1 / 19

Status of the rt CH- cavity

Status of the rt CH- cavity. - Anja Seibel -. Outline. CH- Cavity CH-Parameter Heat distribution Cooling concept Final CH- Cavity First measurement results. CH- Cavity. CH- Cavity. the CH- Cavity consists of 5 gaps with an operating frequency of 175 MHz

aiko
Download Presentation

Status of the rt CH- cavity

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Status ofthert CH-cavity - Anja Seibel -

  2. Outline • CH-Cavity • CH-Parameter • Heatdistribution • Coolingconcept • Final CH-Cavity • First measurementresults Anja Seibel

  3. CH-Cavity Anja Seibel

  4. CH-Cavity • the CH-Cavityconsistsof 5 gaps • with an operatingfrequency • of 175 MHz • thecavityhas a diameterof • about 770 mm (665,4 mm Tank • innerdiameter) and a lengthof • 463 mm (383 mm Tank inner • length) 34 mm 30 mm 770 mm 24 mm 21 mm 463 mm Anja Seibel

  5. CH-Cavity 4 1 3 2 1 Inductiveinputcoupler 4 Pick ups 2 Tuners 1 Vacuum pump port Anja Seibel

  6. CH-Cavity • The tuningisdone • bytwocylindrical • tuners. Oneis • adjustable in height • (80 mm) and • oneisstatic Anja Seibel

  7. CH-Cavity 220 mm Anja Seibel

  8. CH- Parameter Anja Seibel

  9. Heatdistribution rfcurrentdensitydistribution temperaturedistribution Anja Seibel

  10. Coolingconcept Coolingconceptforthedrifttubesandthestems Anja Seibel

  11. Coolingconcept Anja Seibel

  12. Coolingconcept • Coolingconceptforthe tank: • 16 coolingchannelswith a • diameterof 10 mm Anja Seibel

  13. Final CH-cavity Anja Seibel

  14. Final CH-cavity Anja Seibel

  15. Final CH-cavity Anja Seibel

  16. Final CH-cavity Anja Seibel

  17. First measurementresults Measurement Simulation Anja Seibel

  18. Electricalfieldprofile First measurementresults Simulation Measurement Anja Seibel

  19. Thanksforyourattention! Anja Seibel