An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Variation in extracerebral layer (ECL) thickness within a subject and between subjects Tae Sun Yoo Department of Medical Biophysics University of Western Ontario Supervisor: Dr. Keith St Lawrence and Ph.D. candidate Jonathan Elliott

  2. Near Infrared Spectroscopy & Principles • Near infrared spectroscopy is a powerful optical technique used to measure cerebral blood flow (CBF) and cerebral blood oxygenation. Blood Flow Technique: Bolus injection light-absorbing dye, indocyanine green (ICG) Monitor passage of ICG through brain by NIRS 3) CBF determined by shape of time-concentration data

  3. Clinical Relevance of NIRS • Brain injury is a leading cause of deaths and disability in Canada. • NIRS can be used to assess brain health at the bedside of head-trauma patients • NIRS works well with infants, but not with adults • Problem is signal contamination from extracerebral layer • Consequence is reduced sensitivity to brain leading to underestimation of CBF.

  4. Approach • MRIcro was used to import MRI images and Image J was used to obtain length of extracerebral layer (ECL) thickness values across the circumference of the head (from 0 to 360˚)

  5. Hypothesis • Variations in ECL thickness across the subject will be sufficient to affect the NIRS brain attenuation signal to measure accurate cerebral blood flow (CBF).

  6. Method • Brain MRI images were acquired from five young healthy subjects & viewed by MRIcro. • Anterior Commissure (AC) was chosen as the reference location for all subjects • MRI images were exported in 2 transverse slices per subject.

  7. Method • Brain MRI images were loaded onto “ImageJ”. • By using a line tool and fill function, outlines were drawn from 0 to 360˚ within the image. • Color picker function was used with pencil tool. land markers were made at two locations. • Total (ECL) thickness measurements were done by moving a line tool at 10˚increment with use of measurement function.

  8. 90˚ Angle (θ) Position 180˚ 0, 360˚ 270˚ Note: MR images were calibrated by 1 x 1 mm ECL thickness Scalp Angle (θ) from 0° to 360° Record: Total ECL thickness made by Δ10° increment Skull

  9. Results

  10. *p < 0.05 ∆ in ECL thickness between AC & AC +20mm:  ECL thickness was slightly thinner at AC above 20mm!

  11. Subject 3, AC, Region I 9% • As ECL thickness increased, % of brain signal is reduced

  12. ICG concentration (uM) Pure brain curve Pure scalp curve Time (s) ICG concentration (uM) ICG concentration (uM) Time (s) Time (s) Mean, AC+20, Region I Brain contribution: 35% Subject 3, AC, Region I Brain contribution: 9%

  13. Discussion Main limitations: There isn’t a decent imaging tool which resolves different ECL layers separately. • Source of errors: . Small sample size (5 subjects) . Resolution of MR image quality (reduced with “zoom in” function)

  14. Discussion Future works on identifying ECL thickness variability: • By standardizing variation of ECL thickness, more precise and reliable CBF measurements can be made on adults. • In near future, individualized approach on making an adjustment on CBF measurements are possible by removing ECL (skull and scalp) contamination.

  15. Conclusion • Mean ECL thickness across the circumference from subject 1 to 5 at AC+20mm was thinner by 2mm than at AC. • Based on regions (I-IV), forehead region I at AC above 20mm was shown to be the thinnest mean ECL thickness. • Thus, thinner the ECL thickness, better the CBF measurements by increased in contribution of brain signal (more light propagates into brain and reduced ECL contamination).