1 / 31

MARE

MARE. M icrocalorimeter A rrays for a R henium E xperiment. A DETECTOR OVERVIEW. Andrea Giuliani , University of Insubria, Como, and INFN Milano on behalf of the MARE collaboration. Outline of the talk. The physics case: importance of direct m n measurement

asabi
Download Presentation

MARE

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. MARE Microcalorimeter Arrays for a Rhenium Experiment A DETECTOR OVERVIEW Andrea Giuliani, University of Insubria, Como, and INFN Milano on behalf of the MARE collaboration

  2. Outline of the talk • The physics case: importance of direct mn measurement • Methods: spectrometers and microcalorimeters • Status of microcalorimeters and prospects • MARE-1: techniques, detectors and sensitivity • MARE-2: new detector technologies • Conclusions

  3. Outline of the talk • The physics case: importance of direct mn measurement • Methods: spectrometers and microcalorimeters • Status of microcalorimeters and prospects • MARE-1: techniques, detectors and sensitivity • MARE-2: new detector technologies • Conclusions

  4. Tools for the investigation of the n mass scale Future sensitivity (a few year scale) Present sensitivity Tools Cosmology (CMB + LSS) 0.7 - 1 eV 0.1 eV Neutrinoless Double Beta Decay 0.5 eV 0.05 eV Single Beta Decay 2.2 eV 0.2 eV Model dependent Direct determination Laboratory measurements Neutrino oscillations cannot provide information about a crucial parameter in neutrino physics: the absolute neutrino mass scale

  5. The modified part of the beta spectrum is over range of the order of [Q – Mnc2 , Q] The count fraction laying in this range is  (Mn/Q)3 low Q are preferred Tritium as an example E – Q [eV] Effects of a finite neutrino mass on the beta decay

  6. Outline of the talk • The physics case: importance of direct mn measurement • Methods: spectrometers and microcalorimeters • Status of microcalorimeters and prospects • MARE-1: techniques, detectors and sensitivity • MARE-2: new detector technologies • Conclusions

  7. Electron analyzer Electron counter Source n T2 b excitation energies electron high activity • high efficiency • low background • high energy resolution • integral spectrum: select Ee > Eth spectrometers MAINZ-TROITZK 2.2 eV - KATRIN (2010)  0.2 eV microcalorimeters MIBETA  15.0 eV • high energy resolution • differential spectrum: dN/dE bolometer When in presence of decays to excited states, the calorimeter measures both the electron and the de-excitation energy

  8. Calorimetry: pros and cons pure b spectrum pile-up spectrum energy [eV] energy region relevant for neutrino mass DE • Drawback • background and systematics induced by pile-up effects • Advantages • no backscattering • no energy loss in the source • no excited final state problem • no solid state excitation (dN/dE)exp=[(dN/dE)theo+ Atr(dN/dE)theo(dN/dE)theo]  R(E) generates “background” at the end-point

  9. Calorimeter requirements A sensitive measurement with the calorimetric method requires: • precise determination of the b energy • high statistics • low pile-up fraction • short pulse-pair resolving time • fractionate the whole detector in many independent elements bound on mn 1 / (Ncounts)1/4 bound on mn (DE)1/2 In terms of detector technology: development of a single element with these features • extremely high energy resolution in the keV range (1 ‰) • very fast risetime (100 ms 1 ms) • high reproducibility of the single element • possibility of multiplexing

  10. Outline of the talk • The physics case: importance of direct mn measurement • Methods: spectrometers and microcalorimeters • Status of microcalorimeters and prospects • MARE-1: techniques, detectors and sensitivity • MARE-2: new detector technologies • Conclusions

  11. Microcalorimeters for 187Re spectroscopy • Calorimeters measure the entire spectrum at once • use low Q beta decaying isotopes to achieve enough statistic close to Q • best choice: 187Re – Q = 2.47 keV - 1 mg natural Re  1 Bq vs. 3x10-10 for T beta spectrum event fraction in the last 10 eV: 1.3x10-7 5/2+ 1/2– unique first forbidden (computable S(Ee)) 187Re 187Os + e- + ne General structure of a microcalorimeter Re crystal coupling coupling heat sink ~ 100 mK sensor a proper sensor convert excitation number to an electrical signal • beta decays produce very low • energy (~ meV) excitations • phonons • quasiparticles a dilution refrigerator provides the necessary low temperatures

  12. True microcalorimeters beta decay thermal phonons transmission to a phonon sensor (thermometer) semiconductor thermistor transition edge sensor (TES) R R MW mW W T T 100 mK 100 mK

  13. MANU (Genoa) MIBETA (Milano/Como) 1 mm 1 mm Energy absorbers • AgReO4 single crystals • 187Re activity  0.54 Hz/mg • M  0.25 mg  A  0.13 Hz Phonon sensors • Si-implanted thermistors • high reproducibility  array • possibility of m-machining • Energy absorber • Metalllic Re single crystals • M  1.5 mg  A  1.5 Hz • Phonon sensor • NTD Ge thermistors • size = 0.1 x 0.1 x 0.23 mm typically, array of 10 detectors lower pile up & higher statistics total collected statistics ~ 365 mg  day 6.2 x 106 decays above 700 eV single crystal total collected statistics: 6. x 106 decays above 420 eV Precursors 187Re experiments

  14. MIBETA MANU Kurie plot beta spectrum Q = 2466.1 0.8 stat  1.5 syseV Q = 2470 1 stat  4 syseV t½ = 43.2 0.2 stat  0.1 sysGy t½ = 41.2  0.02 stat  0.11 sysGy Mb2 = -141  211 stat  90 sys eV2 Mb2 = - 462 + 579 - 679 eV2 Mb< 15 eV (90% c.l.) Mb< 26 eV (95% c.l.)

  15. The future of bolometric experiments: MARE MARE is divided in two phases MARE-2 MARE-1 transition edge sensors (TES) (Ge) semiconductor thermistors (Mi/Co) and TES or magnetic calorimeters or kinetic inductance detectors ~ 50000 elements ~ 300 elements Activity/element ~ 0.25 Hz Activity/element ~ 1-10 Hz TR ~ 100 - 500 ms TR ~ 1 - 10 ms DEFWHM ~ 20 eV DEFWHM ~ 5 eV 0.2 eV mn sensitivity 2-4 eV mn sensitivity • General strategy: push up bolometric technology aiming at: • multiplication of number of channels • improvement of energy resolution • decrease of pulse-pair resolving time

  16. The collaboration Genova NASA Heidelberg Como Milano NIST Boulder ITC-irst PTB Berlin Roma SISSA Wisconsin

  17. Outline of the talk • The physics case: importance of direct mn measurement • Methods: spectrometers and microcalorimeters • Status of microcalorimeters and prospects • MARE-1: techniques, detectors and sensitivity • MARE-2: new detector technologies • Conclusions

  18. Required total statistics (MARE-1) On the basis of the analytical approach to pile-up problem and on preliminary Monte Carlo studies, the sensitivity as a function of the total statistics can be determined, for assumed detector performance in terms of time/energy resolution target statistics

  19. MARE-1 / semiconductor thermistors(Milano / Como) Three options in parallel, in all cases micromachined arrays: Si doped thermistors realized by NASA/Wisconsin collaboration Si doped thermistors realized by irst-ITC, Trento NTD Ge thermistors (LBL, Berkeley) on Si3N4 membranes single pixel 0.3  0.3 mm AgReO4 crystals 36 elements

  20. MARE-1 / semiconductor - single pixel performance Best energy resolution: 19 eV FWHM @ 1.5 keV Fastest risetime: 230 ms (10%-90%) Calibration spectrum obtained at 85 mK M = 0.4 mg Re spectrum Very promising for MARE-1 development

  21. MARE-1 / semiconductor - prospects ~ 400 ms time resolution  ~ 50 ms time resolution 288 elements gradually deployed 0.3 decays/s/element

  22. MARE-1 / transition edge sensors(Genoa) Tc lowered by proximity effect • Two searches are going on in parallel • Ag-Al superconductive hcp d-phase alloy • Ir-Au film Ir\Au\Ir multilayer on Si Resist pattern Ar Ion etching Final result Re crystals

  23. MARE-1 / TES - single pixel performance Energy resolution 11 eV FWHM @ 5.9 keV risetime: 160 ms In a few years, the present limit on neutrino mass (2.2 eV) can be approached

  24. Outline of the talk • The physics case: importance of direct mn measurement • Methods: spectrometers and microcalorimeters • Status of microcalorimeters and prospects • MARE-1: techniques, detectors and sensitivity • MARE-2: new detector technologies • Conclusions

  25. Required total statistics (MARE-2) groups involved in detector developments for future X-ray mission are working for us! tR 1 ms guideline for R&D on single pixel: goals DEFWHM  5 eV multiplexing scheme 10000 element array “kit” guideline for R&D on set-up: goals development of several “kits” target statistics

  26. Candidate techniques for MARE-2 MMC TES NASA-GSFC, Wisconsin, NIST Boulder Kirkhoff Institute of Physics, Heidelberg 450 mm Bi absorber 250 mm Magnetic MicroCalorimeter Mo/Cu TES Si3N4 membrane 55Mn 3.4 eV FWHM

  27. A superconductive strip below the critical temperature has a surface inductance proportional to the penetration depth l ( ~ 50 nm) of an external magnetic field Ls= m0l Zs = Rs + iwLs The impedance is Absorption of quasiparticles changes both Rs and Ls If the strip is part of a resonant circuit, both width and frequency of the resonance are abruptly changed phase variation signal New available technology MKID Multiplexed kinetic inductance detectors Roma, ITC-irst, Cardiff

  28. MKIDs: results Nature, K. Day et al., 2003 Resonance peak Aluminum strip on a Si substrate Equivalent circuit phase signal induced by absorption of a single 5.9 keV photon metallurgic problem: coupling of the Re crystal to the Al film

  29. MARE: statistical sensitivity 10000 detectors deployed per year 50000 channels in 5 y

  30. Outline of the talk • The physics case: importance of direct mn measurement • Methods: spectrometers and microcalorimeters • Status of microcalorimeters and prospects • MARE-1: techniques, detectors and sensitivity • MARE-2: new detector technologies • Conclusions

  31. Neutrino is at the frontier of particle physics Its properties have strong relevance in cosmology and astrophysics • Absolute mass scale, a crucial parameter, is not accessible via flavor oscillations • Direct measurement through single beta decay is the only genuine model independent method to investigate the neutrino mass scale • KATRIN is the only funded next generation experiment (0.2 eV) • Low temperature microcalorimeters can provide an alternate path to the sub-eV region • Microcalorimeters will develop in two phases: MARE-1 - technology already established - 2 eV in 5 y scale MARE-2 - new technologies are required - 0.2 eV in 10 y scale • Unlike spectrometers, microcalorimeter technology can be expanded further

More Related