1 / 4

How An Ophthalmologist Gets An Accurate IOP Pressure With The Tonometer: Types a

<br>As an ophthalmologist, accurately measuring intraocular pressure (IOP) is very important to diagnosing and managing conditions such as glaucoma. While several different types of tonometersu2019 price & different ranges are available for measuring IOP, the tonopen has become a popular choice due to its ease of use, portability, and accuracy. In this article, weu2019ll explore how ophthalmologists use the different types of tonometer devices available and important tips to remember when using this technology.<br>

Jhon43
Download Presentation

How An Ophthalmologist Gets An Accurate IOP Pressure With The Tonometer: Types a

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. How An Ophthalmologist Gets An Accurate IOP Pressure With The Tonometer: Types and Tips To Use As an ophthalmologist, accurately measuring intraocular pressure (IOP) is very important to diagnosing and managing conditions such as glaucoma. While several different types of tonometers’ price& different ranges are available for measuring IOP, the tonopen has become a popular choice due to its ease of use, portability, and accuracy. In this article, we’ll explore how ophthalmologists use the different types of tonometer devices available and important tips to remember when using this technology.

  2. Different types of Tonometer Contact tonometry Tono-Pen (Reichert): A hand-held instrument provides the reading with a plunger that extends from a footplate and encounters the cornea. The plunger and footplate both encounter resistance when they contact the cornea. A reading of the accuracy percentage will also be included in the readout. They are transportable, simple to operate, and beneficial for people who struggle to sit behind a slit lamp. Icare ic100 tonometer: Icare ic100 tonometer price is the same as that of the tonopen device. It measures the rebound speed of a small magnetized probe. Rapid measurement makes taking pressure less traumatic for patients who dislike drops, such as children or patients with developmental disabilities, so the patient does not require anesthetic drops. Pneumotonometer (Reichert): This technique employs a silicone tip with windows that float on a stream of air and exerts increasing air pressure until it reaches the same level as the anterior chamber pressure. Non-contact tonometry This instrument is commonly referred to as the “air-puff” tonometer. It is excellent for use during screenings since it is precise in normal pressure ranges, does not require anesthetic drops, and requires less technical knowledge.

  3. Important tricks every ophthalmologist should know while using a tonopen To guarantee a precise and effective assessment with tonopen, ophthalmologists should keep the following advice in mind to ensure an accurate and efficient assessment: Let patients sit in a relaxed position; they shouldn’t struggle to reach the headrest. According to various research studies, patient positioning and constricting collars may impact IOP. Patients should concentrate on an area behind the technician. This prevents them from focusing on the tonometer tip, making them less likely to flinch as the device nears their eye. Instruct them to concentrate on keeping the other eye open wide; if they do so, applying pressure to the primary eye will be more challenging. Instruct them to elevate their brows and open their eyes in a “surprised” manner. It is far more difficult to close their eyes while exercising their brow muscles to elevate their brows. If patients cannot open their eyes, you must hold them open without applying any pressure to the eyeball. This can be accomplished by applying pressure to the patient’s cheekbones and brow bone. When using a tonopen, make sure the patient is looking ahead. An increase in IOP can be seen if the patient is looking superiorly, and a decrease in IOP can be seen with an inferior gaze. Always start with the same pressure on the dial. Do not set the dial’s number to the most recent IOP because doing so could make it simpler to “cheat” and convince yourself that you are close enough. After some practice, you can determine how far to turn the dial simply by looking at the mires when you first make contact.

  4. Once you’ve taken an IOP, examine the cornea. You will receive priceless information from this, such as any stains left behind from taking the measurement, which can help develop an improved technique. Also, you can observe alterations in corneal staining that weren’t necessarily there when the drop was first injected. Finally, calibrate frequently and maintain all instruments’ safety, cleanliness, and functionality. Conclusion By following these tips and using the appropriate tonometer device for each patient, ophthalmologists can obtain accurate IOP measurements and provide the best possible care for their patients. Content Courtesy https://theomnibuzz.com/how-an-ophthalmologist-gets-an-accurate- iop-pressure-with-the-tonometer-types-and-tips-to-use/

More Related