W930 EVT System Voltage fail analysis report

W930 EVT System Voltage fail analysis report. Prepared : Aaron Date: 2010-03-08. Fail item-1. 1. Fail item table. 2. Action: Widen the trace , and test if it is improved.It is also failed. Delete inductor L28 (&L63) ,it is passed. +1_05V_VCC_EXP,it is passed. Action:

zubeda
Download Presentation

W930 EVT System Voltage fail analysis report

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. W930 EVT System Voltagefail analysis report Prepared: Aaron Date: 2010-03-08

  2. Fail item-1 1. Fail item table

  3. 2. Action: Widen the trace , and test if it is improved.It is also failed.

  4. Delete inductor L28 (&L63) ,it is passed.

  5. +1_05V_VCC_EXP,it is passed.

  6. Action: 1.Enhance the source voltage of +1_05V_VTT, for example 40mV,change PR187 from 13.3k to 15k.

  7. Solution: 1.Enhance the source voltage of +1_05V_VTT, The value of Suggestion 30mV. 2.Improve Layout, Widen the power trace.

  8. 3. Action: Widen the trace , and test if it is improved. It is passed.

  9. PEX_VDD

  10. PEX_PLLVDD

  11. Action: 1.Enhance the source voltage of +1_05V_VTT, for example 20mV,change PR222 from 3.3k to 3.9k and PR229 from 10k to 11k.

  12. Solution: 1.Enhance the source voltage of PEX_VDD, The value of Suggestion 20mV. 2.Improve Layout, Widen the power trace.

  13. 4. Action: Widen the trace , and test if it is improved. It is passed.

  14. Solution: 1.Improve Layout, Widen the power trace.

  15. 4. Solution: 1.Improve Layout, Widen the power trace.