1 / 21

CEL-320 & 360 Noise dosimeters

CEL-320 & 360 Noise dosimeters An overview of the range of Casella CEL Personal noise dosimeters What models are available? CEL-320 personal noise dosimeter CEL-320S sound level meter CEL-360 logging noise dosimeter CEL-360S logging sound level meter

PamelaLan
Download Presentation

CEL-320 & 360 Noise dosimeters

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. CEL-320 & 360 Noise dosimeters An overview of the range of Casella CEL Personal noise dosimeters

  2. What models are available? • CEL-320 personal noise dosimeter • CEL-320S sound level meter • CEL-360 logging noise dosimeter • CEL-360S logging sound level meter • There are also intrinsically safe models available for all of the above versions

  3. CEL-300 models • Common features include • Cable microphone • Sealed keypad • Optional stalk microphone • Memory for 50 separate runs • Keypad lock • Long battery life

  4. What model is best? • For simple measurements of the overall noise exposure the CEL-320 is sufficient • For a more comprehensive understanding of the noise exposure using the time history or data logging function then the CEL-360 is better

  5. CEL-320 instrument main features 1 • 3 measurement ranges (30 – 140 dB) • Low 30 – 100 dB • Med 50 – 120 dB • High 70 – 140 dB • 2 frequency weighting • A and C • Separate peak frequency weighting • Lin or C

  6. CEL-320 instrument main features 2 • 3 time weightings (responses) • Slow, Fast and Impulse • 4 amplitude weightings (exchange rates, Q factor) • Q = 3, or 4 or 5 or 6 • 2 simultaneous threshold levels • Normally 80 and 90 dB • Single criterion level • Settable from 80 to 90 dB

  7. CEL-320 instrument main features 3 • Storage space in memory for up to 50 separate measurements • Every run tagged with start date and time • Calibration information stored with run • Pre run and post run date, time and level • Measures the overall total noise during run as a single figure for simple comparison against standards

  8. CEL-320 instrument main features 4 • Preconfigured named SETUPs for quick start using most popular settings • OSHA, MSHA, DoD, ACGIH, ISO85, ISO90 & METER • Just select from the list, load and run to begin • Icon in display shows run has started • Lock keypad and wait until the end of the run • Halt run, readout results from memory

  9. What measurements are stored 1? • For OSHA recordings • Actual noise dose%1 • Projected 8 hour noise dose%1 • Calculated TWA1 • Where results include noise above lower threshold level 80 dB • Same set for noise above upper threshold level 90 dB

  10. What measurements are stored 2? • Time average noise level • LAeq with Q=3 exchange rate • Lavg with Q=5 exchange rate • Sound exposure level • LAE with Q=3 exchange rate • Maximum noise level • Minimum noise level • Peak noise level

  11. What measurements are stored 3? • Up to 5 statistical percentiles (LN%) • LN10% • LN50% • LN90% • LN95% • LN99% • Used to describe the variation in the noise level from a distribution table stored during the run

  12. What other outputs are available? • Results can be viewed in display using DATA key • Results can be directly printed as a single page report • Results can be downloaded to standard CEL software package

  13. What are the benefits of the CEL-360? • Automatic recording using delay start/stop timers • Up to 16 sets of on/off times can be programmed into dosimeter • Run lengths of fixed duration • Storage of time histories to profile the noise during the run • Allows the time variation of noise levels to be displayed on the pc from the recording

  14. What sampling intervals can be used? • CEL-360 can sample noise levels • From 1 second fastest to 1 hour longest • Total memory size is over 220,000 data points • How long can a recording last • Over 60 hours for 1 value every 1 second • How many parameters can be sampled • Up to a maximum of 10 parameters can be stored every sampling interval in a run

  15. What are the benefits of logging noise? • Time history data logging provides very useful information for tackling excessive noise exposures • Focuses attention on noisiest periods during workday for correct usage of hearing protection or noise reduction at source

  16. What other accessories are available? • CEL-110/2 acoustic calibrator • Used to verify the accuracy of the dosimeter • Use before and after each run to check for any drift in measurements

  17. What is in a standard kit? • CEL noise dosimeter kits (eg. /K1) include • Calibrator – CEL-110/2 • Small foam windscreen – CEL-6225 • Download cable to pc – C6671 • Analysis Software • - CEL-6702 (dB10) for the CEL-320 models • - CEL-6704 (dB12) for the CEL-360 models • Kit case to hold all items – CEL-6682

  18. What other kits are available? • Multiple pack kits containing • 5 dosimeters and accessories (eg. /K5) • 10 dosimeters and accessories (eg. /K10) • Provides a single acoustic calibrator • One download cable • One set of software depending on dosimeter model

  19. What other accessories are available 1? • CEL-6648 Nylon pouch • Protects the dosimeter when used in dirty or harsh environments • Prevents possible damage to LCD or keypad • Discourages tampering with unit while being worn

  20. What other accessories are available 2? • C6672 printer interface cable • Allows results to be printed directly to any standard office printer without the need to download to pc first • Useful for field use with battery operated printer

  21. Where do I get more information? • Contact Casella CEL at 17 Old Nashua Road #15 Amherst NH 03031 TF (800) 366-2966 FX (603) 672-8053 E Info@CasellaUSA.com Web www.CasellaUSA.com