SkyTEM -nuværende muligheder -fremtidige udviklinger. Outline. Krav til og verifikation af SkyTEM udviklingen i 2002 SkyTEM system 2009 Udvalgte tekniske SkyTEM detaljer SkyTEM –fremtidige udviklinger. Basics physics of TEM. How does it work?
E N D
Outline • Krav til og verifikation af SkyTEM udviklingen i 2002 • SkyTEM system 2009 • Udvalgte tekniske SkyTEM detaljer • SkyTEM –fremtidige udviklinger
Basics physics of TEM How does it work? A stationary current flows in the transmitter loop -which sets up a primary magnetic field The current is shut off abruptly -which induces currents in the subsurface. This generates a secondary magnetic field -which is measured in the receiver coil at the surface Primary field Secondary field Current flow I
Basic instrumentation of TEM Sender spole(r) Sender Rx Central Loop Tx Rx SkyTEM Loop Reference Rx Rx Offset Loop Modtager
Krav til SkyTEM system (-Danmark.2002) • 1D lagdelte strukturer • Should meet data quality of groundbased TEM methods • Should reproduce ground based TEM results (refence site) • No bias correction nor leveling of data sets • Accurate geometrical parameters for inversion • Rawdata (“coil data”) available • Easy operation for “small” areas with fast mob/demob
Krav til SkyTEM system (-Danmark.2002) • 1D lagdelte strukturer • Samme eller bedre datakvalitet som jordbaserede TEM data • Should reproduce ground based TEM results (refence site) • No bias correction nor leveling of data sets • Accurate geometrical parameters for inversion • Rawdata (“coil data”) available • Easy operation for “small” areas with fast mob/demob
Krav til SkyTEM system (-Danmark.2002) • 1D lagdelte strukturer • Samme eller bedre datakvalitet som jordbaserede TEM data • Reproducere jordbaserede TEM data (reference lokalitet) • No bias correction nor leveling of data sets • Accurate geometrical parameters for inversion • Rawdata (“coil data”) available • Easy operation for “small” areas with fast mob/demob
Krav til SkyTEM system (-Danmark.2002) • 1D lagdelte strukturer • Samme eller bedre datakvalitet som jordbaserede TEM data • Reproducere jordbaserede TEM data (reference lokalitet) • Ingen bias eller drift korrektion af data • Accurate geometrical parameters for inversion • Rawdata (“coil data”) available • Easy operation for “small” areas with fast mob/demob
Krav til SkyTEM system (-Danmark.2002) • 1D lagdelte strukturer • Samme eller bedre datakvalitet som jordbaserede TEM data • Reproducere jordbaserede TEM data (reference lokalitet) • Ingen bias eller drift korrektion af data • Nøjagtige geometriske parametre og system respons til inversionen • Rawdata (“coil data”) available • Easy operation for “small” areas with fast mob/demob
Krav til SkyTEM system (-Danmark.2002) • 1D lagdelte strukturer • Samme eller bedre datakvalitet som jordbaserede TEM data • Reproducere jordbaserede TEM data (reference lokalitet) • Ingen bias eller drift korrektion af data • Nøjagtige geometriske parametre og system respons til inversionen • Rådata til rådighed for kvalitetskontrol • Easy operation for “small” areas with fast mob/demob
Krav til SkyTEM system (-Danmark.2002) • 1D lagdelte strukturer • Samme eller bedre datakvalitet som jordbaserede TEM data • Reproducere jordbaserede TEM data (reference lokalitet) • Ingen bias eller drift korrektion af data • Nøjagtige geometriske parametre og system respons til inversionen • Rådata til rådighed for kvalitetskontrol • Operation mulig for “små” arealer med hurtig mob/demob
Senderen SkyTEM December 2002
Verifikation af SkyTEM system • reference målinger med ProTEM47 i en 40x40m Central loop • reference model fra inversion af reference målinger • udregne “SkyTEM reference målinger” i operationshøjder • reproducere “SkyTEM reference målinger” med SkyTEM system i operationshøjder • checke bias i stor højde
Verifikation af SkyTEM system • reference measurements with ProTEM47 in a 40x40m Central loop • reference model from inversion of reference measurements • calculate “SkyTEM reference measurements” for operation altitudes • reproducere “SkyTEM reference målinger” med SkyTEM system i operationshøjder • documentation of no significant bias signal at high altitudes
Low Tx signal (5.000 Am2, 6 ms) Verification of SkyTEM 2002 High Tx signal (30.000 Am2, 80 ms) SkyTEM Altitude 10 m Reference data set (calculated)
Verification of SkyTEM 2002 SkyTEM Altitude 10 m R: Measured data set B: Reference data set Error bars: B: 2% R: 3%
Verification of SkyTEM 2002 SkyTEM Altitude 20 m Reference data set (calculated)
Verification of SkyTEM 2002 SkyTEM Altitude 20 m R: Measured data set B: Reference data set Error bars: B: 2% R: 3%
Verification of SkyTEM 2002 SkyTEM Altitude 30 m Reference data set (calculated)
Verification of SkyTEM 2002 SkyTEM Altitude 30 m R: Measured data set B: Reference data set Error bars: B: 2% R: 3%
Verifikation af SkyTEM system • reference measurements with ProTEM47 in a 40x40m Central loop • reference model from inversion of reference measurements • calculate “SkyTEM reference measurements” for operation altitudes • reproduce reference measurements with SkyTEM instrumentation in a40x40m Central loop on ground • checke bias i stor højde
Verifikation af SkyTEM system Data fra stor højde skal indikere • ubetydelige lækage strømme • ubetydelig Tx – Rx interaktion • ubetydelig induktion af hvirvelstrømme i helikopter
1e-04 1e-05 1e-06 1e-07 dB/dt [V/(m^2*s)] 1e-08 SITEM Version: 1.2.4.55 Date: 18-02-2004 Time: 15:23:15 1e-09 1e-10 1e-05 1e-04 1e-03 Time [s] Verification of SkyTEM 2002 Noise signal 600 m SkyTEM Bias measurements High Altitude 600 m
1e-04 1e-05 1e-06 1e-07 dB/dt [V/(m^2*s)] 1e-08 SITEM Version: 1.2.4.55 Date: 18-02-2004 Time: 15:28:45 1e-09 1e-10 1e-05 1e-04 1e-03 Time [s] No measurements of decay signal Verification of SkyTEM 2002 Decay signal 600 m Noise signal 600 m SkyTEM Bias measurements High Altitude 600 m High Tx moment only
1e-04 1e-05 1e-06 1e-07 dB/dt [V/(m^2*s)] 1e-08 SITEM Version: 1.2.4.55 Date: 18-02-2004 Time: 15:32:43 1e-09 1e-10 1e-05 1e-04 1e-03 Time [s] Decay signal operating altitude No measurements of decay signal • Noise - heigh altitude • Blue – data heigh altitude • Red – data production altitude Verification of SkyTEM 2002 Decay signal 600 m Noise signal 600 m SkyTEM Bias measurements High Altitude 600 m High Tx Moment only
SkyTEM 2009 Generator Rx Tx Coils Tx, Cooler & Control GPS & Radio Altimeter 16 meters 28 meters Altimiter Rx Coils Z & X Inclinometers
SkyTEM 2009 • Time gates: • ~ 10 ms - til 10 (20) ms • Ingen bias eller drift korrektion • Systemrespons fuldt beskrevet • Reproducerer reference data indenfor 5% • Repeterer testsite data bedre end 3% • Stiv bærekonstruktion • Stabile geometriske parametre
SkyTEM 2009 • Two-moment system • Lavt moment –overfladenær opløsning • 2.000 -10.000 Am2 • TurnOff ~ 2 - 6 µs • Højt moment –dybde opløsning • 150 -200.000 Am2 • TurnOff ~ 40 - 60 µs • Operationshøjde og -hastighed • ~ 20 - 35 meter • ~ 20 - 90 km/tim • Geometrical parametre målt • Højde, rammevinkler og DPGS • ”Stand Alone” (ingen operator i helikopter) • Vægt: 350 - 380 kg
SkyTEM i dag SkyTEM 2009 Radiosender Generator Modtager- & StyreElektronik Sender Areal: 300 – 500 m2 Vinkelmåler Højdemåler 16 meter 28 meter Højdemåler Modtagerspole 18:00
SkyTEM i dag Ups.. Radiosender Generator Modtager- & StyreElektronik Sender Areal: 300 – 500 m2 Vinkelmåler Højdemåler 16 meter 28 meter Højdemåler Modtagerspole Was the tree 40 meters high? 18:00
SkyTEM tekniske detaljer • Multi sender spoler • Geometrisk reduktion af bias • Reduceret harmonisk forvrængning • Analog gating styret digitalt
Senderen Sender Spole(r) Sender Tx Rx Spole Reference Rx Modtager
Senderen V L G R V 40 kV [e-R/L*t] ”R/L forløb” t
Senderen 1200 V V L G R V [ dI/dt = - V/L ] Avalanche forløb R/L forløb t
Senderen og målingen Avalanche forløb R/L forløb Jord response V Instrument Frontgate Primært respons måling starter Rx Tx Jord respons t Frontgate
Sender parametre TurnOff Spænding 1200 Volt Driv-spænding 12 Volt 0 Volt 100 Ampere 0 Ampere 10 milli sek. 30 mikro sek. Magnetisk Moment = areal x vindinger x strøm • TurnOff tid (Avalanche + R/L) prop. med: • (Selvinduktion) / (TurnOff spænding) • Strøm • Tidskonstant = (Selvinduktion)/ (dæmp. Mod.) • Selvinduktion prop. Med: • Længde • Vindinger 2 • TurnOn tid prop. Med: • (Selvinduktion) / (modstand) • 1 / Driv-spænding TurnOn tid TurnOff tid Strøm
Højt- og lavt moment sammen Avalanche forløb HM Avalanche forløb LM R/L forløb HM V Lavt Moment, LM (1 v, 150 uH)) R/L forløb LM Højt Moment, HM (4 v, 1600 uH) t
Højt- og lavt moment sammen Avalanche forløb LM R/L forløb LM koblet V Lavt Moment, LM (1 v, 150 uH)) R/L forløb LM ukoblet Kobling Højt Moment, HM (4 v, 1600 uH) t Frontgate
Højt- og lavt moment sammen Avalanche forløb LM Jord response R/L forløb LM koblet V Lavt Moment, LM (1 v, 150 uH)) Kobling Højt Moment, HM (4 v, 1600 uH) t Frontgate
Gate center tider fra 10 ms til 20 – 30 ms LM V HM t LM Tx Coil Coupling!! HM Tx Coil
Modtageren Sender spole Sender Tx Rx Spole Reference Rx Modtager
Gating Instrument (Rx) Sampler Integrator Digital Control Frontgate Rx log V • Problems to encounter___________ • dB/dt provides 107 dynamic ranges • Analog integrated gates provides less than 104 dynanic range 107 Frontgate sample sample sample 104 sample Integration of signal log t Gatewidth
Ingen bias korrection Reduktion af primært respons og lækage respons Modtagerspole TXspole 0 - position
Ingen bias korrection SkyTEM Signal i produktionshøjde Super Lavt Moment (SLM) Bias begravet i støjen (stor højde)
Frontgate log V primary response Instrument (Rx) Sampler 120 dB Integrator Digital Control t-2.5 earth response Frontgate t-1 harmonic distortion Rx log t
Frontgate Instrument (Rx) Sampler Integrator Digital Control Frontgate Rx log V primary response t-2.5 earth response 120 dB Frontgate log t harmonic distortion t-1
Synkronisering etc. TurnOff Tx 100 10 e-05 e-04 e-03 e-02 TurnOff tid • Efter instrument kalibrering: • Resterendeeffekter af: • Synkronisering • Tx TurnOff • Frontgate • korrigeres med tidsforskydning til at matche reference respons Reference signal FrontGate
Båndpas filtering Modtager spole Rx Integratorer Forstærkere Lowpas filtering 1000 400 kHz 100 kHz 100 40 kHz e-03 e-05 e-04 Støjreduktion: mindre båndbredde <<>> større forvrængning Rhoa (Ohmm) Rhoa (Ohmm)