1 / 9

Current pulse in the graphite wire

Goran Skoro . Current pulse in the graphite wire. LS-DYNA simulations. Graphite. Initial temperature = 500 C. Geometry. 3 cm long wire. Radius [mm]: 0.3, 0.5, 0.75, 1, 1.5. Loads. Current pulse length: 800 ns. Current pulse length: 400 ns (same shape). strain.

anoki
Download Presentation

Current pulse in the graphite wire

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Goran Skoro Current pulse in the graphite wire

  2. LS-DYNA simulations Graphite Initial temperature = 500 C Geometry • 3 cm long wire • Radius [mm]: 0.3, 0.5, 0.75, 1, 1.5 Loads • Current pulse length: 800 ns • Current pulse length: 400 ns (same shape) strain • Energy density -> temperature rise; • Lorenz force induced pressure wave.

  3. In the graphite wire case, Lorenz force plays equally important role as thermal stress Stress in the T2K target 0.3 mm radius wire; 800 ns long pulse 0.3 mm radius wire; 400 ns long pulse 0.5 mm radius wire; 800 ns long pulse Peak current [A] Results Peak von Mises stress [MPa] Stress as a function of the peak current in the graphite wire (operating at 500 C) LS-DYNA

  4. 0.5 mm radius Results Von Mises Stress LS-DYNA

  5. 0.5 mm radius Results Radial velocity LS-DYNA

  6. Peak current [A] Stress in the T2K target 0.75 0.3 0.5 1.5 1 Results Peak von Mises stress [MPa] Stress as a function of the peak current and the graphite wire radius [in mm] fixed pulse length = 800 ns LS-DYNA

  7. Peak current [A] T2K (0.75 MW) T2K (4 MW) T2K (2 MW) 0.75 0.5 0.3 1.5 1 Results Peak von Mises stress [MPa] Stress as a function of the peak current and the graphite wire radius [in mm] fixed pulse length = 800 ns LS-DYNA * * * Stress is calculated in the 3cm diameter, 90cm long graphite target.

  8. Peak current [A] T2K (2 MW) T2K (4 MW) T2K 0.75 0.5 0.3 1.5 1 Results T [K] Temperature rise per pulse as a function of the peak current and the graphite wire radius [in mm] fixed pulse length = 800 ns LS-DYNA T is calculated using the radial current penetration/time formula

  9. Peak current [A] T2K (2 MW) T2K (4 MW) T2K 0.75 0.5 0.3 1.5 1 Results T [K] Temperature rise per pulse as a function of the peak current and the graphite wire radius [in mm] fixed pulse length = 800 ns LS-DYNA T is calculated using the radial current penetration/time formula

More Related