1 / 31

HVACR317 – Core for Refrigeration

HVACR317 – Core for Refrigeration. Motors Split Phase PSC CSIR CSCR. Split Phase Motors. Split phase motors are also called induction start - induction run motors. These motors use a current relay or a centrifugal switch to remove the start winding from the circuit.

xannon
Download Presentation

HVACR317 – Core for Refrigeration

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. HVACR317 – Core for Refrigeration Motors Split Phase PSC CSIR CSCR

  2. Split Phase Motors • Split phase motors are also called induction start - induction run motors. • These motors use a current relay or a centrifugal switch to remove the start winding from the circuit. • The start windings work on a phase shift principle.

  3. Split Phase Motor • The voltage from the start winding to the run winding is 10 degrees out of phase. • Starting torque and running torque are relatively low in split phase motors because the phase shift is so low.

  4. Split phase motors • These motors are used for belt drive blower applications such as small appliances like: • Washers • Dryers • Dish washers • Some older furnace blowers

  5. Split Phase Motors

  6. Split Phase Motor • The centrifugal switch removes the start winding from the motor circuit once the motor reaches around 75% of its rated speed. • This is the part that most often fails when a motor is started and stopped many times.

  7. Centrifugal Switch • The switch is normally closed when the motor is not operating.

  8. Centrifugal Switch

  9. Permanent Split Capacitor Motors • In order to increase the starting torque of a motor you can insert a capacitor in series with the start winding circuit. • In a PSC motor this capacitor remains in series while the motor is operating. There is no switch or relay that removes this capacitor from the circuit.

  10. PSC Motor • Residential Condenser fan motors and residential furnace blower motors are the primary use of PSC motors.

  11. PSC Motor • PSC motors have moderate starting torque and intermediate running efficiency. • These motors are used primarily for small compressors and direct-drive blower and fan applications.

  12. PSC Motor Example

  13. CSIR Motors • CSIR are capacitor start and induction run motors. • They use a start cap and a start relay. • Once the motor has reached 75% of its rated speed the start capacitor is removed from the circuit.

  14. CSIR motors • CSIR motors have a high starting torque and are used in residential and small commercial compressors. • May see them in beverage coolers or small reach ins.

  15. CSCR Motors • CSCR (Capacitor Start Capacitor Run) motors are the same as Permanent Split Capacitor motors except they have a start capacitor wired to them. • A start capacitor is a high capacitance capacitor that will provide the motor with additional torque when starting.

  16. CSCR Motors • Once the motor has been started it, the start capacitor must be taken out of the circuit using a switch or a relay. • These devices are called start components and this is covered in the next section.

  17. CSCR Motors • This motor can be abbreviated to CSR. (Capacitor Start and Run).

  18. CSCR Motor Example

  19. Hermetic Motors • Hermetic motors are single phase up to about 5 hp (horsepower). • Hermetic motors are those found inside the compressor shells. • They are wired the same way as any other split phase motor, but the start components must remain outside the compressor shell.

  20. Hermetic Motors

  21. Hermetic Motors • On the outside of the compressor shell there are three terminals. Most of the time these have some markings on them. • They are labeled C, R, S • S = Start winding • C = Common • R = Run Winding

  22. Hermetic Motors

  23. Motors • If the windings are not marked use your ohm meter and check resistance. • Check between all three windings. • The winding measurement with the highest resistance is between start and Run (S and R). The remaining terminal is Common ( or C).

  24. Motors • Once you know C check between C and the other two terminals the one with the highest resistance is S (or Start). • The one with the lower resistance is Run (or R).

  25. Motors • Best way to do this is to write down C, S, R in a triangle on a piece of paper and make sure you write down each measurement. • If you have any doubt - go back and do it again.

  26. Motor Speeds • Motor speeds are shown in RPM’s • RPM is revolutions per minute. This is a measure of how many times per minute the shaft rotates. • Sometimes you will need to figure out RPM’s for a motor.

  27. Motor Speeds • To figure motor speed first use the motor labels • If no label is found use the formula: • Speed (rpm) = (frequency x 120) / Poles

  28. Shaded Pole Diagram C R

  29. CSCR Diagram R C S

  30. Split Phase Diagram R C S

  31. PSC Diagram R C S

More Related