An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Usage of plural MentePC program April 2012

  2. ตัวอย่างโครงการใหญ่ๆ Master units = 12 Master units = 12 12 Systems Master units = 12 12 Systems Slave units = 12 12 Systems Slave units = 12 Slave units = 12

  3. Test run and Commissioning times Case A : 1 USB to 1ch RS232C 24 system must be measured 24 times. 40min x 24 times = 960min. Case B : 1 USB to 4ch RS232C 24 system must be measured 6 times. (4 Outdoor units can be get data at the same time) 40min x 6 times = 240min. If we use case B (1 USB to 4ch RS232C), We can save times of test run and commissioning job time. Master units = 12 Master units = 12 12 Systems Master units = 12 12 Systems Slave units = 12 12 Systems Slave units = 12 Slave units = 12

  4. Type of MentePC cable • 1 USB to 1ch RS232C • 2)1 USB to 4ch RS232C

  5. Specification of MentePC cable Male Female USB to RS232 converter Cross cable USB Female Male Female

  6. Create folder for MentePC Create folder for 4ch of MentePC

  7. Contents of MentePC folder 1) DATA Folder ----- DATA_e DATA_j 2) MessageData 3) MentePC_V4.2_01.xls *If we get data by 4ch RS232C at the same time the “MentePC_V4.2_01.xls must be different name.

  8. How to perform MentePC program 1) Open Microsoft Excel 2) File  Open  MentePC_V4.2_01.xls 3) Run MentePC program. 4) Enable Macro 5) Select Language 6) Accept 7) Select Mode 8) Save File Name Input 9) Set Log File Folder 10) Select data receiving 11) Sampling Time Setting 12) Select COM Port 13) Select RAMDATA 14) Start receiving log data

  9. File Name input Rule of File-naming X???YYYYMMDDhhmm****.csv X = R:Real time, S:Stored data, E:EEPROM ??? = User option YYYY=Year, MM=Month, DD=Day,hh=hour, mm=minute **** = _KX6, KE6C, KR6C, _KX4, _KR4, K4AC, KR4C, …. How do you define your option ? <Sample definition> Measurement or Address check M:Measurement of operation data, A:Address check Master or Slave M:Master outdoor unit, S:Slave outdoor unit Project name System(circuit) name ex. MM-WBL3F-SL1-16-3.3#B Measurement of operation data Master outdoor unit System name (SuperLynk 1, Outdoor unit address 16, 3rd floor, No.3, B:Indoor unit 17-32) Project name (ex. Watabe BuiLding)

  10. Sample of MentePC graph