1 / 24

Single Diffractive Cross Section Calorimeter Gaps Approach Soft QCD Meeting 14 th Oct 2 0 10

Single Diffractive Cross Section Calorimeter Gaps Approach Soft QCD Meeting 14 th Oct 2 0 10. Tim Martin , Paul Newman University of Birmingham. Soft Diffraction. Diffractive Events Colour singlet exchange. Can be Single or Double proton dissociation .

Download Presentation

Single Diffractive Cross Section Calorimeter Gaps Approach Soft QCD Meeting 14 th Oct 2 0 10

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Single Diffractive Cross SectionCalorimeter Gaps ApproachSoft QCD Meeting14th Oct 2010 Tim Martin, Paul Newman University of Birmingham

  2. Soft Diffraction • Diffractive Events • Colour singlet exchange. • Can be Single or Double proton dissociation. • Diffractive mass can be anything from p+π0 up large systems with hundreds of GeV invariant mass. • Soft PTspectrum. • Large forward energy flow. • Less activity in the inner detector. Pythia Single Diff. Transverse Momentum Transfer

  3. Diffractive Mass Distributions • Measure dσ/dξover the ξ range accessible at ATLAS • Constrain the relative weights of SD, DD and ND At 7 TeV we should be getting really big diffractive systems! Pythia8

  4. Truth Level EnergyFlow • Normalised to a single event in ξ. • Differential in η. • Expect rapidity gap devoid of all soft activity. ηmax = η of Leading Truth Particle in X System Single Diffraction • Linear relation between η of leading particle and log(ξ), slope = 1 for ln(ξ). • Part hadronisation, mostly kinematics. Are there any MC diffractive models which do not use the lund string hadronisation model?

  5. Trigger Efficiency • Trigger events with the MBTS. Trigger is fully within calorimeter acceptance so use loose trigger requirement.L1_MBTS_2. Correct for trigger inefficiency in data using MC here `Here be dragons’ Unexploreable phase space with Calo + MBTS analysis.

  6. Experimental Re-definiton • In Double Diffraction, if the smaller system (MY) is too smallto get into the ATLAS calorimeters, then the event is experimentally indistinguishable (exc. ZDC) from a single diffractive event. This occurs around ξY of 10-6 New Definition: Double Diffractive Like Systematic Check: Location of cut Reclassify as Single Diffractive. Name the new sample Single Diffractive Like

  7. New Cross Sections • Singleand Double Diffractive Like take into account the migration of events from the Double Diffractive to Single Diffractive samples. • Visible refers to the subset of the samples which can be triggered with the MBTS.

  8. Samples & Calo Cells • Current data sample of ~750k, Pythia8, Phojet, Pythia6; ND, SD, DD • MC Empty • MinBias and RNDM stream for 1st 7 TeV run: • Run 152166 • ~600kL1_MBTS_2 & BCID = 1Events • 7719 mb. • Noise in TILEshow non-Gaussianprofile (double Gaussian). • TILE is not required for hermetic coverage of ATLAS and is currently excluded from the analysis. mc09_7TeV.105003.pythia_sdiff.recon.ESD.e514_s764_s767_r1307/ mc09_7TeV.105004.pythia_ddiff.recon.ESD.e514_s764_s767_r1307 mc09_7TeV.105001.pythia_minbias.recon.ESD.e517_s764_s767_r1307 data10_7TeV.00152166.physics_MinBias.recon.ESD.r1239/ data10_7TeV.00152166.physics_RNDM.recon.ESD.r1239/ mc09_7TeV.106096.PhojetNdiff.recon.ESD.e514_s764_s767_r1307 mc09_7TeV.106097.PhojetSdiff.recon.ESD.e514_s764_s767_r1307 mc09_7TeV.106098.PhojetDdiff.recon.ESD.e514_s764_s767_r1307 mc09_7TeV.108316.Pythia8_minbias_ND.recon.ESD.e533_s764_s767_r1307 mc09_7TeV.108317.Pythia8_minbias_SD.recon.ESD.e533_s764_s767_r1307 mc09_7TeV.108318.Pythia8_minbias_DD.recon.ESD.e533_s764_s767_r1307 Oldrich & Pavel EM Barrel

  9. EM Endcap Inner EM Barrel CaloCellSignificance EM Endcap Outer Data10 MBTS_2 Data10 RD0_EMPTY MC Py8 Inelastic MC Empty Tile Very Bad FCAL HEC

  10. Cell Requirement • Using an Energy Veto • Currently require 1 cell above 5.5 E/σ. • Can perhaps improve our sensitivity by combining cells? • No good for all cells in a slice. • E.G Barrel slice: 39,925 cells • RMS Noise of all cells combined: 8.6 GeV! • Swamps any minimum bias energy deposition. • However, combination of cells with E/σ > 3 looks more promising. • Order 50 cells per η slice, RMS noise of ~100 MeV– manageable. Under current investigation, may improve systematics.

  11. Being Quantified Gap Finding • •Trigger on L1_MBTS_2. • •Negligiblepileup, no prescales, low beam backgrounds. • •Divide the calorimeter into 10x rings spanning 1 unit of η. • •Ring is full if 1 or more calo cells satisfy E/σCell > Threshold • •Look for largest continuous gap of empty rings. • •Plot Start of Gap [|η|] vs. Size of Gap [Δη]. • •The start of the gap is defined as the |η| of it’s farthest edge from η=0 • •Provides separation of diffractive and non-diffractive. Systematic Check E.G. Single Diffractive Event MX Largest η Gap MBTS MY η

  12. Overall Trigger Efficiency MC • Trigger efficiency calculated from MCon a bin-by-bin basis. • Fractional breakdown of event types in each bin displayed below. Overall Trigger Eff. Totally Empty Detector Bin Totally Full Detector Bin Bin-by-bin Breakdown of Event types Key

  13. Tr. Eff Correction • Trigger efficiency corrections are applied bin-by-bin to the data histogram. • Bins with a MCtrigger efficiency of < 50 % are not used in the fit. • These are the `here be dragons bins’ Low Efficiency Before Correction After Correction

  14. Formation of MC Templates ND SD DD • Map 2D distribution onto 1D plot for the purpose of fitting. • Pre-trigger MC distributions. • Normalise each MC shape to a single event. • Bins with overall trigger efficiency < 50% are plotted last – beyond the black line. • These bins are not included in the fit.

  15. Check of Fit 1000 Trials One Trial • Form pseudo-data by applying bin-by-bin Poisson smear to MC prediction. • Fit relative SD, DD and ND templates to pseudo-data. • Fit constrained to sum to 1 Residuals for one trial

  16. Fit to Data – Pythia8 Pythia8: ND: 73.6% SD Like: 23.7% DD Like: 2.7% Fit: ND: 74.2% SD Like: 18.1% DD Like: 7.74% • Fit to data normalization in fitted bins. • Log likelihood fit. • MC shapes do not fully describe the data. Poor χ2

  17. Detector Acceptance • To convert to a cross-section, need to correct back to the particle level. • Run gapfinding algorithm over truth level data. • Move from Calo Cells  Truth Particles • Move from E/σ cut  PT cut • Build bin-by-bin correction histogram to apply to data. • c.f the trigger efficiency correction. Correction factors manageable in Single Diffractive Like (edge gap) region. Large correction factors in Double Diffractive Like region (central gaps)

  18. Single-Diffractive • Comparison of algorithms at: • Truth (PT > 200 MeV) • Reco (E/σ > 5.5) • Hatched boxes denote located gaps. • Correct effects such as: • Low PT particles not reaching callo. • Multiple scattering.

  19. Cross Section Last two bins have Trigger Efficiency < 50% • This slide 0 MeV PTcut gap definition • Data is... • Corrected for Trigger Efficiency & for Detector Acceptance. • Scaled to Lumi of run. • Plotted systematics, `best and worse case scenarios’ • E/σ > 5 noiseAND +10% Cell energy scale AND 111% Lumi. • E/σ > 6 noise AND -10% Cell energy scale AND 89% Lumi. Suggestion from R. Barlow! Will check adding in quad as well. Default & fitted fractional visible Xsec MC lines Statistical error negligible Systematic Band (systematics invert)

  20. Cross Section • This slide 100 MeV PTcut gap definition • Interesting sensitivity to choice of PTcut defining cross section. • Most effect at small gaps, explained as increasing pollution from non-diffractive events. • Flick back and forth...

  21. Cross Section • This slide 200 MeV PT cut gap definition • Flick back and forth...

  22. Cross Section • This slide 500 MeV PT cut gap definition • Flick back and forth... Work ongoing to match a sensible PT cut with the E/σ cut. No particles in the gap (PT > 0 cut) looks sensible. Can also publish differential in PT

  23. Cross Section • Combination into a single result. • Pythia8taken as trigger and acceptance correction MC • Maximum deviation per data point for Pythia6 and Phojet taken as systematic. • Added in quad., last two (low trigg. Eff.) bins not plotted. 0 MeV PT Definition 100 MeV PT Definition

  24. Conclusion • Single diffractive like cross section dσ/dη = 1 mbη-1 • Measurement of the single diffractive like cross section at 7 TeV possible with very little minimum bias data. • Many cross checks, systematic checks, systematic quantification is underway. • Still a bit more work to do with Calo Cell selection & PT dependence on acceptancecorrection. • We are working to compare with Tevatronresults at 2 TeV. • We are writing, detailed internal note for the analysis being produced atthe moment. • Details theory, all steps & cross checks.

More Related