NORMAS BASICAS. TIPOS DE LAMPARAS MAS UTILIZADOS EN ALUMBRADO DE EXTERIORES. HALOGENUROS METALICOS. VAPOR DE MERCURIO. VIDA MEDIA (0-5) = 1 EFICIENCIA ENERGETICA(0-5) = 3 IMPACTO EN ASTRON0M IA(0-5) = 5 REPRODUCCION CROMAT. (0-5) = 5. VIDA MEDIA (0-5) = 3 EFICIENCIA ENERGETICA(0-5) = 2

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about 'NORMAS BASICAS' - audi


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
tipos de lamparas mas utilizados en alumbrado de exteriores
TIPOS DE LAMPARAS MAS UTILIZADOS EN ALUMBRADO DE EXTERIORES

HALOGENUROS METALICOS

VAPOR DE MERCURIO

VIDA MEDIA (0-5) = 1

EFICIENCIA ENERGETICA(0-5) = 3

IMPACTO EN ASTRON0M IA(0-5) = 5

REPRODUCCION CROMAT. (0-5) = 5

VIDA MEDIA (0-5) = 3

EFICIENCIA ENERGETICA(0-5) = 2

IMPACTO EN ASTRON0M IA(0-5) = 4

REPRODUCCION CROMAT. (0-5) = 3

VAPOR DE SODIO DE ALTA PRESION

VAPOR DE SODIO DE BAJA PRESION

VIDA MEDIA (0-5) = 3

EFICIENCIA ENERGETICA(0-5) = 5

IMPACTO EN ASTRON0M IA(0-5) = 1

REPRODUCCION CROMAT. (0-5) = 0

VIDA MEDIA (0-5) = 3

EFICIENCIA ENERGETICA(0-5) = 4

IMPACTO EN ASTRON0M IA(0-5) = 3

REPRODUCCION CROMAT. (0-5) = 2

adaptacion aeropuerto de los rodeos
ADAPTACION AEROPUERTO DE LOS RODEOS

ANTES

INSTALACION:

42 PROYECTORES CON LAMPARA DE 2000 W DE H.M.

LUMENES INSTALADOS: 7.560 Klúmenes.

WATIOS INSTALADOS: 84.000 W

ENERGIA ANUAL: 367.920 Kw.h/año ---- 33.169 €/año

LAMPARA DE H.M..------ DURACION APROX.: 1 AÑO.

COSTE ANUAL REPOSICION APROX.: 12.621 €

DESPUES

INSTALACION:

40 PROYECTORES CON LAMPARA DE 750 W DE V.S.A.P.

LUMENES INSTALADOS: 4.400 Klúmenes.

WATIOS INSTALADOS: 30.000 W

Con reduccion a las 11:00 h: 40 x 340 W= 13.600 W

ENERGIA ANUAL: 80.000 Kw.h/año ---- 7.212 €/año

LAMPARA DE V.S.A.P.------ DURACION APROX.: 4 AÑOS.

COSTE ANUAL REPOSICION APROX.: 1.202 €

adaptacion aeropuerto de los rodeos1

RESUMEN ANTES-DESPUES

ADAPTACION AEROPUERTO DE LOS RODEOS

LUMENES INSTALADOS: - 42 %

POTENCIA INSTALADA: - 64 %

ENERGIA CONSUMIDA: - 78 %

AHORRO AL AÑO ENERGIA APROX: 25.957 €

AHORRO REPOSICION/ AÑO APROX: 11.419 €

AHORRO TOTAL: 37.376 €

COSTE DE ADAPTACION INFERIOR A 36.061 €

MEJORA DE LA UNIFORMIDAD CON NIVELES DE ILUMINACION SIMILARES

adaptacion de la plaza de europa
ADAPTACION DE LA PLAZA DE EUROPA

ANTES

INSTALACION:

44 LUMINARIAS CON LAMPARA DE 125 W DE V.M.

LUMENES INSTALADOS: 286 Klúmenes.

WATIOS INSTALADOS: 6.028 W

ENERGIA ANUAL: 26.280 Kw.h/año ---- 2.369 €/año

DESPUES

INSTALACION:

44 LUMINARIAS CON LAMPARA DE 100 W DE V.S.A.P.

Y APAGADO 3/4 DESPUES DE LAS 24:00 h.

LUMENES INSTALADOS: 418 Klúmenes.

WATIOS INSTALADOS: 5.060 W

ENERGIA ANUAL: 11.081 Kw.h/año ---- 999 €/año

adaptacion de la avda maritima

ANTES

ADAPTACION DE LA AVDA. MARITIMA

LAMPARA: 250W V.S.A.P (275W)

FLUJO: 24750 LUMEN

EFICACIA LUMINARIA: 75%

FLUJO HACIA ARRIBA: 6%

FLUJO HACIA ABAJO : 94%

NUMERO DE UNIDADES: 48

FLUJO ABAJO: 837.540 LUMEN

FLUJO ARRIBA (+10% REFLEXION): 137.214 LUMEN

CONSUMO ANUAL: 275 x 12 x 365 x 48 = 57.816 KW

COSTE ANUAL ENERGIA A 0.09 €/KWh: 5.212 €/AÑO

DESPUES

LAMPARA: 250W V.S.A.P ANTES 24h ---- 90W V.S.B.P. DESPUES 24h

FLUJO: 250W 24750 LUMEN ---- 90W 13500 LUMEN

EFICACIA LUMINARIA: 250 W 70% ---- 90 W 58%

FLUJO HACIA ARRIBA: 0%

FLUJO HACIA ABAJO : 100%

NUMERO DE UNIDADES: 48

FLUJO ABAJO: ANTES 24h 831.600 LUMEN / DESPUES 24h 375.840 LUMEN

FLUJO ARRIBA (+10% REFLEXION): ANTES 24h 83.160 LUMEN / DESPUES 24h 37.584 LUMEN

CONSUMO ANUAL: (275 x 4 +113 x 8) x 365 x 48 = 35.110 KW

COSTE ANUAL ENERGIA A 0.09 €/Kwh: 3.165 €/AÑO

adaptacion en barlovento

ANTES

DESPUES

ADAPTACION EN BARLOVENTO

LAMPARA: V.S.B.P. 35W

FLUJO: 4800 LUMEN

EFICACIA: 50%

FLUJO HACIA ARRIBA: 0.1%

FLUJO HACIA ABAJO: 99.9%

UNIDADES: 130

LAMPARA: V.S.B.P. 35W

FLUJO: 4800 LUMEN

EFICACIA: 67%

FLUJO HACIA ARRIBA: 0%

FLUJO HACIA ABAJO: 100%

UNIDADES: 68

LAMPARA: V.S.A.P. 100W

FLUJO: 8550 LUMEN

EFICACIA: 50%

FLUJO HACIA ARRIBA : 35%

FLUJO HACIA ABAJO: 65%

UNIDADES: 198

adaptacion en barlovento1
ADAPTACION EN BARLOVENTO

PLAZA DE BARLOVENTO ANTES

CALLE DE BARLOVENTO ANTES

PLAZA DE BARLOVENTO DESPUES

CALLE DE BARLOVENTO DESPUES

adaptacion en barlovento2

1992

1994

ADAPTACION EN BARLOVENTO

SIMULACION

CONCLUSIONES

TOTAL REDUCCION FLUJO HACIA ARRIBA(CONTAMINACION) : 84.8%

TOTAL REDUCCION FLUJO HACIA ABAJO (ILUMINACION): 3.6%TOTALREDUCCION CONSUMO ENERGETICO (AHORRO): 65%