1 / 5

Manufactured Home Weatherization Measures

This document outlines the proposal to change the status of Manufactured Home Weatherization UES Measures to "active" during the Regional Technical Forum meeting on February 14, 2011. Following a review of comments from RTF members regarding savings discrepancies and heat pump calibration issues, changes have been made to the measure analysis provided in the Measure Workbook. Key discussions included the applicability of prime window replacements and adjustments to infiltration reduction measurements. The proposal aims for a five-year sunset date for the measures.

aysel
Download Presentation

Manufactured Home Weatherization Measures

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Manufactured Home Weatherization Measures Proposal to Change UES Measure Status to Active 2nd Attempt Adam Hadley Regional Technical Forum February 14th, 2011

  2. Background • Background • At January 17, 2012 RTF meeting • Changes to Manufactured Home Weatherization UES Measures presented • RTF members requested time to review the measure analysis for errors • Measure Workbook • SEEM Runs • Status changed from “out-of-compliance” to “under review” • Today • We’ll review the comments received and changes made • Note: The voluntary detailed review of the input assumptions and analysis within the workbooks was not performed. • Decide on proposal to change status to “active”

  3. Comments Received & Response • Erin Hope • Comment: Concern with difference in savings between SEEM92 and SEEM 94. Why difference in % savings between heat pumps and FAF’s? • Response: Adam and Erin reviewed reasons for change in savings (different changes in t-stat settings between HP’s and FAF’s, along with change to infiltration modeling w/SEEM94). Compared example SEEM92 and SEEM94 runs. • Comment: Concern with calibration for heat pumps. • Response: Agreement that collecting more data on heat pumps in manufactured homes to refine calibration is not a high priority.

  4. Comments Received & Response • Mark Johnson • Comment: Question on applicability of prime window replacements, U-Factor Upgrades Measures (“Class 35 to Class 30” and “Class 35 to Class 22”). Can this measure be used for glass only replacements or for window replacements where the existing window is better than a double-glazed metal framed window? • Response: Measure could apply any time a new NFRC-rated window is being installed (as long as another measure isn’t also installed). • Comment: Change infiltration reduction UES measure to “per CFM50” rather than per 100 CFM50” • Response: Agree – made change in revised workbook (ResMHWx_v3_1.xlsm) • Comment: Make it clear whether “average” and heating-system-specific measures can be combined within programs. • Response: Agree – made change in revised workbook (Delivery Mechanism or Program field) stating the two measure types are not allowed to be mixed within a program (must choose one or the other).

  5. Motion to Adopt “I _________ move that the RTF approve the Manufactured Home Weatherization UES Measure under active status with a sunset date of 5 years.”

More Related