Product Presentation C-PTD 180/AIR/QC

Product Presentation C-PTD 180/AIR/QC. Air-cooled Peltier Temperature System. 28.02.2013. Content. Pictures Features and Benefits Specification Performance Measurements Special Features Article Number and Price Configuration Example Applications and Markets Competition Summary.

weldon
Download Presentation

Product Presentation C-PTD 180/AIR/QC

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Product Presentation C-PTD 180/AIR/QC Air-cooled Peltier Temperature System 28.02.2013

  2. Content • Pictures • Features and Benefits • Specification • Performance • Measurements • Special Features • Article Number and Price • Configuration Example • Applications and Markets • Competition • Summary 28.02.2013

  3. Pictures P-CTD 180/AIR/QC 28.02.2013

  4. Features and Benefits C-PTD 180/AIR/QC • Temperature Range Complete range: 0 °C to 180 °C • Measuring Systems Concentric Cylinder Measuring Systems Disposable Measuring Systems Stirrers and Spindles • Air-cooled Peltier system No counter cooling necessary • Typical Measurements Isothermal temperature tests Temperature ramps Temperature swing tests 28.02.2013

  5. C-PTD 180/AIR/QC - Specification • Temperature range 0 °C to 180 °C • Measuring systems Standard systems, DG42 • Beaker Standard beaker, max. CC39 or DG42 • General Good cleanability • Radiation system for counter cooling • Surrounding conditions • Temperature range 5 °C to 35 °C • Relative humidity, not condensing < 80 % • Altitude Up to 2000 m • Pollution Pollution degree 2 according to EN 61010 • Surrounding Laboratory, indoor us only • Supply • Supply voltage 85 to 265 V • Frequency 50 … 60 Hz • Overvoltage Overvoltage category II according to EN 6100 28.02.2013

  6. Technical Specification – Heating Rates Comparison Peltier / Liquid Temperature Control Heating rate (Peltier): 8.0 °C/min Heating rate (Liquid): 5.0 °C/min 28.02.2013

  7. Technical Specification – Cooling Rates Comparison Peltier / Liquid Temperature Control Cooling rate (Peltier): 4.0 °C/min Cooling rate (Liquid): 0.5 °C/min 28.02.2013

  8. Examples - Heating StableConditions after approx. 15 min 28.02.2013

  9. Examples - Cooling StableConditions after approx. 15 min 28.02.2013

  10. Special Features • Wide temperature range: 0 °C to 180 °C • Air cooled Peltier temperature system • Rapid changes in temperature • No external controller necessary • No counter cooling by an external circulator • Easy to install • Space saving design • Noise reduced 28.02.2013

  11. Article Number Item-no.108642 C-PTD 180/AIR/QC Peltier Temp. Control System Temp. range: 0 to 180 °C 28.02.2013

  12. Standard Configuration • Basic Instrument RheolabQC • 108642 C-PTD 180/AIR/QC • 20654 Disposable Measuring System CC39/D/QC-LTD • 20655 Disposable Measuring System CC27/D/QC-LTD • Option: • 18385 Software Rheoplus 28.02.2013

  13. Applications & Markets Coatings: Flow Curve, Yield Point, 3ITT (Thixotropy) Food: Flow Curve, Yield Point, Temperature Test, 3ITT (Thixotropy) Building Materials: Flow Curve, Yield Point, 3ITT (Thixotropy) 28.02.2013

  14. Applications & Markets Adhesives: Flow Curve, 3ITT (Thixotropy), Temperature Test Cosmetics: Flow Curve, Yield Point, Temperature Swing Test Pharma:Flow Curve, Yield Point, Temperature Swing Test Soft Gels: Yield Point, 3ITT (Thixotropy) Lubricants, Oils: Flow Curve, Temperature Test Asphalt: Flow Curve, Temperature Test 28.02.2013

  15. Summary C-PTD 180/AIR/QC is the new Peltier temperature system for the RheolabQC with: • Wide temperature range: 0 °C to 180 °C • Air cooled Peltier temperature system • Cheaper configuration compared with the liquid temp. control systems • Compact design, no counter cooling by an external circulator • Easy handling • Small footprint • Noise reduced compared to a fluid circulator • Low power consumption • Fast and accurate temperature setting • no thermal fluids/oil necessary • Firmware V1.26 for the RheolabQC required 28.02.2013