An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Conceptpower Modular 80 and 100kVA THE BEST WAY TO PREDICT THE FUTURE IS TO INVENT IT

  2. Unique Power ProtectionConcept (PPC) 6 Key-Features at a Glance • Modularity • Redundancy • Scalability • Environmentally Friendly • Serviceability • Manageability

  3. Static Bypass Load Rect. Boost. Inverter Batt. Batt. Charger ConceptpowerTM Modular Modularity • First and unique hot swappable 3phase double conversion (VFI) UPS modular design • 2 possible power ranges:80 and 100kVA Welcome to the future of power protection

  4. ConceptpowerTM Module Front view 80-100kVA • Active module includes: • Rectifier & Booster • Battery charger • Inverter • µProcessor control board • Passive module includes: • Input filter • Output filter • Booster coils • Static By-pass

  5. ConceptpowerTM Module Dry contacts NC/NO, D25P/Fconnection Smart port RS232 Front view 80-100kVA By-pass line fuses EPO, Gen-on, Batt.temp.connector Module Interfaceconnector LCD Display Panelconnector ComBus Module to Module

  6. ConceptpowerTM Module Rear view 80-100kVA Weight of the active module 80-100 kVA: 55-60 Kg Size of the UPS module:667x412x834mm (WxHxD) Weight of the passive module 80-100 kVA: 55-60 Kg Size of the UPS module:667x412x834mm (WxHxD)

  7. ConceptpowerTM Module Inside view 80-100kVA µ Control board Batt. Charger Input LC FIlter By-pass Inverter Booster DC Cap. Output LC Filter

  8. ConceptpowerTM Modular Power modules: 80-100 kVA Upgrade frame 300 kVA Welcome to the future of power protection

  9. UPS – module 3 UPS – module 2 UPS – module 1 Distribution 300kVA ConceptpowerTM Modular UPGRADE FRAME Power modules: 80-100kVA • Limited up to 10 modules in parallel (> 10 modules on request) • Distribution section for the max. capacity (300kVA) • No single point of failure • Space saving, 300kVA in 1.22 sqm.

  10. ConceptpowerTM Modular UPGRADE FRAME DISTRIBUTION 300KVA Modules output disconnects Centralized SNMP Slot (Multidrop). RS232, PFC, EPO DPA extension bus Centralized MaintenanceBy-pass

  11. UPS – module 3 UPS – module 2 UPS – module 1 Distribution 300kVA ConceptpowerTM Modular - Scalability • Optimized capital investment by extending your power protection capacity at a pace that fits your business on demand • Scalable performance of the power capacity and runtime by simply adding independent UPS or battery increments Upgrade Frame (Vertical Scalability) (floor-saving-frame)

  12. 1997/06/03 10:54:36 5ms/div Input Voltage Input Current (5ms/div) NORM:200kS/s 6-pulse rectifier 12-pulse rectifier ConceptpowerTM Modular Environmentally Friendly • Sinewave input current (THD=7-9%) • Input PF=0.98 in a standard versionThis means: • Smaller cables size and lower losses • Smaller fuses or Circuit Breakers (no malfunction and false tripping) • No separate phase compensation required • No extra heating of transformer and generators oversized No additional hardware for harmonic reduction is required

  13. ConceptpowerTM Modular Environmentally Friendly • Highest double-conversion efficiency ESIS (Energy Saving Inverter Switching) up to 95% in on- line, double conversion mode • Load dependent audible noise • Wide input frequency windows (35-70Hz) • Low weight (3x100kVA: 700kg) • Compact size (3x100kVA: 1.22 sqm) The total annual operating costs for a Newave UPS can be >40% less compared to those for a previous generation

  14. UPS – module 3 Harmonic Filter & PFC 12 Pulse 12 Pulse Harmonic Filter & PFC UPS –1 UPS –2 UPS –1 UPS –2 UPS – module 2 UPS – module 1 Distribution 200kVA Distribution 200kVA Distribution 300kVA Modular 3x100kVA Total footprint required: 1.22 sqm Total weight: 700Kg MAXI 2x200kVA Total footprint required: 1.8 sqm Total weight: 1280Kg Legacy 2x200kVA UPS configuration 6 Pulse UPS (2x1.24 sqm) 12 Pulse rectifier (2x0.55 sqm) Harmonic Filter& PFC (2x0.55 sqm)Total footprint required: 4.68 sqmTotal weight: >3500Kg ConceptpowerTM Modular Environmentally Friendly Product positioning Case 1: configuration required 2x200kVA redundant

  15. UPS – module 3 UPS – module 6 Harmonic Filter & PFC Harmonic Filter & PFC UPS –1 & 12 Pulse UPS –2 & 12 Pulse UPS –3 UPS –1 UPS –2 UPS – module 2 UPS – module 5 UPS – module 4 UPS – module 1 Distribution 250kVA Distribution 250kVA Distribution 250kVA Distribution 300kVA Distribution 300kVA MAXI 3x250kVA Total footprint required: 2.7 sqm Total weight: 1980Kg Modular 6x100kVA Total footprint required: 2.44 sqm Total weight: 1400Kg Legacy 2x500kVA UPS configuration 12 Pulse UPS (2x2.1 sqm) Harmonic Filter& PFC (2x0.88 sqm)Total footprint required: 5.96 sqmTotal weight: >6200Kg ConceptpowerTM Modular Environmentally Friendly Product positioning Case 2: configuration required 2x500kVA redundant

  16. Legacy UPS Conceptpower UPS Battery cost saving • Flexible Battery Management (FBM) • Variable DC-voltage enabling the use of battery blocks(40-50 blocks of 12VDC) • Wide input voltage windows (-23%/+15% @100% load) (-30%/+15% @<80% load) (-40%/+15% @<60% load) Less need for battery operation • Automatic battery test with algorithm CPU controlledEarly warning in case of battery fault • Temperature compensationIncreases battery lifetime • Ripple free through battery chargerLonger battery life time

  17. ConceptpowerTM Modular Serviceability • Modular and hot-swappable design means minimizing service and maintenance cost and • Reduction of MTTR, maximize your power protectionavailability • Front access only • No needs for skilled personnel on site • No need of spares, just modules

  18. ConceptpowerTM Modular Manageability • Redundant Power Management Display advances the Power Protection Manageability • Common data execution functions for parallel systems onredundant parallel PMD’s. • The complete parallel system may be managed by any one of the parallel PMD’s. • PMD consists of mimic diagram for system status, push buttons for single module and parallel system control and LCD for monitoring, event logs and diagnosis.

  19. LCD Display ON / OFF LINE 2 BY PASS BATTERY ALARM RESET ENTER ON / OFF LINE 1 INV ConceptpowerTM Module Display Most important information available at first glance

  20. ConceptpowerTM Modular Remote Control and Shutdown • Remote Signalling Panel (RSP)For Status and Alarm Remote Indications • Wavemon (CD)For Automatic Server shutdownand Monitoring. Cross Platform shutdown available • SNMP-card or Box for connection of UPS in Network Management systems

  21. 10 reasons for buying ConceptpowerTM Modular 1. Optimize capital investment and available spacePay-as-you-grow solution lowers your capital costs and increases utilization rates, while innovative rack-based technology frees up space previously needed for infrastructure support. 2. Adapt to ever-changing power requirementsNo need to abandon previous investment when power density needs increase or if physically moving your data centre. Adapt to changing wattage requirements in your racks with single- or multi-branch rack-mount power distribution units. 3. Accelerate speed of deploymentElectrical and physical modularity allows for rapid installation with minimal engineering. 4. Lower the cost of service contractsSimplicity of system design and intelligent modular parts lessen the dependency on expensive service contracts. 5. Increase availability Specifically engineered to deliver higher availability through proactively designed, building block architecture and reduced MTTR

  22. 10 reasons for buying ConceptpowerTM Modular 6. Decrease mean-time-to-recovery (MTTR)Compartmentalize potential failures with system components consisting of intelligent, maintainable modules for quick fault recovery. 7. Plan for a power density that is increasing and unpredictableEliminate hot spots in your data centre caused by higher power densities by targeting availability where you need it most. 8. Minimize points of failure between the UPS and the critical loadMove redundancy closer to the load and prevent the majority of failures that cause critical load downtime. 9. Minimize human errorSimplicity of design and intelligent modules increase system availability by mitigating human error: the number one cause of critical load downtime. 10. Decrease the operating costsWith efficiency up to 95% (double conversion mode), theoperating costs for a Conceptpower modular UPS can be >40% less compared to those for a previous generation

  23. Swiss Quality Power Protection Leader Through Innovation • INNOVATION • SUPPORT • QUALITY TO PROTECT YOUR MISSION CRITICAL APPLICATIONS