An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Integration AC System

  2. Overview This doc is created to show all the possibilities of integration with 3rd party AC system. Toshiba AC of Bacnet, CoolMaster, DAKIN AC, DAKIN Modebus AC, Media AC, ADVANTAGE AIR, Gelingsi, Samsung, Coolink AC, Board AC, Gree Modebus AC, HITACHI AC… HDL products mentioned in this doc: SB-DN-1IP SB-DN-RS232N

  3. Toshiba AC of Bacnet Control BACnet AC system: 1. Diagram 2. Current firmware version for SB-DN-1IP FW_HDL-BN-VRV_V1.00(2013-06-03)

  4. Toshiba AC of Bacnet Control BACnet AC system: 3. Note. “FW_HDL-BN-VRV_V1.00(2013-06-03)” supports Toshiba AC system only, more brands can be added when requested. “FW_HDL-BN-VRV_V1.00(2013-06-03)” supports 128 Toshiba indoor units. The corresponding Toshiba module for “FW-HDL-BN-VRV_V1.00(2013-06-03)” is BMS-STBN08E, spec date 1 October, 2006. Functionalities (DLP AC page): AC On/Off, Room temperature (sensor in DLP panel, cannot get room temperature from AC system), Setpoint, High/Medium/Low/Auto wind, Cooling/Heating/Auto/Dry mode. Disable the option “Control AC Running” in DLP.

  5. Toshiba AC of Bacnet Control BACnet AC system: Application: (use DLP to control Toshiba AC via SB-DN-IP) Upgrade the firmware ‘FW_HDL-BN-VRV_V1.00(2013-06-03)’ on SB-DN-1IP; After upgraded, it will be HDL-BN-VRV, set the 3rd party bacnet gateway information; In DLP, set the ID of HDL-BN-VRV in AC page.(e.g. control the AC in room2) If enable, can be used as gateway to search HDL devices. Ip of 3rd party’s bacnet gateway

  6. HDL Buspro CoolMaster Use CoolMaster module to control AC system: 1. Diagram 2. Current firmware version for SB-DN-RS232N FW_HDL-CM_V4.05U(2015-07-23)

  7. CoolMaster Use CoolMaster module to control AC system: 3. Note. Different brand AC system needs different CoolMaster module, e.g., module 1000D is for Daikin AC, 2000S is for Sanyo AC, 3000T is for Toshiba AC, etc. For more info, please visit CoolMaster official website http://coolautomation.com/ , all CoolMaster modules have unified interface (RS232) to interface with SB-DN-RS232N. “FW-HDL-CM_V4.05U(2015-07-23)” supports 64 AC indoor units. Functionalities (DLP AC page): AC On/Off, Room temperature (sensor in DLP panel), setpoint, High/Medium/Low/Auto wind, Cooling/Heating/Auto/Dry mode. Disable the option “Control AC Running” in DLP.

  8. CoolMaster Use CoolMaster module to control AC system: Application: use DLP to control CoolMaster 9000H. Check the CM System ID and CM Group ID on CoolMaster 9000H; In SB-DN-RS232, fill in the CM System ID and CM Group ID;(see HDL AC 2) In DLP AC page, fill in the ID of SB-MCM, and set AC number as 2.

  9. HDL Buspro DAIKIN AC Control DAIKIN AC via a specific DAIKIN RS485 interface 1. Diagram

  10. DAKIN AC Control DAIKIN AC via a specific DAIKIN RS485 interface 2. Current firmware version for SB-DN-RS232N: FW_SB-DN-RS232N(DAIKIN)_V4.03U(M64_2014-11-11) 3. Note: The specific DAIKIN RS485 interface module - DRCH-R5, is made by Shanghai DAIKIN Air Conditioning Co., LTD, one such interface module can connect up to 3 indoor units and the spec of the interface module is SZ-02120301. Functionalities (DLP AC page): AC On/Off, Room temperature (sensor in DLP panel), setpoint, High/Medium/Low/Auto wind, Cooling/Heating/Auto/Dry mode. Disable the option “Control AC Running” in DLP. There is no RS485 interface soldered on the SB-DN-RS232N by default, need to specify when order.

  11. DAIKIN Modebus AC Control DAIKIN AC via Modebus module (DTA116A51) 1. Based on Daikin spec “Programmer’s Manual Home Automation I/F adaptor for VRV, 26 May 2011” HDL buspro system DAIKIN Modebus model: DTA116A51 DⅢ-NET/Modebus Communication adaptor

  12. DAIKIN Modebus AC Control DAIKIN AC via Modebus module (DTA116A51) 2. Current firmware version for SB-DN-RS232N: FW_SB-DN-RS232N-AC232_V02.02U(2015-10-23) 3. Note: Functionalities (DLP AC page): AC On/Off, Room temperature (sensor in DLP panel), setpoint, High/Medium/Low/Auto wind, Cooling/Heating/Auto/Dry mode. Disable the option “Control AC Running” in DLP. There is no RS485 interface soldered on the SB-DN-RS232N by default, need to specify when order.

  13. Media AC Control Media AC via RS485 port 1. Based on a Chinese spec “美的商用空调网络控制通讯协议V1.4 邓永忠2006-12-4”; If the Media AC used this protocol, then can use SB-DN-RS232N (Media AC version) to control. 2. Current firmware version for SB-DN-RS232N: FW_SB-DN-RS232N-AC232_V02.02U(2015-10-23) 3. Note: Functionalities (DLP AC page): AC On/Off, Room temperature (sensor in DLP panel), setpoint, High/Medium/Low/Auto wind, Cooling/Heating/Auto/Dry mode. Disable the option “Control AC Running” in DLP. There is no RS485 interface soldered on the SB-DN-RS232N by default, need to specify when order.

  14. ADVANTAGE AIR Control ADVANTAGE AIR via RS485/RS232 port 1. Based on “GENERATION III HOME AUTOMATION GATEWAY Serial Communication Protocaol – Instruction Set. Version 2.0 Revision 12/09/06” 2.Current firmware version for SB-DN-RS232N: FW_SB-DN-RS232N-AC232_V02.02U(2015-10-23) 3. Note: Functionalities (DLP AC page): AC On/Off, Room temperature (sensor in DLP panel), setpoint, High/Medium/Low/Auto wind, Cooling/Heating/Auto/Dry mode. Disable the option “Control AC Running” in DLP. There is no RS485 interface soldered on the SB-DN-RS232N by default, need to specify when order.

  15. Gelingsi AC Control Gelingsi AC via RS485 port 1. No standard spec (doc ref. no.) from Gelingsi company 2. Current firmware version for SB-DN-RS232N: FW_SB-DN-RS232N-AC232_V02.02U(2015-10-23) 3. Note: Functionalities (DLP AC page): AC On/Off, Room temperature (sensor in DLP panel), setpoint, High/Medium/Low/Auto wind, Cooling/Heating/Auto/Dry mode. Disable the option “Control AC Running” in DLP. There is no RS485 interface soldered on the SB-DN-RS232N by default, need to specify when order.

  16. Samsung AC Control Samsung AC via RS485 port 1. Based on spec “Samsung RS485 communication protocol V1.1” If the Samsung AC used this protocol, then can use SB-DN-RS232N (Samsung AC version) to control. 2. Current firmware version for SB-DN-RS232N: FW_SB-DN-RS232N-AC232_V02.02U(2015-10-23) 3. Note: Functionalities (DLP AC page): AC On/Off, Room temperature (sensor in DLP panel), setpoint, High/Medium/Low/Auto wind, Cooling/Heating/Auto/Dry mode. Disable the option “Control AC Running” in DLP. There is no RS485 interface soldered on the SB-DN-RS232N by default, need to specify when order.

  17. Coolink AC Control Coolink AC via RS485/RS232 port 1. Based on CooLink Programmers Reference Manual, Document Revision 0.8 7/15/2012 2. Current firmware version for SB-DN-RS232N: FW_SB-DN-RS232N-AC232_V02.02U(2015-10-23) 3. Note: Functionalities (DLP AC page): AC On/Off, Room temperature (sensor in DLP panel), setpoint, High/Medium/Low/Auto wind, Cooling/Heating/Auto/Dry mode. Disable the option “Control AC Running” in DLP. There is no RS485 interface soldered on the SB-DN-RS232N by default, need to specify when order.

  18. Board AC Control Board AC via RS485 port 1. Connect to RSM-B4 module, based on a Chinese spec “远大RSM-B4 485通信协议.pdf”, http://en.broad.com/index.html 2. Current firmware version for SB-DN-RS232N: FW_SB-DN-RS232N-AC232_V02.02U(2015-10-23) 3. Note: Functionalities (DLP AC page): AC On/Off, Room temperature (sensor in DLP panel), setpoint, High/Medium/Low/Auto wind, Cooling/Heating/Auto/Dry mode. Disable the option “Control AC Running” in DLP. There is no RS485 interface soldered on the SB-DN-RS232N by default, need to specify when order.

  19. HITACHI AC Control HITACHI AC via RS485 port 1. Based on a Chinese spec “HLRSCON与上位机通信制御仕样书”, doc ref. no. is HAPQ图号H7X00007, made by Qingdao Hisense Hitachi Air Conditioning Company 2. Current firmware version for SB-DN-RS232N: FW_SB-DN-RS232N-AC232_V02.02U(2015-10-23) 3. Note: Functionalities (DLP AC page): AC On/Off, Room temperature (sensor in DLP panel), setpoint, High/Medium/Low/Auto wind, Cooling/Heating/Auto/Dry mode. Disable the option “Control AC Running” in DLP. There is no RS485 interface soldered on the SB-DN-RS232N by default, need to specify when order.

  20. Gree Modebus AC Control Gree Modebus AC via RS485 port 1. Based on a Chinese spec “多联机Modbus通讯协议V1.2” 2. Current firmware version for SB-DN-RS232N: FW_SB-DN-RS232N-AC232_V02.02U(2015-10-23) 3. Note: Functionalities (DLP AC page): AC On/Off, Room temperature (sensor in DLP panel), setpoint, High/Medium/Low/Auto wind, Cooling/Heating/Auto/Dry mode. Disable the option “Control AC Running” in DLP. There is no RS485 interface soldered on the SB-DN-RS232N by default, need to specify when order.