1 / 18

MICE Beamline Analysis – TRD SEPT04

MICE Beamline Analysis – TRD SEPT04. Tom Roberts Muons, Inc. February 10, 2005. Outline. Brief Summary of the SEPT04 beamline design Updated for the December 17 TRD Brief Summary of this simulation Summary of rates Particle Distributions in PID Counters and the downstream IronShield.

sovann
Download Presentation

MICE Beamline Analysis – TRD SEPT04

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. MICE Beamline Analysis – TRD SEPT04 Tom Roberts Muons, Inc. February 10, 2005 MICE Beamline Analysis -- TRD SEPT04

  2. Outline • Brief Summary of the SEPT04 beamline designUpdated for the December 17 TRD • Brief Summary of this simulation • Summary of rates • Particle Distributions in PID Counters and the downstream IronShield MICE Beamline Analysis -- TRD SEPT04

  3. TRD SEPT04 Layout ISIS Beam Iron Shield TOF0 TOF1 Diffuser Iron Shield TOF2 Ckov2Cal Proton Absorber Ckov1 MICE Beamline Analysis -- TRD SEPT04

  4. Summary of the SEPT04 Beamline Design * The intent of the design is for 206 MeV/c in Tracker1, but various energy losses were not accounted for in the design; this is the actual value achieved. MICE Beamline Analysis -- TRD SEPT04

  5. Summary of this Simulation • A significant improvement in realism: • First guess of the beamline vacuum, windows, air gaps, etc. • More detailed implementation of Tracker1 and Tracker2 • Vacuum with windows • 5 planes, 1.5 mm scintillator each, located as in the TRD (Dec 17 2004) • TRD (Dec 17 2004) configurations for everything except a few minor things (absorber and RF window shapes) MICE Beamline Analysis -- TRD SEPT04

  6. Summary of Rates Values are events per millisecond of Good Target; absorbers empty, no RF. Good μ+ = TOF0 & TOF1 & Tracker1 & Tracker2 & TOF2 & TOF1(μ+) & TOF2(μ+) Major changes from before:2 in. total thickness of TOF0 and TOF1  ~20% reduction in Good μ+~50% larger target acceptance  ~10% increase in TOF0 singles, ~1% in Good μ+. MICE Beamline Analysis -- TRD SEPT04

  7. Momentum Histograms (Placed together to facilitate comparisons) MICE Beamline Analysis -- TRD SEPT04

  8. PID Counter Distributions • Same simulation, except: • The downstream IronShield is physically removed • Its effect on the magnetic field remains • Replaced by a virtualdetector 800 mm square (Air) at its downstream face • All counters are made large enough to see everything • TOF0, TOF1, TOF2 are 800 mm square • Cherenkov1 is 800 mm square • Tracker1 and Tracker2 are 200 mm in radius • Cherenkov2 is 800 mm in radius • Calorimeter is 2000 mm square • Relaxed ThroughParticle Trigger: requires only 15 hits out of 17 counters (i.e. nothing after TOF2 is required) • Good-μ+ = ThroughParticle & TOF1(μ+) & TOF2(μ+) • The TRD size of each counter is displayed as a green overlay on each plot. MICE Beamline Analysis -- TRD SEPT04

  9. TOF0 TRD Size 480x480 MICE Beamline Analysis -- TRD SEPT04

  10. Cherenkov1 TRD Size 400x400 MICE Beamline Analysis -- TRD SEPT04

  11. TOF1 TRD Size 480x480 MICE Beamline Analysis -- TRD SEPT04

  12. Iron Shield (hole) TRD Size r=250 Missed mu+ = 8, Singles=1326 Good mu+=1321 MICE Beamline Analysis -- TRD SEPT04

  13. TOF2 - X TRD Size 480x480 Missed mu+ = 5, Singles=1326 Good mu+=1321 MICE Beamline Analysis -- TRD SEPT04

  14. TOF2 - Y TRD Size 480x480 Missed mu+ = 4, Singles=1326 Good mu+=1321 MICE Beamline Analysis -- TRD SEPT04

  15. Cherenkov2 - r TRD Size r=400 Missed mu+ = 3, Singles=1326 Good mu+=1321 MICE Beamline Analysis -- TRD SEPT04

  16. Calorimeter - X TRD Size 1200x1200 Missed mu+ = 1, Singles=1326 Good mu+=1321 MICE Beamline Analysis -- TRD SEPT04

  17. Calorimeter - Y TRD Size 1200x1200 Missed mu+ = 1, Singles=1326 Good mu+=1321 MICE Beamline Analysis -- TRD SEPT04

  18. Conclusions • The December 17, 2004 TRD includes minor changes from earlier beamline analyses. • The major one is in TOF thicknesses, which costs about 20% in the good mu+ rate • The PID counter sizes in the TRD miss ~0.7% of the good mu+. • The hole in the downstream IronShield kills ~0.6% of the good mu+. Most of these are the same mu+ missed by TOF2. MICE Beamline Analysis -- TRD SEPT04