1 / 34

Database Converter (NS1000 Off line mode V2.0)

A powerful off-line programming tool that converts system data of NCP/TDE/TDA series PBX into data for NS1000. Supports platform replacement and legacy database conversion.

perezl
Download Presentation

Database Converter (NS1000 Off line mode V2.0)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Database Converter (NS1000 Off line mode V2.0) Rev1.0 04 Mar., 2013

  2. Over view

  3. DGSYS DBSYS DMSYS DLSYS DCSYS Database Converter (NS1000 Off line mode V2.0) Over view 1/3 The off-line programming tool provides legacy database converter feature that can convert system data of NCP/TDE/TDA series PBX into data for NS1000. Off line tool (V2.0) UPCMC (PBX Replacement) NS1000 is overwritten in new DCSYS. TDE100 /200 Edit Convert report TDE600 NCP500 /1000 TDA100 /200 DSYS NS1000 TDA600 Activation key is not transferred at the converting database TDE/NCP TDA The data of TDA should convert it into the data of TDE in UPCMC. Then it can be used for conversion into the data of NS1000.

  4. TDA/TDE/NCP not used Database Converter (NS1000 Off line mode V2.0) Over view 2/3 The feature supports 2 functionalities as follows. • Platform Replacement (TDE/NCP->NS1000) • Legacy database converter for replacing to NS1000 from legacy PBX • The target data of convert is the data of only IP Trunk and IP terminal. The data of a physical IP-GW card is not converted. IP Trunk V-IPGW16,V-SIPGW16 IP Trunk V-IPGW16,V-SIPGW16 IP-GW4,16 It’s not supported. NS1000 TDA/TDE/NCP IP terminal V-IPEXT32 V-SIPEXT32 V-IPCS4 IP-EXT16 (Physical card) IP terminal V-IPEXT32 V-SIPEXT32 V-IPCS4

  5. Database Converter (NS1000 Off line mode V2.0) Over view 3/3 2) Platform As Legacy GW Data (TDE/NCP->NS1000+Legacy GW) Legacy database converter for using existing PBX as legacy gateway. Of course, data related to IP is converted like case “1) Platform Replacement”. IP Trunk V-IPGW16,V-SIPGW16 IP Trunk V-IPGW16,V-SIPGW16 IP-GW4,16 It’s not supported. STACK-M Legacy Trunk Legacy Trunk TDA/TDE/NCP STACK-S PS can be used without re-registration. IP terminal V-IPEXT32 V-SIPEXT32 V-IPCS4 IP-EXT16 (Physical card) DPT/SLT DPT/SLT IP terminal V-IPEXT32 V-SIPEXT32 V-IPCS4

  6. Condition

  7. Database Converter (NS1000 Off line mode V2.0) Condition 1/7 The database converter is a part of application in off-line programming software and it is initiated by clicking the icon on launcher of the off-line programming. Note: Not support to convert via Web-MC (On-line) The following table shows target series of PBX and the version number to be converted. *1: Database file has to be converted into DGSYS or DMSYS of KX-TDE by using data replacement application on PCMC before the legacy database convertor.

  8. Database Converter (NS1000 Off line mode V2.0) Condition 2/7 Mode: Platform Replacement (TDE/NCP->NS1000) The following table shows which programming items can be converted *1: Include Extension number, Extension name, FF key data *2: Only support IP Extension and PS/IP-PS *3: Include Trunk number *4: IP trunk of IP-GW card is not supported.

  9. Database Converter (NS1000 Off line mode V2.0) Condition 3/7 Mode: Platform As Legacy GW Data (TDE/NCP->NS1000+Legacy GW) *1: Include Extension number, Extension name, FF key data *2: Include Trunk number

  10. Database Converter (NS1000 Off line mode V2.0) Condition 4/7 Available converting patterns pattern 1 (Replacement:Only IP) NS1000 TDA/TDE/NCP pattern 2 (Included Legacy) Please connect existing PBX with Legacy GW1. NS1000 TDA/TDE/NCP Legacy GW1 TDA/TDE/NCP pattern 3 Converting database of TDE/TDA multi cabinet to legacy gateway units. TDE620 TDE600 NS1000 Legacy GW2 Shelf 2 Legacy GW1 Shelf 1 TDE600 TDE620 TDE600 TDE620 Shelf 1 Shelf 2

  11. Database Converter (NS1000 Off line mode V2.0) Condition 5/7 Available converting patterns pattern 4 Converting database of TDE/TDA multi cabinet to legacy gateway units on NS1000 slave units. One Look Networking Master Slave NS1000 NS1000 Shelf 4 Legacy GW2 Legacy GW2 Legacy GW1 Legacy GW1 Shelf 3 TDA620 TDA620 TDE620 TDE600 Shelf 2 Shelf 1 Shelf 3 Shelf 4 Shelf 1 Shelf 2 The shelf location is fixed.

  12. TDA/TDE/NCP TDA/TDE/NCP Database Converter (NS1000 Off line mode V2.0) Condition 6/7 Unavailable converting patterns pattern 1 Master NS1000 TDA/TDE/NCP Legacy GW2 Legacy GW1 TDA/TDE/NCP TDA/TDE/NCP TDA/TDE/NCP Multi system One Look Networking Master Slave NS1000 NS1000 This tool doesn't support data conversion of the multi system. Legacy GW1 Legacy GW1

  13. Database Converter (NS1000 Off line mode V2.0) Condition 7/7 Unavailable converting patterns One Look Networking pattern 2 Master Slave NS1000 NS1000 Legacy GW1 TDA/TDE/NCP TDA/TDE/NCP This tool doesn't support the data conversion connected with the slave. pattern 3 NS1000 Legacy GW2 TDA/TDE/NCP TDA/TDE/NCP This tool doesn't support the data conversion connected with the Legacy GW2.

  14. Database Converter (NS1000 Off line mode V2.0) Table of item not converted 1/3 The converted value is indicated in right column

  15. Database Converter (NS1000 Off line mode V2.0) Table of item not converted 2/3

  16. Database Converter (NS1000 Off line mode V2.0) Table of item not converted 3/3

  17. Database Converter (NS1000 Off line mode V2.0) Unavailable cards 1/1 Following components can not be used with Legacy-GW. These data is deleted. *1: The data of IP extension is taken over to a virtual extension card.

  18. Database Converter (NS1000 Off line mode V2.0) Note 1/1 -TDADatabase (DSYS and DLSYS) file has to be converted into DGSYS or DMSYS of KX-TDE by using data replacement application on PCMC before the legacy database convertor. -New program items added in NS1000 are filled by the default value. -All data of numbering plan are switched to originated (New DCSYS) data since the default values are different between NS1000 and other PBXs. -New setting of dial plan added in NS1000, which is not in legacy PBXs, are filled with BLANK. -OPB card and any card on OPB card are not supported to convert. -Activation key is not transferred at the converting database.

  19. DGSYS DBSYS DMSYS Database Converter (NS1000 Off line mode V2.0) Procedure of conversion 1/7 Converter type needs to be selected from the following 2 types at initiation of converter application. 1) Replacement 2) Legacy Gateway After this selection, some of mandatory system setting need to be programmed, then DCSYS file for NS1000 is created automatically. Convert NS1000 Off line V2.0 or or

  20. Database Converter (NS1000 Off line mode V2.0) Procedure of conversion 2/7 It depends on data before it converts it then the composition chart is shown. For TDA/E600, and TDA/E620 when the slave is connected For NCP, TDA/E100, and TDA/E200

  21. Database Converter (NS1000 Off line mode V2.0) Procedure of conversion 3/7 A part of region should change the setting. Please refer to P26. Parametes and operation is completely same as Easy Setup wizard. P22 (When the slave is connected) IP addresses, type of registration and password, etc programmed on TDE/NCP are displayed by default. Converting time is estimated to take with in 10 seconds P23 (Case with TDE100/200/NCP)

  22. Database Converter (NS1000 Off line mode V2.0) Procedure of conversion 4/7 This operation is required in case source database file contains an more than 3 expansion unit setting of TDA/E600/620. P23 Converting time is estimated to take with in 10 seconds

  23. Database Converter (NS1000 Off line mode V2.0) Procedure of conversion 5/7 When the conversion of data is completed, the report of the result is displayed. Example Following Recommended A.K Deleted Card Activation key is not transferred at the converting database

  24. Database Converter (NS1000 Off line mode V2.0) Procedure of conversion 6/7 The following three steps can be selected. DCSYS The name is given to the new data. (DCSYS) Finish And, converted DCSYS is downloaded. Open Offline mode Connection Online Mode

  25. Database Converter (NS1000 Off line mode V2.0) Procedure of conversion 7/7 Please transfer (Installation) the “converted DCSYS” on Online mode. C:\Documents- - - -DCSYS The reset operation is necessary.

  26. Database Converter (NS1000 Off line mode V2.0) Suffix Code 1/1 Please change the setting to the area shown in the following tables. Legacy gateway NS1000 In area other than this table, the change is unnecessary.

  27. Database Converter (NS1000 Off line mode V2.0) Result of Converting 1/2 The following results are displayed when data conversion is completed. It might be effective help to make the New Configuration of NS1000. These contents are examples. Recommended AK is displayed. Both the deleted extension number and the deleted CO number are described. OPB card and any card on OPB card are not supported to convert.

  28. Database Converter (NS1000 Off line mode V2.0) Result of Converting 2/2 Two IP-EXT16 cards were integrated into one V-IPEXT32 card.

  29. END

  30. Appendix

  31. Database Converter (NS1000 Off line mode V2.0) Appendix : Supported PBX model Application model (1/1) KX-NS1000 allows connecting following system for legacy gateway system. It means “The data of the application model is convertible “.

  32. DGSYS DGSYS Database Converter (NS1000 Off line mode V2.0) Appendix : Change of version of DSYS from V4 to V6 Change of version of DSYS (1/1) Please use version 6 or late of UPCMC. Example V4 V6

  33. Database Converter (NS1000 Off line mode V2.0) Appendix : Suffix Table Suffix Code and Area table. (1/2) Please select the Area on the converter.

  34. Database Converter (NS1000 Off line mode V2.0) Appendix : Suffix Table Suffix Code and Area table. (2/2) Please select the Area on the converter.

More Related