1 / 48

Construction Plan Review and Facility Design in Food Service

Learn about the importance of reviewing construction plans, designing a well-structured kitchen layout, choosing the right flooring and interior finishes, and meeting requirements for restrooms and handwashing stations in food service facilities.

rledesma
Download Presentation

Construction Plan Review and Facility Design in Food Service

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Objectives • Identify the following: • When a review of the construction plan is required • Characteristics of correct flooring • Characteristics of correct interior finishes, including doors, walls, and ceilings • Requirements for restrooms • Requirements for handwashing stations • Requirements for food-contact surfaces 11-2

  2. Objectives • Identify the following: • Organizations that certify equipment that meets sanitation standards • Requirements for dishwashing facilities • Requirements for installing equipment • Approved water sources and testing requirements • Methods for preventing cross-connection and backflow • The correct response to a wastewater overflow 11-3

  3. Objectives • Identify the following: • Lighting-intensity requirements for different areas of the operation • Ways of preventing lighting sources from contaminating food • Ways of preventing ventilation systems from contaminating food and food-contact surfaces • Requirements for handling garbage, including correct storage and removal • The importance of keeping physical facilities in good repair 11-4

  4. Construction Plan Review • Construction plans will require approval by the local regulatory authority. • Benefits of a regulatory review: • Ensures design meets regulatory requirements • Ensures safe flow of food • May save time and money • Ensures contractors are constructing the facility correctly • Ensures approved equipment is being used • 11-5

  5. Layout • A well-designed kitchen will address: • Workflow • Minimizes the time food spends in the temperature danger zone • Minimizes the number of times foodis handled • 11-6

  6. Layout • A well-designed kitchen will address: • Contamination • Layout minimizes the risk of cross-contamination • Equipment is placed to prevent splashing or spillage • Equipment accessibility • Equipment is placed so staff can easily clean the facility and all equipment • 11-7

  7. Flooring Flooring must be: • Smooth • Durable • Nonabsorbent • Easy to clean • Wear-resistant • Slip-resistant Porosity: The extent to which a material will absorb liquids. • 11-8

  8. Flooring To prevent problems, use nonabsorbent flooring in these areas: • Walk-in coolers • Prep and food-storage • Dishwashing • Restrooms • Dressing and locker rooms • 11-9

  9. Flooring Nonporous, resilient flooring: • Advantages • Relatively inexpensive • Easy to clean and maintain • Wears well • Resists grease and alkalis • Disadvantages • Easily damaged • Slippery when wet • 11-10

  10. Flooring Hard-surface flooring: • Advantages • Durable • Nonabsorbent • May be slip-resistant • Disadvantages • Easily damaged • Does not absorb sound • Expensive to install and maintain • May be difficult to clean • May be slippery • 11-11

  11. Flooring Carpeting: • Advantages • Sound absorbent • Easy to maintain • Disadvantages • Not good for high-dirt areas • May require routine cleaning • 11-12

  12. Flooring Special flooring needs: • Use nonslip surfaces in traffic areas. • Ideal for the entire kitchen • Rubber mats can be used where standing water may occur. • Coving is required for resilient or hard-surface flooring materials. • Makes cleaning easier • Eliminates hiding places for pests • Reduces moisture damage to walls • 11-13

  13. Finishes for Interior Walls and Ceilings Materials for interior walls and ceilings: • Smooth • Nonabsorbent • Durable • Easy to clean • 11-14

  14. Dry Storage Dry storage design and construction: • Easy-to-clean materials that • Allow good air circulation • Are made of corrosion-resistant metal or food-grade plastic • No direct sunlight • No steam pipes, water lines, or other conduits • Fill cracks and crevices in floors and walls • Use self-closing doors • Use screens on windows and doors • 11-15

  15. Handwashing Stations Handwashing stations must be: • Conveniently located • Located in: • Restrooms or directly next to them • Food-prep areas • Service areas • Dishwashing areas 11-16

  16. Handwashing Stations Handwashing stations must be: • Used only for handwashing • Installed with adequate barriers or distance from food and food-contact surfaces • Working correctly • Well stocked and maintained • Available at all times • Do not block them X 11-17

  17. Handwashing Stations • Signage • Garbage container • A way to dry hands • Soap • Hot and cold running water • Handwashing stations must have: 11-18

  18. Sinks To prevent cross-contamination: • Use sinks only for their intended purpose • Handwashing sinks • Prep sinks • Service sinks • At least one service sink is required 11-19

  19. Restrooms Restrooms should be: • Separate for staff and guests when possible • If restrooms are shared, operations must be designed so guests do not pass through prep areas • Convenient • Sanitary • Equipped with self-closing doors • Adequately stocked • Provided with garbage containers 11-20

  20. Dressing Rooms and Lockers If dressing rooms and lockers are used: • Do not use dressing rooms for food prep, storage, or utensil washing. • Locate lockers in a separate room or one where food, equipment, utensils, linens, and single-service items cannot be contaminated. 11-21

  21. Premises Design of premises: • Ensure parking lots and walkways are • Graded to prevent standing water • Surfaced to minimize dirt and dust • No guest traffic through prep areas • No living or sleeping quarters 11-22

  22. Equipment Standards • Look for the NFS mark when purchasing equipment: • Ensures food equipment surfaces are • Nonabsorbent • Smooth • Corrosion resistant • Easy to clean • Durable • Resistant to damage • 11-23

  23. Dishwashing Machines • Commonly used types of dishwashers: • Single-tank, stationary-rack machine, with doors • Conveyor machine • Carousel or circular-conveyor machine • Flight type • Batch-type, dump • Recirculating, door-type, non-dump machine 11-24

  24. Dishwashing Machines • Dishwashers must be installed: • So they are reachable and conveniently located • So utensils, equipment, and other food-contact services do not become contaminated • At least six inches (15 centimeters) off the floor to permit easy cleaning beneath • Following manufacturer’s instructions • So water pipes to the machine are as short as possible to prevent heat loss 11-25

  25. Dishwashing Machines • When selecting dishwashers make sure: • The detergents and sanitizers used are approved by the local regulatory authority. • They can measure water temperature, water pressure, and cleaning and sanitizing chemical concentration. • Information about the correct settings is posted on the machine. • The machine’s thermometer is the following. • Located where it’s readable • Has increments no greater than 2ºF (1ºC) • The machine is easy to clean. 11-26

  26. Three-Compartment Sinks Purchase sinks large enough to accommodate large equipment and utensils. 11-27

  27. Coolers and Freezers • Considerations for purchasing and installing coolers and freezers: • Doors should withstand heavy use. • A drain must be provided for defrosting. • Units must installed correctly. • Walk-ins—Sealed to the floor and wall • Reach-ins—Elevated six inches (15 centimeters) off the floor or mounted and sealed on a masonry base 11-28

  28. Coolers and Freezers • Considerations for purchasing and installing coolers and freezers: • The unit must meet the temperature requirements. • Built-in thermometers should be the following. • Easy to locate and read • Accurate to within ±3ºF or ±1.5ºC 11-29

  29. Blast Chillers and Tumble Chillers • Blast chillers: • Many allow target food temperatures to be set. • Many can monitor food temperatures. Tumble chillers: • Cool prepackaged food inside a drum that rotates in chilled water. 11-30

  30. Cook-Chill Equipment • Cook-chill equipment: • An integrated piece of equipment that can cook, cool, and reheat food. 11-31

  31. Cutting Boards • Cutting boards: • May be wooden or synthetic • Wooden cutting boards and baker’s tables must be • Allowed by the regulator authority • Made from a nonabsorbent hardwood • Nontoxic • Free of cracks and seams 11-32

  32. Installing Kitchen Equipment Floor-mounted equipment must be either: • Mounted on legs at least six inches (15 centimeters) high • Sealed to a masonry base 11-33

  33. Installing Kitchen Equipment Tabletop equipment should be either: • Mounted on legs at least four inches (10 centimeters) high • Sealed to the countertop 11-34

  34. Maintaining Equipment • Once equipment has been installed: • It must be maintained regularly. • Only qualified people should maintain it. • Set up a maintenance schedule with your supplier or manufacturer. • Check equipment regularly to make sure it is working correctly. 11-35

  35. Water Supply • Acceptable sources of drinkable (potable) water: • Approvedpublic water mains • Regularly tested and maintained private sources • Closed, portable water containers • Water transport vehicles 11-36-

  36. Water Supply • Ensure a continuous supply of hot water: • Evaluate water heaters often. • Consider how quickly the heater produces hot water. • Consider a booster heater for hot-water sanitizing. 11-37

  37. Water and Plumbing • Cross-connection: • Physical link between safe water and dirty water from • Drains • Sewers • Other wastewater sources 11-38

  38. Water and Plumbing Backflow: • Reverse flow of contaminants through a cross-connection into the drinkable water supply. Backsiphonage: • A vacuum created in the plumbing system that sucks contaminants back into the water supply. • Can occur when high water use in one area of the operation creates a vacuum • A running hose in a mop bucket can lead to backsiphonage 11-39

  39. Water and Plumbing • Backflow prevention methods: • Air gap • Vacuum breaker 11-40

  40. Water and Plumbing • Grease condensation and leaking pipes: • Grease traps can be installed to prevent grease from blocking drains. • Grease traps must be the following. • Installed by a licensed plumber • Easy to access • Cleaned regularly 11-41

  41. Sewage Ifthere is a backup of sewage in the operation: • The affected area should be closed right away. • The problem must be corrected. • The area must be thoroughly cleaned. If the backup is a significant risk to food safety: • Service must be stopped. • The local regulatory authority must be notified. 11-42

  42. Lighting • Consider the following when installing and maintaining lighting: • Different areas of the facility have different lighting intensity requirements. • Local jurisdictions usually require prep areas to be brighter than other areas. • All lights should have shatter-resistant lightbulbs or protective covers. • Replace burned out bulbs with correct size bulbs. 11-43

  43. Lighting • Minimum lighting intensity by area: 11-44

  44. Ventilation • Ventilation systems: • Improve air quality • Reduce grease and condensation buildup • Must be cleaned and maintained • Must be used in cooking, frying, and grilling areas • Must NOT drip onto food or equipment 11-45

  45. Garbage • Removal and cleaning: • Remove garbage from prep areas as quickly as possible. • Be careful not to contaminate food and food-contact surfaces. • Clean the inside and outside of garbage containers frequently. • Clean them away from food-prep and storage areas. 11-46

  46. Garbage Indoor containers must be: • Leakproof, waterproof, and pestproof • Easy to clean • Covered when not in use Designated storage areas: • Store waste and recyclables away from food and food-contact surfaces. • Storage must not create a nuisance or a public health hazard. 11-47

  47. Garbage Outdoor containers must: • Be placed on a smooth, durable, nonabsorbent surface • Asphalt or concrete • Have tight-fitting lids • Be covered at all times • Have their drain plugs in place 11-48

More Related