An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Pixel Detector Control System1st training sessionMay 10, 2007 Overview CANbus and ELMB Pixel DCS Computers in the pit ELMB integration ELMB control CAN PSU Susanne Kersten, Wuppertal University

  2. Overview

  3. Hardware of the Pixel Control System

  4. Further Hardware of the Pixel Control System • What is missing on the overview figure: • Aux Power Supplies • PP2 PS (WIENER PS)PP3 PS (custom made device to power BBIMs) CAN PSU • Opto PP3 (patch panel) • Monitoring of DAQ hardwareVME crate control (via CANbus interface) BOC parameters (via DDC, DAQ-DCS-Communication) BOC Temp. monitoring (via CAN) • Details of Interlock SystemLogic Unit Interlock Distribution Boxes BOC-I-Box PP1 Box Opto Heater Ilock & Beampipe BakeOut Ilock

  5. FSM SIT FITs Software of the Pixel Control System Pixel specific termini: FITs: front end integration tool functional order SIT: system integration tool geographical/detector oriented order ATLAS DCS configuration DAQ DDC connectivity conditions Hardware 1 Hardware 2 Hardware 3 Hardware n

  6. DCS software • In most cases CANbus is used to establish communication between hardware and DCS PCs (see next section) • DCS software is based on PVSS (ProzessVisualisierungs- und SteuerungsSystem, commercial tool, used CERN wide) • On each DCS PC several PVSS projects can be running, independent of each other • The FITs, special PVSS (sub)projects, communicate with the hardware, e,g, a LV power supply, a HV power supply or an ELMB. These FITs will be handled in 1st and 2nd session of the DCS training. • Higher level control software: • SIT System integration tool (3rd session) • FSM (finite state machine) • RDM manager, PVSSdataViewer, PVSS2COOL etc… • DDC (DAQ DCS Communication) Next DCS training sessions

  7. Introduction to CANbus and ELMB

  8. Control Area Network Serial fieldbus, communication standard chosen for its reliability One needs • a CAN interface in the PC • cables (‘CANbus’), for short distances typically sub D9 connector and flat cable • CANnodes connected to the bus: ELMB (subject of this session) • termination of CANbus cable • In some cases a CAN power supply unit (CAN PSU) • 3 different interfaces in use: • Peak for iseg HV System • Kvaser (up to 4 ports) • Systec USB (up to 2* 8 ports)

  9. Embedded Local Monitor Board Altogether we have 630 CANnodes in the pixel DCS 485 are of type ELMB ELMB: • Standard ATLAS frontend IO unit for DCS • ATMEGA128 microprocessor • 24 digital IO channels • 64 channel, multiplexed ADC 16 bit with selectable range • CAN interface • speaks CANopen ELMB top view (credit card size)

  10. Settings of an ELMB node don‘t touch! Speed depends on max. cable length, 125 kbit/s ↔ max. 250 m No identical node IDs on the same CANbus!Not more than 32 nodes on one busDon‘t mix CAN nodes of different flavour on one bus Figure taken from ElmbUserGuide (J. Cook)

  11. DCS crate ELMB ELMB ELMB ELMB ELMB ELMB Typical CANbus DCS PC CAN PSU • A CAN bus for ISEG or VME crate control looks the same besides that there is no CAN PSU required • Please note the CAN PSU is necessary for the operation of the ELMB, but not a sufficient requirement for operation of some DCS crates! 120Ω ELMB CAN interface ELMB CAN interface long, thickCAN cable(CAN signals + CAN power lines) CAN interface ELMB thin CAN cable(CAN signals) 120Ω

  12. OPC server / client • Protocol on the CANbus is CANopen • The ELMBs are communicating via CANbus to the OPC server • Name: CANOPEN25+.exe (see task manager) • The clients (PVSS projects, see below) connect to the OPC server in order to send or receive data • Client is one of the ‚managers‘ (PVSS processes) client

  13. Winhost programs Simple tool to check whether your ELMB is responding properly For Kvaser cards: Winhost+.exe For systec: Winhost+Rel.exe proper icon on desktops select port = CANbus ID Always Kvaser+ Bus scan! check whether your ELMB has shown up! check if the number of nodes is as expected

  14. Pixel DCS Computers In the Pit

  15. Pixel DCS-net in the Pit Our computers: PCATLPIX….. e.g. PCATLPIXSCS (Sub-detector Control Station) • https://twiki.cern.ch/twiki/bin/view/Atlas/PixelDCS • → PCs in USA15 status May 8, 2007 Always check the actual status on the wiki!!!

  16. Pixel DCS-net in the Pit Always check the actual status on the wiki!!!

  17. How to log in • there is no common pixel account • ask susanne.kersten@cern.ch for access rights • then log in with nice username and password Via terminals directly connected to PCs: • Location of PCs in rack Y.12-14.A2 in USA counting room • In neighbouring racks 10-14 and 11-14 two screens • Double click ‘ctrl’ shows you which machines are connected to the screen and allows you to make your choice • Your personal username/password

  18. How to login Or via double remote desktop: (1) remote desktop to cerntsatldcs01.cern.ch (your nice username/passwd) → remote desktop Select the PC (again nice username/passwd) (2)

  19. Access to PVSS projects • Look on the DCS wiki page for the required project name • check in the PVSS Project Administration (desktop) whether the project is running, should be! • if it not around, start your project via the Services console (desktop) • the related user interfaces are either started • via a shortcut from the desktop (e.g SCOL UserInterface on the SCOL machine)or • from the PVSS Project Administration Console (.e.g. ATLASPixDCS_ELMB_userInterface on the PP2 machine) • before going home, stop the user interfaces and always Log Off (this cleans up things properly)

  20. ELMB Integration

  21. Construction kit of DCS crates • A DCS crate (e.g. SC-OLink, BBIM etc..) consists of 3-6 identical building blocks, which are installed in one 19“ crate • boss of each block is an ELMB for control and communication • Add-on cards (e.g. ‚I-Box‘, SC-OL card) are the workers • Input/output signals are distributed by fitting front/backpanel • CANbus is internally connected in serial to all CANnodes

  22. ELMB naming scheme blocks of DCS crates(= ELMB = CANnode) are reflected in the DCS naming scheme: Rack nr. (A2: USA counting room, S2: US counting room, X..: ATLAS cavern) Y3303X1_BBIM03A Y1214A2_SC06C Y1406S2_LV_PP4_08C Crate type crate and block nr Exception PP2 crates’ namings: PP2_AP2_621 A or C side, platform 1…6, box nr xx

  23. Definition of a CANbus Start menu (2) Apply changes! Creates the internal PVSS datapoints (3) Proceed with ELMB definition (1) Define a name (CAN0), the type of interface (always KV) and the number of the CAN (0). Don‘t try to change the name of a CANbus or node! Remove it and define a new one.

  24. ELMB definition 2 3 • Define - Name of ELMB- CAN to which it is connected- Node id- ELMB type • Apply changes (creates internal datapoints) • Prepare internal configuration for OPC communication • Store configuration and restart OPCserver 4 5 6 1

  25. ELMB Control (including introduction to different DCS crates)

  26. ELMB section ELMB section will be found in all ELMB based DCS devices ELMB section state running√ stopped (on purpose) Pre-operational: ADC not working disconnected: cable missing, wrong ELMB node id etc.. disconnected (OPC): OPC client or Server dead Pixel standard settings ≠0 !! Network Management

  27. Building Block Interlock & Monitor • monitors the temperatures of detector modules, opto boards and PP2 crates, using 10 kΩ NTCs • 1 crates consists of 4 BBIM, each owning 4 ‚I-Boxes‘ • I-Box creates interlock signals when temperature level is exceeded (40 °C for detector modules a. opto boards, 60 °C PP2 crates) • Location at PP3 BBIM back BBIM front

  28. BBIM ELMB section Monitoring section Temperature reading Vref for the NTCs: 2.5V Current of I-Box To create a test interlock signal via digital output port Black field: OPC quality bit is bad, no actual value or value very close to zero

  29. PP3 Power The one with the blue LEDs, indicating that the channel is operating Powers NTCs and Iboxes of BBIM One channel / BBIM crate ELMB for monitoring only To check Vmon/Imon with a DVM Front view of the PP3 PS

  30. PP3 power crate typically 12 Vcurrent < 500 mA depending on the load int. supply voltage for ELMB should be 3.3 V!

  31. Building Block Monitoring Little brother of BBIM: 2 blocks for temperature monitoring + 1 block for humidity monitoring (still in work) Connected to temperature sensors (NTC) distributed in the pixel volume Temperature values Vref for the NTCs: 2.5 V Derived from the CAN power, no separate PS Panel of a BBM temperature monitoring block

  32. LV-PP4 Front of LV-PP4 • Splits Vdd and Vdda coming from a Wiener LV power supply onto 7 lines • Consists of 3 identical blocks, each block can handle 4 Wiener channels • Measures current per line(Imon up to 3 A, calibrated up to 2 A, rms < 5 mA) • For debugging purposes also the current in the return line can be measured, when a second opto isolator card is added Backpanel of LV-PP4

  33. LV-PP4 1 Wiener channel, return current is not measured • screenshot Current measurement per channel, Zero suppression (Imon < 10 mA)sum is a calculated value int. supply voltage for ELMB should be 3.3 V!

  34. Supply and Control for the OptoLink • Power supply system for the opto boards • Provides Vpin, Viset and Rst-Opto via opto PP3 to the opto boards • Provides Vvdc via the regulator station to the opto boards • SC-OLink crate consists of 4 blocks, each powering 4 opto boards Vpin (20V, 20 mA) Viset (5V, 20 mA) Vvdc (10V, 800 mA) Rst-Opto

  35. SC-OLink To toggle between on/off Voltage/current monitoring value nominal value Status ERROR, if nominal condition differs from the actual one Acts on all 3 voltages of 1 SC-OLink channel

  36. Regulator Station ‘PP2’ • The remotely controlled regulator station is located at patch panel 2 (PP2, inside the muon chambers) • One regulator station can house up to 12 regulator boards, each board provides Vdd and Vdda for a half stave and Vvdc for the related opto board • In the middle of each regulator station a controller card is installed, which provides control via a FPGA and communication to the outer world via CAN interface of ELMB • Input voltage to the regulator channels is provided by the WIENER LV crates • Controller requires +/- 15 V, this is also provided by some specially configured Wiener powers supplies (but installed in a different crate and controlled by a separate PVSS project)

  37. Integration of PP2 Boards installed in the PP2 crate Version of regulator board, normally 4 Besides the standard integration parameters

  38. Control Panel of PP2 PP2 station S21 ELMB section channel board crate Msg field 12 boards are defined, selection of boards via tab, board 8 is shown

  39. Channel commands Make sure that the channel you want to control is powered! (Wiener/SC-OLink) Only if the channel is powered it is ensured that the commands are executed and the PP2 panel shows the actual state of the PP2 crate! To check if the channel is powered have a look into the SIT. The detector unit to which the board corresponds can easily be found out via the toolTipText of the ChannelName. • Channel can be turned on/off • Desired voltage can be set 1.5 -2.5 V for Vdd, Vdda 1.9 to 3.1 V for Vvdc • Monitor values (If no unit is displayed the channel is not marked as “calibrated” and possibly pure ADC counts are displayed)

  40. Board commands 2 temperatures/board measured, as well as Vref. Kill/Unkill: A “killed” board has no output voltage, but if the board is unkilled again the inhibit-state will determine if there is an output voltage or not. (see next slide) “Trimmers” button. To set the default voltages for all channels of this board. (The default trimmer positions can be checked in the Calibration panel). “Off”/“On”: inhibits/uninhibits all channels of this board. (a series of 16 single commands)

  41. killed PP2 board A channel which is uninhibited ON(K) will deliver a voltage as soon as the board is unkilled, OFF(K) will stay off after unkill

  42. ‚high speed‘ Crate commands • consist each of one internal PP2-command: • Kill/Unkill: Kill or Unkill all boards of the PP2 station • GU (“General Uninhibit”): uninhibit all channels of all boards • Min: sets all the Trimmers of all the boards to the Minimum

  43. Composed crate commands • combinations of internal PP2-commands, therefore more time-consuming. • Reset: was intended to synchronize PP2 and PVSS. Should normally not be used. (double click). It sends the PP2commands KillAll/GU/Min, and starts the readout for all boards. • Recover: will KillAll, then set the values known to PVSS (Inhibit, Vset) and start the readout for all boards. • Inh: will Inhibit all channels of all boards • Init: will KillAll, Inhibit all channels and set all the Trimmers to default • Cal: will open the Calibration panel for all the crates defined on this system • GoMin/Direct: determines how the Trimmers are set. If the button shows “GoMin” the Trimmer will be set to the Minimum and afterwards to the Trimmer position corresponding to the desired voltage. If the button shows “Direct” than the necessary steps to reach the new trimmer position is calculated from the previous trimmer position and set directly. “GoMin” should be used if one suspects that the trimmer position of PP2 crate and PVSS is not synchronized. But since these are two commands and the total number of trimmer steps moved is larger, this will take more time than in “direct mode”

  44. ELMB section PDO routine inside ELMB responsible of reading of values During command execution: PDO should inactive, (white)PP2 mode: 0 Blue: PDO is active white. PDO is inactive The Regulator ELMB has no NodeGuarding, under construction state: alive or not responding 128! green: board is readout yellow: no readout white: board not defined Red: board is killed To change the above settings, start child panel PDO (process data object): for exchange of process data inside CANopen =0! Start!

  45. Setting of the PDO routine For changing which boards are read out/killed, click the corresponding squares. If the pattern matches the desired one, the button “ReadOut” or “Kill” must be pressed. After every power cycle of the controller the ReadOut-Pattern must be sent! Otherwise no board will be read out and no values sent to PVSS, even if the routine is running. Stop/start of PDO routine

  46. Execution of commands Command execution in progress If the panel gets “stuck”

  47. Watchdog • Each standard (non PP2) ELMB has its watchdog, starts barking when ELMB does not send heart beat • If the watchdog is happy, ELMB is alive, OPC server and client are working properly Work on watchdogs still ongoing!

  48. CAN PSU

  49. CAN PSU CAN PSU provides 2 voltages/CANbus: • Vcan for the CAN controller • Vad for the analogue and digital circuits of the ELMB Front view of 2 CAN PSUs

  50. CAN PSU Standard CERN software used: fw (frame work) (2) Double click here, gives you the monitoring panel on the next slide (1) In the starting panel (left) you can select the ELMBs controlling the CAN PSU Right: 2 ELMBs for 2 crates are displayed