0 likes | 11 Views
Existing and Proposed WWRP & CPU Shree Balaji Bio Fuels Solutions Jabalpur
E N D
Comparative sheet - Existing and Proposed WWRP & CPU Shree Balaji Bio Fuels Solutions,Jabalpur Description Sr. No. 1 Existing System Waste Water Treatment & Condensate Polishing Unit 480 KLD Proposed New System Waste Water Treatment & Condensate Polishing Unit 950 KLD Item 2 Treatment Capacity ( Total Feed Water ) Treatment Capacity ( Product Water after RO ) Reject Water from RO Recovery from RO Treatment Capacity ( MEE + ATFD ) Overall System Recovery Outlet Parameters 3 384 KLD 905 KLD 4 5 6 96 KLD 80% NA 45 KLD 95% 45 KLD 7 8 80% COD < 250 PPM TDS < 150 PPM CT Makeup ZLD , 99% COD < 250 PPM TDS < 150 PPM Process + CT Makeup Collection Anaerobic Digestor - Aeration Tank – Filtration Physico – Chemical Treatment Filtration Three Stage RO MEE – ATFD Treated Water Collection Tanks, UASBR Digestor , Aeration Tank , Tubesettlers , Chemical Dosing Systems , Flocculation Chamber , Tube settler , DMF , RO 01 , RO 02 , RO 03 , ACF , MEE , ATFD 9. End Use of Treated Water 10. Treatment Scheme Collection Physico Chemical Treatment Filtration -Two Stage RO Treated Water 11. Major Equipments used Collection Tanks, Air Blowwers, Chemical Dosing Systems , Flocculation Chamber , Tube settler , DMF , RO 01 , RO 02 , ACF