoichi Miyamoto Univ. of Texas at Austin 5/2/2008

  2. Conditions and Procedures of the Tests • The tests were done 2/20/2008 • Usual 150 GeV uncoalesced proton beam was used. • Large oscillations are produced with a vertical AC dipole at E17. • First, linear optics (βy and ψy) was measured. • For the detuning measurement, an octupole family (OD) was • changed from 0 and 13 A (the nominal is 7 A). Measurements were • made for several different AC dipole currents. • For the sextupole driving term measurement, an skew sextupole • (S2A3A) was set between −30 and 45 A (The nominal is ~0 A). • Measurements were made for several different AC dipole currents.

  3. Beta-Function Measurement (Not New) δd = νd−ν −0.04 −0.02 +0.02 0 • An AC dipole produces the • artificial beta-beat. • The true beta-function can be • extrapolated by sweeping the • driving frequency.

  4. Betatron Phase Measurement (New) δd = νd−ν −0.04 −0.03 −0.02 +0.01 +0.02 +0.04 0 • An AC dipole also produces the • artificial phase-beat. • The true betatron phase advance • can be also extrapolated by • sweeping the driving frequency. • The fit function is a bit more complex:

  5. Detuning νd<ν When the tune depends on the action, the amplitude of the driven motion is determined by the following two Eqs: νd>ν

  6. An Example of Nonlinear System Equation of Motion: HO with a Cubic Potential • Consider 1st order of k • Expansion: x = x0 + x1 +… • Leading order: 1st order: A sextupole 1. shifts the central orbit. 2. produces a higher order mode (2ν).

  7. Shifts of the Closed Orbit by a Sextupole • A skew sextupole is changed • from 0 [A] to −30 [A]. • The closed orbit changes • more for a larger kick. The phase of the orbit flips if the sign of the sextupole current is flipped.

  8. 1-νd νd 2νd 1-2νd 1-ν ν 1-3νd 3νd Higher Order Modes • Higher frequency modes appear for a larger oscillation. • The frequencies of the higher order modes change • with the driving frequency.

  9. w What do we measure? The closed orbit formula: Behavior of worW s If we know βandψ, from information of two BPM’s 1 and 2,we can construct

  10. Generating Function of the 1st Order Mode • A fixed sextupole current, different AC dipole current. • The strength of the sextupole is determined from the step size. • The kick strength depends on the action. • The action is not factored out, here

  11. Generating Function of the 3rd Order Mode • A similar analysis is possible for the 3rd order mode (Two same condition). • Two generating functions for resonances of 2νd−ν and 2νd+ν.

  12. One way to Detect Sources

More Related