MEGA Abrasive cutters (motor does not start). Symptom's Motor does not start Pump and light work Potential issues Safety switch in “UNLOCK” position Overload breaker tripped to “OFF” position 24V relay tripped. Safety Switch. Safety Switch.

cforrest
Download Presentation

MEGA Abrasive cutters (motor does not start)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. MEGA Abrasive cutters (motor does not start) • Symptom's • Motor does not start • Pump and light work • Potential issues • Safety switch in “UNLOCK” position • Overload breaker tripped to “OFF” position • 24V relay tripped

  2. Safety Switch

  3. Safety Switch • Safety switch is shipped in the “UNLOCK” position so that the hood can be opened without power. • When power is connected the motor WILL NOT turn on with safety switch in “UNLOCK” position • With power change switch to “LOCK” position with key provided

  4. Safety Switch To UNLOCK use key and turn clockwise

  5. Safety Switch In “LOCK” position for operation -Must be in this position for MOTOR to operate In “UNLOCK” position for shipping -MOTOR will not turn on

  6. Overload Switch • Overload switch will trip when too many amps are being pulled. • QF1 – motor switch • QF2 – pump switch • Oftentimes the switch can trip during transportation. Reset BLACK or ON button

  7. Overload Switch • MEGA-M250 • Open side electrical panel • Panel slides out on rails 24V relay switch Breaker overload switches

  8. Overload Switch • MEGA-T300 • Open front panel Breaker overload switches 24V relay switch

  9. Overload Switch • MEGA-T400 • Open side electrical panel Breaker overload switches 24V relay switch

  10. Overload Switch Black “ON” button engaged -Required for pump or motor to turn on Red “OFF” button engaged -Pump or motor will not turn on

  11. 24 Volt Relay • IF 24V relay is disengaged then motor and pump will not function • Reset by pressing red button on switch Press red button to reset